Search results for: Alex Vanderstraten
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 123

Search results for: Alex Vanderstraten

3 Design of Experiment for Optimizing Immunoassay Microarray Printing

Authors: Alex J. Summers, Jasmine P. Devadhasan, Douglas Montgomery, Brittany Fischer, Jian Gu, Frederic Zenhausern

Abstract:

Immunoassays have been utilized for several applications, including the detection of pathogens. Our laboratory is in the development of a tier 1 biothreat panel utilizing Vertical Flow Assay (VFA) technology for simultaneous detection of pathogens and toxins. One method of manufacturing VFA membranes is with non-contact piezoelectric dispensing, which provides advantages, such as low-volume and rapid dispensing without compromising the structural integrity of antibody or substrate. Challenges of this processinclude premature discontinuation of dispensing and misaligned spotting. Preliminary data revealed the Yp 11C7 mAb (11C7)reagent to exhibit a large angle of failure during printing which may have contributed to variable printing outputs. A Design of Experiment (DOE) was executed using this reagent to investigate the effects of hydrostatic pressure and reagent concentration on microarray printing outputs. A Nano-plotter 2.1 (GeSIM, Germany) was used for printing antibody reagents ontonitrocellulose membrane sheets in a clean room environment. A spotting plan was executed using Spot-Front-End software to dispense volumes of 11C7 reagent (20-50 droplets; 1.5-5 mg/mL) in a 6-test spot array at 50 target membrane locations. Hydrostatic pressure was controlled by raising the Pressure Compensation Vessel (PCV) above or lowering it below our current working level. It was hypothesized that raising or lowering the PCV 6 inches would be sufficient to cause either liquid accumulation at the tip or discontinue droplet formation. After aspirating 11C7 reagent, we tested this hypothesis under stroboscope.75% of the effective raised PCV height and of our hypothesized lowered PCV height were used. Humidity (55%) was maintained using an Airwin BO-CT1 humidifier. The number and quality of membranes was assessed after staining printed membranes with dye. The droplet angle of failure was recorded before and after printing to determine a “stroboscope score” for each run. The DOE set was analyzed using JMP software. Hydrostatic pressure and reagent concentration had a significant effect on the number of membranes output. As hydrostatic pressure was increased by raising the PCV 3.75 inches or decreased by lowering the PCV -4.5 inches, membrane output decreased. However, with the hydrostatic pressure closest to equilibrium, our current working level, membrane output, reached the 50-membrane target. As the reagent concentration increased from 1.5 to 5 mg/mL, the membrane output also increased. Reagent concentration likely effected the number of membrane output due to the associated dispensing volume needed to saturate the membranes. However, only hydrostatic pressure had a significant effect on stroboscope score, which could be due to discontinuation of dispensing, and thus the stroboscope check could not find a droplet to record. Our JMP predictive model had a high degree of agreement with our observed results. The JMP model predicted that dispensing the highest concentration of 11C7 at our current PCV working level would yield the highest number of quality membranes, which correlated with our results. Acknowledgements: This work was supported by the Chemical Biological Technologies Directorate (Contract # HDTRA1-16-C-0026) and the Advanced Technology International (Contract # MCDC-18-04-09-002) from the Department of Defense Chemical and Biological Defense program through the Defense Threat Reduction Agency (DTRA).

Keywords: immunoassay, microarray, design of experiment, piezoelectric dispensing

Procedia PDF Downloads 182
2 'Sextually' Active: Teens, 'Sexting' and Gendered Double Standards in the Digital Age

Authors: Annalise Weckesser, Alex Wade, Clara Joergensen, Jerome Turner

Abstract:

