Search results for: bending rectangular plates
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1353

Search results for: bending rectangular plates

3 Speciation of Bacteria Isolated from Clinical Canine and Feline Urine Samples by Using ChromID CPS Elite Agar: A Preliminary Study

Authors: Delsy Salinas, Andreia Garcês, Augusto Silva, Paula Brilhante Simões

Abstract:

Urinary tract infection (UTI) is a common disease affecting dogs and cats in both community and hospital environment. Bacteria is the most frequent agent isolated, fewer than 1% of infections are due to parasitic, fungal, or viral agents. Common symptoms and laboratory abnormalities includeabdominal pain, pyrexia, renomegaly, and neutrophilia with left shift. A rapid and precise identification of the bacterial agent is still a challenge in veterinarian laboratories. Therefore, this cross-sectional study aims to describe bacterial colony patterns of urine samples by using chromID™ CPS® EliteAgar (BioMérieux, France) from canine and feline specimens submitted to a veterinary laboratory in Portugal (INNO Veterinary Laboratory, Braga)from January to March2022. All urine samples were cultivated in CPS Elite Agar with calibrated 1 µL inoculating loop and incubated at 37ºC for 18-24h. Color,size, and shape (regular or irregular outline)were recorded for all samples. All colonies were classified as Gram-negative or Gram-positive bacteriausing Gram stain (PREVI® Color BioMérieux, France) and determined if they were pure colonies. Identification of bacteria species was performed using GP and GN cards inVitek 2® Compact(BioMérieux, France). A total of 256/1003 submitted urine samples presented bacterial growth, from which 172 isolates were included in this study. The sample’s population included 111 dogs (n=45 males and n=66 females) and 61 cats (n=35 males and n=26 females). The most frequent isolated bacteria wasEscherichia coli (44,7%), followed by Proteus mirabilis (13,4%). All Escherichia coli isolates presented red to burgundy colonies, a colony diameter between 2 to 6 mm, and regular or irregular outlines. Similarly, 100% of Proteus mirabilis isolates were dark yellow colonies with a diffuse pigment and the same size and shape as Escherichia coli. White and pink pale colonies where Staphylococcus species exclusively and S. pseudintermedius was the most frequent (8,2 %). Cian to blue colonies were mostly Enterococcusspp. (8,2%) and Streptococcus spp. (4,6%). Beige to brown colonies were Pseudomonas aeruginosa (2,9%) and Citrobacter spp. (1,2%).Klebsiella spp.,Serratia spp. and Enterobacter spp were green colonies. All Gram-positive isolates were 1 to 2 mm diameter long and had a regular outline, meanwhile, Gram-negative rods presented variable patterns. This results showed that theprevalence of E coli and P. mirabilis as uropathogenic agents follows the same trends in Europe as previously described in other studies. Both agents presented a particular color pattern in CPS Elite Agar to identify them without needing complementary tests. No other bacteria genus could be correlated strongly to a specific color pattern, and similar results have been observed instudies using human’s samples. Chromogenic media shows a great advantage for common urine bacteria isolation than traditional COS, McConkey, and CLEDAgar mediums in a routine context, especially when mixed fermentative Gram-negative agents grow simultaneously. In addition, CPS Elite Agar is versatile for Artificial Intelligent Reading Plates Systems. Routine veterinarian laboratories could use CPS Elite Agar for a rapid screening for bacteria identification,mainlyE coli and P.mirabilis, saving 6h to 10h of automatized identification.

Keywords: cats, CPS elite agar, dogs, urine pathogens

Procedia PDF Downloads 66
2 3D Non-Linear Analyses by Using Finite Element Method about the Prediction of the Cracking in Post-Tensioned Dapped-End Beams

Authors: Jatziri Y. Moreno-Martínez, Arturo Galván, Israel Enrique Herrera Díaz, José Ramón Gasca Tirado

Abstract:

