Abstract:

In this research, the TRACE/PARCS model of  Lungmen ABWR has been developed for verification of ultimate  response guideline (URG) efficiency. This ultimate measure was  named as DIVing plan, abbreviated from system depressurization,  water injection and containment venting. The simulation initial  condition is 100% rated power/100% rated core flow. This research  focuses on the estimation of the time when the fuel might be damaged  with no water injection by using TRACE/PARCS first. Then, the  effect of the reactor core isolation system (RCIC), control  depressurization and ac-independent water addition system (ACIWA),  which can provide the injection with 950 gpm are also estimated for  the station blackout (SBO) transient.

 

Keywords: ABWR, TRACE, safety analysis, PARCS.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1336160

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2225

References:


[1] K.S. Liang, S.C. Chiang, Y.F. Hsu, H.J. Young, B.S. Pei, L.C. Wang, "The ultimate emergency measures to secure a NPP under an accidental condition with no designed power or water supply,” Nuclear Engineering and Design, 253, pp.259-268,2012.
[2] Taiwan Power Company, "Final Safety Analysis Report for Lungmen Nuclear Power Station Units 1&2 (FSAR),”2007.
[3] L.S. Kao, J.R. Wang, R.Y. Yuann, W.H. Tung, J.A. Jing, C.T. Lin, "Parallel calculations and verifications of limiting transient analyses for Lungmen nuclear power plant.,” INER report, INER-A1609R,2008.
[4] L.S. Kao, J.R. Wang, J.R. Tang, J.A. Jing, W. H. Tung, R. Y. Yuann, C. T. Lin, H.T. Lin, " Development of Lungmen ABWR Thermal hydraulic Safety analysis Method-The Summary Report,” INER report, INER-A1742R, 2008.
[5] H. T. Lin, J. R. Wang, C. Shih, "The development and assessment of TRACE model for Lungmen ABWR”, KERNTECHNIK, Vol. 76, pp. 205-215, 2011.
[6] H. T. Lin, J. R. Wang, C. Shih, "The development of Lungmen ABWR TRACE safety analysis model,”2011 International Conference on Frontiers of Manufacturing and Design Science (ICFMD), Taiwan, 2011.
[7] J.R. Wang, H. T. Lin, H. C. Chen, W. C. Wang, C. Shih, "Station Black Out Analysis of Lungmen ABWR Using TRACE,” Proceedings of the 20th International Conference on Nuclear Engineering, Anaheim, July 30 - August 3, 2011.