Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2
Search results for: Nishal Mahatho
2 Design of a Hand-Held, Clamp-on, Leakage Current Sensor for High Voltage Direct Current Insulators
Authors: Morné Roman, Robert van Zyl, Nishanth Parus, Nishal Mahatho
Abstract:
Leakage current monitoring for high voltage transmission line insulators is of interest as a performance indicator. Presently, to the best of our knowledge, there is no commercially available, clamp-on type, non-intrusive device for measuring leakage current on energised high voltage direct current (HVDC) transmission line insulators. The South African power utility, Eskom, is investigating the development of such a hand-held sensor for two important applications; first, for continuous real-time condition monitoring of HVDC line insulators and, second, for use by live line workers to determine if it is safe to work on energised insulators. In this paper, a DC leakage current sensor based on magnetic field sensing techniques is developed. The magnetic field sensor used in the prototype can also detect alternating current up to 5 MHz. The DC leakage current prototype detects the magnetic field associated with the current flowing on the surface of the insulator. Preliminary HVDC leakage current measurements are performed on glass insulators. The results show that the prototype can accurately measure leakage current in the specified current range of 1-200 mA. The influence of external fields from the HVDC line itself on the leakage current measurements is mitigated through a differential magnetometer sensing technique. Thus, the developed sensor can perform measurements on in-service HVDC insulators. The research contributes to the body of knowledge by providing a sensor to measure leakage current on energised HVDC insulators non-intrusively. This sensor can also be used by live line workers to inform them whether or not it is safe to perform maintenance on energized insulators.Keywords: direct current, insulator, leakage current, live line, magnetic field, sensor, transmission lines
Procedia PDF Downloads 1711 Sequence Analysis and Structural Implications of Rotavirus Capsid Proteins
Authors: Nishal Parbhoo, John B. Dewar, Samantha Gildenhuys
Abstract:
Rotavirus is the major cause of severe gastroenteritis worldwide in children aged 5 and younger. Death rates are high particularly in developing countries. The mature rotavirus is a non-enveloped triple-layered nucleocapsid containing 11 double-stranded RNA segments. Here a global view on the sequence and structure of the three main capsid proteins, VP7, VP6, and VP2 is taken by generating a consensus sequence for each of these rotavirus proteins, for each species obtained from published data of representative rotavirus genotypes from across the world and across species. The degree of conservation between species was represented on homology models for each of the proteins. VP7 shows the highest level of variation with 14 - 45 amino acids showing conservation of less than 60%. These changes are localized to the outer surface which is exposed to antibodies alluding to a possible mechanism in evading the immune system. The middle layer, VP6 shows lower variability with only 14-32 sites having lower than 70% conservation. The inner structural layer made up of VP2 showed the lowest variability with only 1-16 sites having less than 70% conservation across species. The results correlate with proteins’ multiple structural roles. Although the nucleotide sequences vary due to an error-prone replication and lack of proofreading, the corresponding amino acid sequence of VP2, 6 and 7 remains conserved. Sequence conservation maintained for the virus results in stable protein structures, fit for function. This can be exploited in drug design, molecular studies and biotechnological applications.Keywords: amino acid sequence conservation, capsid protein, protein structure, vaccine candidate
Procedia PDF Downloads 290