Ammonia Release during Photocopying Operations
Authors: Kiurski S. Jelena, Kecić S. Vesna, Oros B. Ivana, Ranogajec G. Jonjaua
Abstract:
The paper represents the dependence of ammonia concentration on microclimate parameters and photocopying shop circulation. The concentration of ammonia was determined during 8-hours working time over five days including three sampling points of a photocopying shop in Novi Sad, Serbia. The obtained results pointed out that the room temperature possesses the highest impact on ammonia release. The obtained ammonia concentration was in the range of 1.53 to 0.42ppm and decreased with the temperature decreasing from 24.6 to 20.7oC. As the detected concentrations were within the permissible levels of The Occupational Safety and Health Administration, The National Institute for Occupational Safety and The Health and Official Gazette of Republic of Serbia, in the range of 35 to 200ppm, there was no danger to the employee’s health in the photocopying shop.
Keywords: Ammonia, emission, indoor environment, photocopying procedure.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1091896
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2244References:
[1] C.-W. Lee, and D.-J. Hsu, "Measurements of fine and ultrafine particles formation in photocopy centers in Taiwan”, Atmos. Environ., vol. 41, pp. 6598-6609, Apr. 2007.
[2] D. D. Massey, and A. Taneja, "Emission and Formation of Fine Particles from Hardcopy Devices: the Cause of Indoor Air Pollution”, in Monitoring, Control and Effects of Air Pollution, A. G. Chmielewski, Ed., Croatia: InTech, 2011, pp.121-134.
[3] The Health and Safety Department, "Photocopiers and Laser Printers Health Hazards”, The University of Edinburgh, Edinburgh, pp. 1-6, Apr. 2010.
[4] A. D. Bermel, L. P. DeMejo, and J. C. Wilson, "Ester-containing quaternary ammonium salts as adhesion improving toner charge agents”, United State Patent, US 5194472 A, Mar. 1993.
[5] U. Ewers, and D. Nowak, "Health hazards caused by emissions of laser printers and copiers?”, Gefahrst Reinhalt Luft, vol. 5, pp. 203-210, May 2006.
[6] H. Destaillats, R. L. Maddalena, B. C. Singer, A. T. Hodgson, and T. E. McKone, "Indoor pollutants emitted by office equipment: A review of reported data and information needs”, Atmos. Environ., vol. 42, no. 7, pp. 1371-1388, Mar. 2008.
[7] C. He, L. Morawska, and L. Taplin, "Particle Emission Characteristics of Office Printers”, Environ. Sci. Technol., vol. 41, no. 17, pp 6039-6045, Aug. 2007.
[8] C. S. Lee, S. Lam, and K. H. Fai, "Characterization of VOCs, ozone, and PM10 emissions from office equipment in an environmental chamber”, Build. Environ., vol. 369, no. 7, pp. 837-842, June 2001.
[9] V. Kecić, S. Aksentijević, I. Oros, J. Kiurski, "Indoor emission of prepress procesess”, in Proc. 15th Danube-Kris-Mures-Tisa (DKMT) Euroregion Conf. on Environment and Health, Novi Sad, Serbia, 2013, pp. 181-186.
[10] G. Roller, "Quantitative risk assessment for the exposure to toner emissions from copiers”, Gefahrstoffe - Reinhaltung der Luft Air Quality Control, vol. 5, pp. 211-216, May 2006.
[11] M. Wensing, T. Schripp, E. Uhde, and T. Salthammer, "Ultra-fine particles release from hardcopy devices: Sources, real-room measurements and efficiency of filter accessories”, Sci. Total Environ., vol. 407, pp. 418-427, Sept. 2008.
[12] Occupational Safety and Health Standards (OSHA), "Limits for Air Contaminants Toxic and Hazardous Substances”, 1910.1000 TABLE Z-1, www.osha.gov, 2006.
[13] National Institute for Occupational Safety and Health (NIOSH), "IDLH Documentation”, www.cdc.gov, 1996.
[14] Official Gazette of Republic of Serbia, "Regulation about the permissible limits, methods of emission measuring, criteria for establishing of measuring points and data recording”, No. 54/92, 30/99 and 19/2006, Serbia, 2006.