In recent years, for the elevated viaducts in Mexico City, a construction system based on precast/pre-stressed concrete elements has been used, in which the bridge girders are divided in two parts by imposing a hinged support in sections where the bending moments that are originated by the gravity loads in a continuous beam are minimal. Precast concrete girders with dapped ends are a representative sample of a behavior that has complex configurations of stresses that make them more vulnerable to cracking due to flexure–shear interaction. The design procedures for ends of the dapped girders are well established and are based primarily on experimental tests performed for different configurations of reinforcement. The critical failure modes that can govern the design have been identified, and for each of them, the methods for computing the reinforcing steel that is needed to achieve adequate safety against failure have been proposed. Nevertheless, the design recommendations do not include procedures for controlling diagonal cracking at the entrant corner under service loading. These cracks could cause water penetration and degradation because of the corrosion of the steel reinforcement. The lack of visual access to the area makes it difficult to detect this damage and take timely corrective actions. Three-dimensional non-linear numerical models based on Finite Element Method to study the cracking at the entrant corner of dapped-end beams were performed using the software package ANSYS v. 11.0. The cracking was numerically simulated by using the smeared crack approach. The concrete structure was modeled using three-dimensional solid elements SOLID65 capable of cracking in tension and crushing in compression. Drucker-Prager yield surface was used to include the plastic deformations. The longitudinal post-tension was modeled using LINK8 elements with multilinear isotropic hardening behavior using von Misses plasticity. The reinforcement was introduced with smeared approach. The numerical models were calibrated using experimental tests carried out in “Instituto de Ingeniería, Universidad Nacional Autónoma de México”. In these numerical models the characteristics of the specimens were considered: typical solution based on vertical stirrups (hangers) and on vertical and horizontal hoops with a post-tensioned steel which contributed to a 74% of the flexural resistance. The post-tension is given by four steel wires with a 5/8’’ (16 mm) diameter. Each wire was tensioned to 147 kN and induced an average compressive stress of 4.90 MPa on the concrete section of the dapped end. The loading protocol consisted on applying symmetrical loading to reach the service load (180 kN). Due to the good correlation between experimental and numerical models some additional numerical models were proposed by considering different percentages of post-tension in order to find out how much it influences in the appearance of the cracking in the reentrant corner of the dapped-end beams. It was concluded that the increasing of percentage of post-tension decreases the displacements and the cracking in the reentrant corner takes longer to appear. The authors acknowledge at “Universidad de Guanajuato, Campus Celaya-Salvatierra” and the financial support of PRODEP-SEP (UGTO-PTC-460) of the Mexican government. The first author acknowledges at “Instituto de Ingeniería, Universidad Nacional Autónoma de México”.

Keywords: concrete dapped-end beams, cracking control, finite element analysis, postension

Procedia PDF Downloads 194
1 Structural Characteristics of HPDSP Concrete on Beam Column Joints

Authors: Hari Krishan Sharma, Sanjay Kumar Sharma, Sushil Kumar Swar

Abstract:

Inadequate transverse reinforcement is considered as the main reason for the beam column joint shear failure observed during recent earthquakes. DSP matrix consists of cement and high content of micro-silica with low water to cement ratio while the aggregates are graded quartz sand. The use of reinforcing fibres leads not only to the increase of tensile/bending strength and specific fracture energy, but also to reduction of brittleness and, consequently, to production of non-explosive ruptures. Besides, fibre-reinforced materials are more homogeneous and less sensitive to small defects and flaws. Recent works on the freeze-thaw durability (also in the presence of de-icing salts) of fibre-reinforced DSP confirm the excellent behaviour in the expected long term service life.DSP materials, including fibre-reinforced DSP and CRC (Compact Reinforced Composites) are obtained by using high quantities of super plasticizers and high volumes of micro-silica. Steel fibres with high tensile yield strength of smaller diameter and short length in different fibre volume percentage and aspect ratio tilized to improve the performance by reducing the brittleness of matrix material. In the case of High Performance Densified Small Particle Concrete (HPDSPC), concrete is dense at the micro-structure level, tensile strain would be much higher than that of the conventional SFRC, SIFCON & SIMCON. Beam-column sub-assemblages used as moment resisting constructed using HPDSPC in the joint region with varying quantities of steel fibres, fibre aspect ratio and fibre orientation in the critical section. These HPDSPC in the joint region sub-assemblages tested under cyclic/earthquake loading. Besides loading measurements, frame displacements, diagonal joint strain and rebar strain adjacent to the joint will also be measured to investigate stress-strain behaviour, load deformation characteristics, joint shear strength, failure mechanism, ductility associated parameters, stiffness and energy dissipated parameters of the beam column sub-assemblages also evaluated. Finally a design procedure for the optimum design of HPDSPC corresponding to moment, shear forces and axial forces for the reinforced concrete beam-column joint sub-assemblage proposed. The fact that the implementation of material brittleness measure in the design of RC structures can improve structural reliability by providing uniform safety margins over a wide range of structural sizes and material compositions well recognized in the structural design and research. This lead to the development of high performance concrete for the optimized combination of various structural ratios in concrete for the optimized combination of various structural properties. The structural applications of HPDSPC, because of extremely high strength, will reduce dead load significantly as compared to normal weight concrete thereby offering substantial cost saving and by providing improved seismic response, longer spans, and thinner sections, less reinforcing steel and lower foundation cost. These cost effective parameters will make this material more versatile for use in various structural applications like beam-column joints in industries, airports, parking areas, docks, harbours, and also containers for hazardous material, safety boxes and mould & tools for polymer composites and metals.

Keywords: high performance densified small particle concrete (HPDSPC), steel fibre reinforced concrete (SFRC), slurry infiltrated concrete (SIFCON), Slurry infiltrated mat concrete (SIMCON)

Procedia PDF Downloads 277