Optimal Simultaneous Sizing and Siting of DGs and Smart Meters Considering Voltage Profile Improvement in Active Distribution Networks
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33104
Optimal Simultaneous Sizing and Siting of DGs and Smart Meters Considering Voltage Profile Improvement in Active Distribution Networks

Authors: T. Sattarpour, D. Nazarpour

Abstract:

This paper investigates the effect of simultaneous placement of DGs and smart meters (SMs), on voltage profile improvement in active distribution networks (ADNs). A substantial center of attention has recently been on responsive loads initiated in power system problem studies such as distributed generations (DGs). Existence of responsive loads in active distribution networks (ADNs) would have undeniable effect on sizing and siting of DGs. For this reason, an optimal framework is proposed for sizing and siting of DGs and SMs in ADNs. SMs are taken into consideration for the sake of successful implementing of demand response programs (DRPs) such as direct load control (DLC) with end-side consumers. Looking for voltage profile improvement, the optimization procedure is solved by genetic algorithm (GA) and tested on IEEE 33-bus distribution test system. Different scenarios with variations in the number of DG units, individual or simultaneous placing of DGs and SMs, and adaptive power factor (APF) mode for DGs to support reactive power have been established. The obtained results confirm the significant effect of DRPs and APF mode in determining the optimal size and site of DGs to be connected in ADN resulting to the improvement of voltage profile as well.

Keywords: Active distribution network (ADN), distributed generations (DGs), smart meters (SMs), demand response programs (DRPs), adaptive power factor (APF).

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1093972

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1770

References:


[1] M.M. Aman, G.B. Jasmon, A.H.A. Bakar, H. Mokhlis, "A new approach for optimum DG placement and sizing based on voltage stability maximization and minimization of power losses,” Energy Conversion and Management, vol. 70, pp. 202–210, 2013.
[2] R.P. Payasi, A. K.Singh, D. Singh, "Review of distributed generation planning: objectives, constraints, and algorithms,” International Journal of Engineering, Science and Technology, vol. 3, no. 3, pp. 133-153, 2011.
[3] W. El-Khattam, M.M.A. Salama, "Distributed generation technologies, definitions and benefits,” Electric Power Systems Research, vol. 71, pp. 119–128, 2004.
[4] S. Gopiya Naik, D.K. Khatod, M.P. Sharma, "Optimal allocation of combined DG and capacitor for real power loss minimization in distribution networks,” Electr Power Energy Syst, vol. 53, pp. 967–973, 2013.
[5] D.Q. Hung, N. Mithulananthan, R. C. Bansal, "Analytical expressions for DG allocation in primary distribution networks,” IEEE Tran Energy Conversion, vol. 25, no. 3, September 2010.
[6] Z. Hu, F. Li, "Cost-Benefit analyses of active distribution network management, part I: annual benefit analysis,” IEEE Tran Smart Grid, vol. 3, no. 3, September 2012.
[7] P. MacDougall, P. Heskes, P. Crolla, "Fast demand response in support of the active distribution network,” in Proc. 22nd International Conference on Electricity Distribution, Paper1024, Stockholm, 10-13 June 2013.
[8] B. Chakrabarti, D. Bullen, C. Edwards, C. Callaghan, "Demand response in the New Zealand electricity market,” in Proc. Transmission and Distribution Conference and Exposition (T&D), IEEE PES, pp. 1–7, 2012.
[9] P. Palensky, D. Dietrich, "Demand side management: demand response, intelligent energy systems, and smart loads,” IEEE Tran Industrial Informatics, vol. 7, no. 3, August 2011.
[10] S. Kansal, B.B.R. Sai, B. Tyagi, V. Kumar, "Optimal placement of distributed generation in distribution networks,” International Journal Engineering, Science & Technology, vol. 3, no. 3, pp. 47-55, 2011.
[11] M.H. Hemmatpour, M. Mohammadian, M. Rezaie Estabragh, "A novel approach for the reconfiguration of distribution systems considering the voltage stability margin,” Turk J Elec Eng & Comp Sci, vol. 21, pp. 679-698, 2013.
[12] M.M. Aman, G.B. Jasmon, H. Mokhlis, A.H.A. Bakar, "Optimal placement and sizing of a DG based on a new power stability index and line losses,” Electr Power Energy Syst, vol. 43, pp. 1296–1304, 2012.
[13] S. Ghosh, S.P. Ghoshal, S. Ghosh, "Development of smart distribution grid,” in Proc. Electr Power Energy Syst, vol. 32, pp. 849–856, 2010.
[14] S. Golshannavaz, "Optimal simultaneous siting and sizing of DGs and capacitors considering reconfiguration in smart automated distribution systems,” J Intelligent Fuzzy Syst, vol. 10, 2014.
[15] H. E.A, Talaat, E. Al-Ammar, "Optimal allocation and sizing of distributed generation in distribution networks using genetic algorithms,” in Proc. 11th International Conference on Electrical Power Quality and Utilisation (EPQU), pp. 1–6, 2011.
[16] S. Chandramohan, N. Atturulu, R.P. Kumudini Devi, B. Venkatesh, "Operating cost minimization of a radial distribution system in a deregulated electricity market through reconfiguration using NSGA method,” Electr Power Energy Syst, vol. 32, pp. 126–132, 2010.
[17] N. Rugthaicharoencheep, S. Sirisumrannukul, "Feeder reconfiguration for loss reduction in distribution system with distributed generators by Tabu search,” GMSARN International Journal, vol. 3, pp. 47–54, 2009.