Search results for: Pauline Janssen
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33

Search results for: Pauline Janssen

3 Optimization of Perfusion Distribution in Custom Vascular Stent-Grafts Through Patient-Specific CFD Models

Authors: Scott M. Black, Craig Maclean, Pauline Hall Barrientos, Konstantinos Ritos, Asimina Kazakidi

Abstract:

Aortic aneurysms and dissections are leading causes of death in cardiovascular disease. Both inevitably lead to hemodynamic instability without surgical intervention in the form of vascular stent-graft deployment. An accurate description of the aortic geometry and blood flow in patient-specific cases is vital for treatment planning and long-term success of such grafts, as they must generate physiological branch perfusion and in-stent hemodynamics. The aim of this study was to create patient-specific computational fluid dynamics (CFD) models through a multi-modality, multi-dimensional approach with boundary condition optimization to predict branch flow rates and in-stent hemodynamics in custom stent-graft configurations. Three-dimensional (3D) thoracoabdominal aortae were reconstructed from four-dimensional flow-magnetic resonance imaging (4D Flow-MRI) and computed tomography (CT) medical images. The former employed a novel approach to generate and enhance vessel lumen contrast via through-plane velocity at discrete, user defined cardiac time steps post-hoc. To produce patient-specific boundary conditions (BCs), the aortic geometry was reduced to a one-dimensional (1D) model. Thereafter, a zero-dimensional (0D) 3-Element Windkessel model (3EWM) was coupled to each terminal branch to represent the distal vasculature. In this coupled 0D-1D model, the 3EWM parameters were optimized to yield branch flow waveforms which are representative of the 4D Flow-MRI-derived in-vivo data. Thereafter, a 0D-3D CFD model was created, utilizing the optimized 3EWM BCs and a 4D Flow-MRI-obtained inlet velocity profile. A sensitivity analysis on the effects of stent-graft configuration and BC parameters was then undertaken using multiple stent-graft configurations and a range of distal vasculature conditions. 4D Flow-MRI granted unparalleled visualization of blood flow throughout the cardiac cycle in both the pre- and postsurgical states. Segmentation and reconstruction of healthy and stented regions from retrospective 4D Flow-MRI images also generated 3D models with geometries which were successfully validated against their CT-derived counterparts. 0D-1D coupling efficiently captured branch flow and pressure waveforms, while 0D-3D models also enabled 3D flow visualization and quantification of clinically relevant hemodynamic parameters for in-stent thrombosis and graft limb occlusion. It was apparent that changes in 3EWM BC parameters had a pronounced effect on perfusion distribution and near-wall hemodynamics. Results show that the 3EWM parameters could be iteratively changed to simulate a range of graft limb diameters and distal vasculature conditions for a given stent-graft to determine the optimal configuration prior to surgery. To conclude, this study outlined a methodology to aid in the prediction post-surgical branch perfusion and in-stent hemodynamics in patient specific cases for the implementation of custom stent-grafts.

Keywords: 4D flow-MRI, computational fluid dynamics, vascular stent-grafts, windkessel

Procedia PDF Downloads 147
2 Fully Instrumented Small-Scale Fire Resistance Benches for Aeronautical Composites Assessment

Authors: Fabienne Samyn, Pauline Tranchard, Sophie Duquesne, Emilie Goncalves, Bruno Estebe, Serge Boubigot

Abstract:

Stringent fire safety regulations are enforced in the aeronautical industry due to the consequences that potential fire event on an aircraft might imply. This is so much true that the fire issue is considered right from the design of the aircraft structure. Due to the incorporation of an increasing amount of polymer matrix composites in replacement of more conventional materials like metals, the nature of the fire risks is changing. The choice of materials used is consequently of prime importance as well as the evaluation of its resistance to fire. The fire testing is mostly done using the so-called certification tests according to standards such as the ISO2685:1998(E). The latter describes a protocol to evaluate the fire resistance of structures located in fire zone (ability to withstand fire for 5min). The test consists in exposing an at least 300x300mm² sample to an 1100°C propane flame with a calibrated heat flux of 116kW/m². This type of test is time-consuming, expensive and gives access to limited information in terms of fire behavior of the materials (pass or fail test). Consequently, it can barely be used for material development purposes. In this context, the laboratory UMET in collaboration with industrial partners has developed a horizontal and a vertical small-scale instrumented fire benches for the characterization of the fire behavior of composites. The benches using smaller samples (no more than 150x150mm²) enables to cut downs costs and hence to increase sampling throughput. However, the main added value of our benches is the instrumentation used to collect useful information to understand the behavior of the materials. Indeed, measurements of the sample backside temperature are performed using IR camera in both configurations. In addition, for the vertical set up, a complete characterization of the degradation process, can be achieved via mass loss measurements and quantification of the gasses released during the tests. These benches have been used to characterize and study the fire behavior of aeronautical carbon/epoxy composites. The horizontal set up has been used in particular to study the performances and durability of protective intumescent coating on 2mm thick 2D laminates. The efficiency of this approach has been validated, and the optimized coating thickness has been determined as well as the performances after aging. Reductions of the performances after aging were attributed to the migration of some of the coating additives. The vertical set up has enabled to investigate the degradation process of composites under fire. An isotropic and a unidirectional 4mm thick laminates have been characterized using the bench and post-fire analyses. The mass loss measurements and the gas phase analyses of both composites do not present significant differences unlike the temperature profiles in the thickness of the samples. The differences have been attributed to differences of thermal conductivity as well as delamination that is much more pronounced for the isotropic composite (observed on the IR-images). This has been confirmed by X-ray microtomography. The developed benches have proven to be valuable tools to develop fire safe composites.

