Abstract:
In this research, the TRACE/PARCS model of Lungmen ABWR has been developed for verification of ultimate response guideline (URG) efficiency. This ultimate measure was named as DIVing plan, abbreviated from system depressurization, water injection and containment venting. The simulation initial condition is 100% rated power/100% rated core flow. This research focuses on the estimation of the time when the fuel might be damaged with no water injection by using TRACE/PARCS first. Then, the effect of the reactor core isolation system (RCIC), control depressurization and ac-independent water addition system (ACIWA), which can provide the injection with 950 gpm are also estimated for the station blackout (SBO) transient.
Keywords: ABWR, TRACE, safety analysis, PARCS.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1336160
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2225References:
[1] K.S. Liang, S.C. Chiang, Y.F. Hsu, H.J. Young, B.S. Pei, L.C. Wang, "The ultimate emergency measures to secure a NPP under an accidental condition with no designed power or water supply,” Nuclear Engineering and Design, 253, pp.259-268,2012.
[2] Taiwan Power Company, "Final Safety Analysis Report for Lungmen Nuclear Power Station Units 1&2 (FSAR),”2007.
[3] L.S. Kao, J.R. Wang, R.Y. Yuann, W.H. Tung, J.A. Jing, C.T. Lin, "Parallel calculations and verifications of limiting transient analyses for Lungmen nuclear power plant.,” INER report, INER-A1609R,2008.
[4] L.S. Kao, J.R. Wang, J.R. Tang, J.A. Jing, W. H. Tung, R. Y. Yuann, C. T. Lin, H.T. Lin, " Development of Lungmen ABWR Thermal hydraulic Safety analysis Method-The Summary Report,” INER report, INER-A1742R, 2008.
[5] H. T. Lin, J. R. Wang, C. Shih, "The development and assessment of TRACE model for Lungmen ABWR”, KERNTECHNIK, Vol. 76, pp. 205-215, 2011.
[6] H. T. Lin, J. R. Wang, C. Shih, "The development of Lungmen ABWR TRACE safety analysis model,”2011 International Conference on Frontiers of Manufacturing and Design Science (ICFMD), Taiwan, 2011.
[7] J.R. Wang, H. T. Lin, H. C. Chen, W. C. Wang, C. Shih, "Station Black Out Analysis of Lungmen ABWR Using TRACE,” Proceedings of the 20th International Conference on Nuclear Engineering, Anaheim, July 30 - August 3, 2011.