Search results for: P. Holborn
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2

Search results for: P. Holborn

2 Mapping the Early History of Common Law Education in England, 1292-1500

Authors: Malcolm Richardson, Gabriele Richardson

Abstract:

This paper illustrates how historical problems can be studied successfully using GIS even in cases in which data, in the modern sense, is fragmentary. The overall problem under investigation is how early (1300-1500) English schools of Common Law moved from apprenticeship training in random individual London inns run in part by clerks of the royal chancery to become what is widely called 'the Third University of England,' a recognized system of independent but connected legal inns. This paper focuses on the preparatory legal inns, called the Inns of Chancery, rather than the senior (and still existing) Inns of Court. The immediate problem studied in this paper is how the junior legal inns were organized, staffed, and located from 1292 to about 1500, and what maps tell us about the role of the chancery clerks as managers of legal inns. The authors first uncovered the names of all chancery clerks of the period, most of them unrecorded in histories, from archival sources in the National Archives, Kew. Then they matched the names with London property leases. Using ArcGIS, the legal inns and their owners were plotted on a series of maps covering the period 1292 to 1500. The results show a distinct pattern of ownership of the legal inns and suggest a narrative that would help explain why the Inns of Chancery became serious centers of learning during the fifteenth century. In brief, lower-ranking chancery clerks, always looking for sources of income, discovered by 1370 that legal inns could be a source of income. Since chancery clerks were intimately involved with writs and other legal forms, and since the chancery itself had a long-standing training system, these clerks opened their own legal inns to train fledgling lawyers, estate managers, and scriveners. The maps clearly show growth patterns of ownership by the chancery clerks for both legal inns and other London properties in the areas of Holborn and The Strand between 1450 and 1417. However, the maps also show that a royal ordinance of 1417 forbidding chancery clerks to live with lawyers, law students, and other non-chancery personnel had an immediate effect, and properties in that area of London leased by chancery clerks simply stop after 1417. The long-term importance of the patterns shown in the maps is that while the presence of chancery clerks in the legal inns likely created a more coherent education system, their removal forced the legal profession, suddenly without a hostelry managerial class, to professionalize the inns and legal education themselves. Given the number and social status of members of the legal inns, the effect on English education was to free legal education from the limits of chancery clerk education (the clerks were not practicing common lawyers) and to enable it to become broader in theory and practice, in fact, a kind of 'finishing school' for the governing (if not noble) class.

Keywords: GIS, law, London, education

Procedia PDF Downloads 155
1 Buoyant Gas Dispersion in a Small Fuel Cell Enclosure: A Comparison Study Using Plain and Pressed Louvre Vent Passive Ventilation Schemes

Authors: T. Ghatauray, J. Ingram, P. Holborn

Abstract:

The transition from a ‘carbon rich’ fossil fuel dependent to a ‘sustainable’ and ‘renewable’ hydrogen based society will see the deployment of hydrogen fuel cells (HFC) in transport applications and in the generation of heat and power for buildings, as part of a decentralised power network. Many deployments will be low power HFCs for domestic combined heat and power (CHP) and commercial ‘transportable’ HFCs for environmental situations, such as lighting and telephone towers. For broad commercialisation of small fuel cells to be achieved there needs to be significant confidence in their safety in both domestic and environmental applications. Low power HFCs are housed in protective steel enclosures. Standard enclosures have plain rectangular ventilation openings intended for thermal management of electronics and not the dispersion of a buoyant gas. Degradation of the HFC or supply pipework in use could lead to a low-level leak and a build-up of hydrogen gas in the enclosure. Hydrogen’s wide flammable range (4-75%) is a significant safety concern, with ineffective enclosure ventilation having the potential to cause flammable mixtures to develop with the risk of explosion. Mechanical ventilation is effective at managing enclosure hydrogen concentrations, but drains HFC power and is vulnerable to failure. This is undesirable in low power and remote installations and reliable passive ventilation systems are preferred. Passive ventilation depends upon buoyancy driven flow, with the size, shape and position of ventilation openings critical for producing predictable flows and maintaining low buoyant gas concentrations. With environmentally sited enclosures, ventilation openings with pressed horizontal and angled louvres are preferred to protect the HFC and electronics inside. There is an economic cost to adding louvres, but also a safety concern. A question arises over whether the use of pressed louvre vents impairs enclosure passive ventilation performance, when compared to same opening area plain vents. Comparison small enclosure (0.144m³) tests of same opening area pressed louvre and plain vents were undertaken. A displacement ventilation arrangement was incorporated into the enclosure with opposing upper and lower ventilation openings. A range of vent areas were tested. Helium (used as a safe analogue for hydrogen) was released from a 4mm nozzle at the base of the enclosure to simulate a hydrogen leak at leak rates from 1 to 10 lpm. Helium sensors were used to record concentrations at eight heights in the enclosure. The enclosure was otherwise empty. These tests determined that the use of pressed and angled louvre ventilation openings on the enclosure impaired the passive ventilation flow and increased helium concentrations in the enclosure. High-level stratified buoyant gas layers were also found to be deeper than with plain vent openings and were within the flammable range. The presence of gas within the flammable range is of concern, particularly as the addition of the fuel cell and electronics in the enclosure would further reduce the available volume and increase concentrations. The opening area of louvre vents would need to be greater than equivalent plain vents to achieve comparable ventilation flows or alternative schemes would need to be considered.

Keywords: enclosure, fuel cell, helium, hydrogen safety, louvre vent, passive ventilation

Procedia PDF Downloads 256