Introduction: Digital mobile technologies afford Generation M a number of opportunities in terms of communication, creativity and connectivity in their social interactions. Yet these young people’s use of such technologies is often the source of moral panic with accordant social anxiety especially prevalent in media representations of teen ‘sexting,’ or the sending of sexually explicit images via smartphones. Thus far, most responses to youth sexting have largely been ineffective or unjust with adult authorities sometimes blaming victims of non-consensual sexting, using child pornography laws to paradoxically criminalise those they are designed to protect, and/or advising teenagers to simply abstain from the practice. Prevention strategies are further skewed, with sex education initiatives often targeted at girls, implying that they shoulder the responsibility of minimising the risks associated with sexting (e.g. revenge porn and sexual predation). Purpose of Study: Despite increasing public interest and concern about ‘teen sexting,’ there remains a dearth of research with young people regarding their experiences of navigating sex and relationships in the current digital media landscape. Furthermore, young people's views on sexting are rarely solicited in the policy and educational strategies aimed at them. To address this research-policy-education gap, an interdisciplinary team of four researchers (from anthropology, media, sociology and education) have undertaken a peer-to-peer research project to co-create a sexual health intervention. Methods: In the winter of 2015-2016, the research team conducted serial group interviews with four cohorts of students (aged 13 to 15) from a secondary school in the West Midlands, UK. To facilitate open dialogue, girls and boys were interviewed separately, and each group consisted of no more than four pupils. The team employed a range of participatory techniques to elicit young people’s views on sexting, its consequences, and its interventions. A final focus group session was conducted with all 14 male and female participants to explore developing a peer-to-peer ‘safe sexting’ education intervention. Findings: This presentation will highlight the ongoing, ‘old school’ sexual double standards at work within this new digital frontier. In the sharing of ‘nudes’ (teens’ preferred term to ‘sexting’) via social media apps (e.g. Snapchat and WhatsApp), girls felt sharing images was inherently risky and feared being blamed and ‘slut-shamed.’ In contrast, boys were seen to gain in social status if they accumulated nudes of female peers. Further, if boys had nudes of themselves shared without consent, they felt they were expected to simply ‘tough it out.’ The presentation will also explore what forms of supports teens desire to help them in their day-to-day navigation of these digitally mediated, heteronormative performances of teen femininity and masculinity expected of them. Conclusion: This is the first research project, within UK, conducted with rather than about teens and the phenomenon of sexting. It marks a timely and important contribution to the nascent, but growing body of knowledge on gender, sexual politics and the digital mobility of sexual images created by and circulated amongst young people.

Keywords: teens, sexting, gender, sexual politics

Procedia PDF Downloads 237
1 Development of Anti-Fouling Surface Features Bioinspired by the Patterned Micro-Textures of the Scophthalmus rhombus (Brill)

Authors: Ivan Maguire, Alan Barrett, Alex Forte, Sandra Kwiatkowska, Rohit Mishra, Jens Ducrèe, Fiona Regan

Abstract:

Biofouling is defined as the gradual accumulation of Biomimetics refers to the use and imitation of principles copied from nature. Biomimetics has found interest across many commercial disciplines. Among many biological objects and their functions, aquatic animals deserve a special attention due to their antimicrobial capabilities resulting from chemical composition, surface topography or other behavioural defences, which can be used as an inspiration for antifouling technology. Marine biofouling has detrimental effects on seagoing vessels, both commercial and leisure, as well as on oceanographic sensors, offshore drilling rigs, and aquaculture installations. Sensor optics, membranes, housings and platforms can become fouled leading to problems with sensor performance and data integrity. While many anti-fouling solutions are currently being investigated as a cost-cutting measure, biofouling settlement may also be prevented by creating a surface that does not satisfy the settlement conditions. Brill (Scophthalmus rhombus) is a small flatfish occurring in marine waters of Mediterranean as well as Norway and Iceland. It inhabits sandy and muddy coastal waters from 5 to 80 meters. Its skin colour changes depending on environment, but generally is brownish with light and dark freckles, with creamy underside. Brill is oval in shape and its flesh is white. The aim of this study is to translate the unique micro-topography of the brill scale, to design marine inspired biomimetic surface coating and test it against a typical fouling organism. Following extensive study of scale topography of the brill fish (Scophthalmus rhombus) and the settlement behaviour of the diatom species Psammodictyon sp. via SEM, two state-of-the-art antifouling surface solutions were designed and investigated; A brill fish scale bioinspired surface pattern platform (BFD), and generic and uniformly-arrayed, circular micropillar platform (MPD), with offsets based on diatom species settlement behaviour. The BFD approach consists of different ~5 μm by ~90 μm Brill-replica patterns, grown to a 5 μm height, in a linear array pattern. The MPD approach utilises hexagonal-packed cylindrical pillars 10.6 μm in diameter, grown to a height of 5 μm, with vertical offset of 15 μm and horizontal offset of 26.6 μm. Photolithography was employed for microstructure growth, with a polydimethylsiloxane (PDMS) chip-based used as a testbed for diatom adhesion on both platforms. Settlement and adhesion tests were performed using this PDMS microfluidic chip through subjugation to centrifugal force via an in-house developed ‘spin-stand’ which features a motor, in combination with a high-resolution camera, for real-time observing diatom release from PDMS material. Diatom adhesion strength can therefore be determined based on the centrifugal force generated at varying rotational speeds. It is hoped that both the replica and bio-inspired solutions will give comparable anti-fouling results to these synthetic surfaces, whilst also assisting in determining whether anti-fouling solutions should predominantly be investigating either fully bioreplica-based, or a bioinspired, synthetically-based design.

Keywords: anti-fouling applications, bio-inspired microstructures, centrifugal microfluidics, surface modification

Procedia PDF Downloads 317