Abstract:
The differential column shortening in tall buildings can be reduced by improving material and structural characteristics of the structural systems. This paper proposes structural methods to reduce differential column shortening in reinforced concrete tall buildings; connecting columns with rigidly jointed horizontal members, using outriggers, and placing additional reinforcement at the columns. The rigidly connected horizontal members including outriggers reduce the differential shortening between adjacent vertical members. The axial stiffness of columns with greater shortening can be effectively increased by placing additional reinforcement at the columns, thus the differential column shortening can be reduced in the design stage. The optimum distribution of additional reinforcement can be determined by applying a gradient based optimization technique.
Keywords: Column shortening, long-term behavior, optimization, tall building.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1090705
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4009References:
[1] M. Fintel, S. K. Ghosh, and H. Iyengar, Column shortening in tall structure-prediction and compensation, Portand Cement Association, Skokie, IL, 1987.
[2] H. S. Kim, "Effect of horizontal members on column shortening of reinforced concrete building structures,” Struct. Design Tall Spec. Build., vol. 22, pp.440-453, 2013
[3] R. I. Gilbert, Time effects in concrete structures, Elsevier, Amsterdam, 1988.
[4] Z. P. Bazant and F. H. Wittmann, Creep and shrinkage in concrete structures, John Wiley & Sons, New York, 1982.
[5] CEB (Comite Euro-International Du Beton), CEB-FIP model code 1990, Thomas Telford Services Ltd, London, 1993.
[6] A. R. Parkinson, R. Balling, and J. D. Hedengren, Optimization Methods for Engineering Design, Brigham Young University, 2013.