Search results for: thread retrieval
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 392

Search results for: thread retrieval

2 Challenging Airway Management for Tracheal Compression Due to a Rhabdomyosarcoma

Authors: Elena Parmentier, Henrik Endeman

Abstract:

Introduction: Large mediastinal masses often present with diagnostic and clinical challenges due to compression of the respiratory and hemodynamic system. We present a case of a mediastinal mass with symptomatic mechanical compression of the trachea, resulting in challenging airway management. Methods: We present a case of 66-year-old male, complaining of progressive dysphagia. Initial esophagogastroscopy revealed a stenosis secondary to external compression, biopsies were inconclusive. Additional CT scan showed a large mediastinal mass of unknown origin, situated between the vertebrae and esophagus. Symptoms progressed and patient developed dyspnea and stridor. A new CT showed quick growth of the mass with compression of the trachea, subglottic to just above the carina. A tracheal covered stent was successfully placed. Endobronchial ultrasound revealed a large irregular mass without tracheal invasion, biopsies were taken. 4 days after stent placement, the patients’ condition deteriorated with worsening of stridor, dyspnea and desaturation. Migration of the tracheal stent into the right main bronchus was seen on chest X ray, with obstruction of the left main bronchus and secondary atelectasis. Different methods have been described in the literature for tracheobronchial stent removal (surgical, endoscopic, fluoroscopyguided), our first choice in this case was flexible bronchoscopy. However, this revealed tracheal compression above the migrated stent and passage of the scope occurred impossible. Patient was admitted to the ICU, high-flow nasal oxygen therapy was started and the situation stabilized, giving time for extensive assessment and preparation of the airway management approach. Close cooperation between the intensivist, pulmonologist, anesthesiologist and otorhinolaryngologist was essential. Results: In case of sudden deterioration, a protocol for emergency situations was made. Given the increased risk of additional tracheal compression after administration of neuromuscular blocking agents, an approach with awake fiberoptic intubation maintaining spontaneous ventilation was proposed. However, intubation without retrieval of the tracheal stent was found undesirable due to expected massive shunting over the left atelectatic lung. As rescue option, assistance of extracorporeal circulation was considered and perfusionist was kept on standby. The patient stayed stable and was transferred to the operating theatre. High frequency jet ventilation under general anesthesia resulted in desaturations up to 50%, making rigid bronchoscopy impossible. Subsequently an endotracheal tube size 8 could be placed successfully and the stent could be retrieved via bronchoscopy over (and with) the tube, after which the patient was reintubated. Finally, a tracheostomy (Shiley™ Tracheostomy Tube With Cuff, size 8) was placed, fiberoptic control showed a patent airway. Patient was readmitted to the ICU and could be quickly weaned of the ventilator. Pathology was positive for rhabdomyosarcoma, without indication for systemic therapy. Extensive surgery (laryngectomy, esophagectomy) was suggested, but patient refused and palliative care was started. Conclusion: Due to meticulous planning in an interdisciplinary team, we showed a successful airway management approach in this complicated case of critical airway compression secondary to a rare rhabdomyosarcoma, complicated by tracheal stent migration. Besides presenting our thoughts and considerations, we support exploring other possible approaches of this specific clinical problem.

Keywords: airway management, rhabdomyosarcoma, stent displacement, tracheal stenosis

Procedia PDF Downloads 65
1 Interference of Polymers Addition in Wastewaters Microbial Survey: Case Study of Viral Retention in Sludges

Authors: Doriane Delafosse, Dominique Fontvieille

Abstract:

Background: Wastewater treatment plants (WWTPs) generally display significant efficacy in virus retention yet, are sometimes highly variable, partly in relation to large fluctuating loads at the head of the plant and partly because of episodic dysfunctions in some treatment processes. The problem is especially sensitive when human enteric viruses, such as human Noroviruses Genogroup I or Adenoviruses, are in concern: their release downstream WWTP, in environments often interconnected to recreational areas, may be very harmful to human communities even at low concentrations. It points out the importance of WWTP permanent monitoring from which their internal treatment processes could be adjusted. One way to adjust primary treatments is to add coagulants and flocculants to sewage ahead settling tanks to improve decantation. In this work, sludge produced by three coagulants (two organics, one mineral), four flocculants (three cationic, one anionic), and their combinations were studied for their efficacy in human enteric virus retention. Sewage samples were coming from a WWTP in the vicinity of the laboratory. All experiments were performed three times and in triplicates in laboratory pilots, using Murine Norovirus (MNV-1), a surrogate of human Norovirus, as an internal control (spiking). Viruses were quantified by (RT-)qPCR after nucleic acid extraction from both treated water and sediment. Results: Low values of sludge virus retention (from 4 to 8% of the initial sewage concentration) were observed with each cationic organic flocculant added to wastewater and no coagulant. The largest part of the virus load was detected in the treated water (48 to 90%). However, it was not counterbalancing the amount of the introduced virus (MNV-1). The results pertained to two types of cationic flocculants, branched and linear, and in the last case, to two percentages of cations. Results were quite similar to the association of a linear cationic organic coagulant and an anionic flocculant, though suggesting that differences between water and sludges would sometimes be related to virus size or virus origins (autochthonous/allochthonous). FeCl₃, as a mineral coagulant associated with an anionic flocculant, significantly increased both auto- and allochthonous virus retention in the sediments (15 to 34%). Accordingly, virus load in treated water was lower (14 to 48%) but with a total that still does not reach the amount of the introduced virus (MNV-1). It also appeared that the virus retrieval in a bare 0.1M NaCl suspension varied rather strongly according to the FeCl₃ concentration, suggesting an inhibiting effect on the molecular analysis used to detect the virus. Finally, no viruses were detected in both phases (sediment and water) with the combination branched cationic coagulant-linear anionic flocculant, which was later demonstrated as an effect, here also, of polymers on the virus detection-molecular analysis. Conclusions: The combination of FeCl₃-anionic flocculant gave its highest performance to the decantation-based virus removal process. However, large unbalanced values in spiking experiments were observed, suggesting that polymers cast additional obstacles to both elution buffer and lysis buffer on their way to reach the virus. The situation was probably even worse with autochthonous viruses already embedded into sewage's particulate matter. Polymers and FeCl₃ also appeared to interfere in some steps of molecular analyses. More attention should be paid to such impediments wherever chemical additives are considered to be used to enhance WWTP processes. Acknowledgments: This research was supported by the ABIOLAB laboratory (Montbonnot Saint-Martin, France) and by the ASPOSAN association. Field experiments were possible thanks to the Grand Chambéry WWTP authorities (Chambéry, France).

Keywords: flocculants-coagulants, polymers, enteric viruses, wastewater sedimentation treatment plant

Procedia PDF Downloads 94