Keywords: aeronautical carbon/epoxy composite, durability, intumescent coating, small-scale ‘ISO 2685 like’ fire resistance test, X-ray microtomography

Procedia PDF Downloads 246
1 Spectroscopic Study of the Anti-Inflammatory Action of Propofol and Its Oxidant Derivatives: Inhibition of the Myeloperoxidase Activity and of the Superoxide Anions Production by Neutrophils

Authors: Pauline Nyssen, Ange Mouithys-Mickalad, Maryse Hoebeke

Abstract:

Inflammation is a complex physiological phenomenon involving chemical and enzymatic mechanisms. Polymorphonuclear neutrophil leukocytes (PMNs) play an important role by producing reactive oxygen species (ROS) and releasing myeloperoxidase (MPO), a pro-oxidant enzyme. Released both in the phagolysosome and the extracellular medium, MPO produces during its peroxidase and halogenation cycles oxidant species, including hypochlorous acid, involved in the destruction of pathogen agents, like bacteria or viruses. Inflammatory pathologies, like rheumatoid arthritis, atherosclerosis induce an excessive stimulation of the PMNs and, therefore, an uncontrolled release of ROS and MPO in the extracellular medium, causing severe damages to the surrounding tissues and biomolecules such as proteins, lipids, and DNA. The treatment of chronic inflammatory pathologies remains a challenge. For many years, MPO has been used as a target for the development of effective treatments. Numerous studies have been focused on the design of new drugs presenting more efficient MPO inhibitory properties. However, some designed inhibitors can be toxic. An alternative consists of assessing the potential inhibitory action of clinically-known molecules, having antioxidant activity. Propofol, 2,6-diisopropyl phenol, which is used as an intravenous anesthetic agent, meets these requirements. Besides its anesthetic action employed to induce a sedative state during surgery or in intensive care units, propofol and its injectable form Diprivan indeed present antioxidant properties and act as ROS and free radical scavengers. A study has also evidenced the ability of propofol to inhibit the formation of the neutrophil extracellular traps fibers, which are important to trap pathogen microorganisms during the inflammation process. The aim of this study was to investigate the potential inhibitory action mechanism of propofol and Diprivan on MPO activity. To go into the anti-inflammatory action of propofol in-depth, two of its oxidative derivatives, 2,6-diisopropyl-1,4-p-benzoquinone (PPFQ) and 3,5,3’,5’-tetra isopropyl-(4,4’)-diphenoquinone (PPFDQ), were studied regarding their inhibitory action. Specific immunological extraction followed by enzyme detection (SIEFED) and molecular modeling have evidenced the low anti-catalytic action of propofol. Stopped-flow absorption spectroscopy and direct MPO activity analysis have proved that propofol acts as a reversible MPO inhibitor by interacting as a reductive substrate in the peroxidase cycle and promoting the accumulation of redox compound II. Overall, Diprivan exhibited a weaker inhibitory action than the active molecule propofol. In contrast, PPFQ seemed to bind and obstruct the enzyme active site, preventing the trigger of the MPO oxidant cycles. PPFQ induced a better chlorination cycle inhibition at basic and neutral pH in comparison to propofol. PPFDQ did not show any MPO inhibition activity. The three interest molecules have also demonstrated their inhibition ability on an important step of the inflammation pathway, the PMNs superoxide anions production, thanks to EPR spectroscopy and chemiluminescence. In conclusion, propofol presents an interesting immunomodulatory activity by acting as a reductive substrate in the peroxidase cycle of MPO, slowing down its activity, whereas PPFQ acts more as an anti-catalytic substrate. Although PPFDQ has no impact on MPO, it can act on the inflammation process by inhibiting the superoxide anions production by PMNs.

Keywords: Diprivan, inhibitor, myeloperoxidase, propofol, spectroscopy

Procedia PDF Downloads 120