Experimental Investigation on Cold-formed Steel Wall Plate System
Authors: A. L. Y. Ng, W. H. Hii
Abstract:
A series of tests on cold-formed steel (CFS) wall plate system subjected to uplift force at the mid span of the wall plate is presented. The aim of the study was to study the behaviour and identify the modes of failure of CFS wall plate system. Two parameters were considered in these studies: 1) different dimension of U-bracket at the supports and 2) different sizes of lipped C-channel. The lipped C-channels used were C07508, C07512 and C10012. The dimensions of the leg of U-bracket were 50x35 mm and 50x60 mm respectively, where 25 mm clearance was provided to the connections for specimens with clearance. Results show that specimens with and without clearance experienced the same mode of failure. Failure began with the yielding of the connectors followed by distortional buckling of the wall plate. However, when C075 sections were used as wall plate, the system behaved differently. There was a large deformation in the wall plate and failure began in the distortional buckling of the wall plate followed by bearing of the connecting plates at the supports (U-bracket). The ultimate strength of the system also decreased dramatically when C075 sections were used.
Keywords: Cold-formed steel, wall plate system, distortional buckling, full scale laboratory test.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1093464
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2196References:
[1] Kementerian Kewangan Malaysia, Pelaksanaan Industrialised Building System (IBS) dalam projek kerajaan, (S/K.KEW/PK/PP/1100/ 000000/10/31 JId. 25 SK3 (11)), Kementerian Kewangan Malaysia, Malaysia, 2008.
[2] H. Wang and Y. Zhang, "Experimental and numerical investigation on cold-formed steel C-section flexural members,” Journal of Constructional Steel Research, vol. 65, pp. 1225–1235, 2009.
[3] G. J. Hancock, Cold-formed steel structures: design of cold-formed steel structures (to AS/NZS 4600:2005), 4th edn, Australian Steel Institute, Australia, 2007.
[4] A. L. Y. Ng and C. C. Mei, "The behavior of cold-formed steel anchor plate subjected to pure axial tension force,” 4th International Conference on Steel & Composite Structures, Sydney, Australia, July 21-23, 2010.
[5] Jabatan Kerja Raya Malaysia, Makluman spesifikasi terkini JKR: Pre-fabricated cold formed steel roof trusses, (JKR 20601-0186-11), Jabatan Kerja Raya Malaysia, Kuala Lumpur, Malaysia, 2012.
[6] Australian Standard, Metallic materials: tensile testing at ambient temperature, (AS 1391: 2007), Standards Australia, 2007.