Dynamic Analysis of the Dome with Arches and Rings from Romexpo Bucharest
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32797
Dynamic Analysis of the Dome with Arches and Rings from Romexpo Bucharest

Authors: V. Precupas, A. Ivan, M. Ivan

Abstract:

The dome with ribs and rings, which covers the ROMEXPO pavilion from Bucharest, was designed after the collapse of the single layer reticulated dome. In this paper, it was made the checking of the structure, under the dynamic loads with three recorded accelerograms calibrated according to Romanian seismic design code P100-1/2006. Under the action the dynamic loadings, it was made a time-history analysis to determine the zones where the plastic hinges appear, at what accelerations and their position on the structure. The studied dome is formed by 32 spatial semi arches and three rings: one circular ring located at the top of the dome and another two rings, design as trusses, the first near the supports and the second as an intermediate rings above the skylights. Above the skylights up to the top, the dome is tight together with purlins and bracings.

Keywords: dome, dynamic analysis, plastic hinges, time-history

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1059531

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2396

References:


[1] D. Mateescu and collaborators, Welded metallic dome of National Economy Exhibition Pavilion of R.P.R.
[2] A. Ivan, Single layer reticulated metallic dome instability, Romanian Academy Publishing, Bucharest, Ph. D Dissertation, 2001.
[3] Technical design ÔÇ×Remaking of the National Economy Pavilion roof" developed by collective of I.P.C.M.C. Bucharest, 1963
[4] Seismic design code - Part I - Design provisions for buildings, code P100-1/2006.
[5] Design code CR 0-2005, Bases of design for structures in construction.
[6] Design code NP-082-04. Bases of design and actions on constructions. Wind loading.
[7] Design code CR 1-1-3-05 Evaluation of snow loadings upon constructions.
[8] STAS 10108/0-78 Steel elements computation.
[9] Eurocode 8 - Design provisions for earthquake resistance of structures - Part 1-1;
[10] E. Baiculescu, M. Enescu, The design of the pavilion of National Economy Exhibition of R.P.R. in "Construction and construction materials magazine". 1962
[11] M. Soare, N. Pâtr├«niche, The metallic reticulated dome from National Economy Exhibition pavilion of R.P.R., in "Construction and construction materials magazine". 1962.
[12] T. Dinescu, M. Anastasescu, The mounting design of the dome from National Economy Exhibition pavilion of R.P.R., in "Construction and construction materials magazine". 1962.
[13] F. DINU, Methods of nonlinear computation of metallic frame structures loaded by seismic action, "Edituraorizonturiuniversitare" editure, Timișoara, 2006
[14] D. Dubinâ, D.Lungu (coordinators), authors collective Aldea A., Arion C., Ciutina A., Cornea T. Dinu F., Fulop L., Grecea D., Stratan A., Vâcâreanu R. Constructions placed in strong seismic movement zones, "Edituraorizonturiuniversitare" editure, Timi╚Öoara, 2003
[15] FEMA 356, Prestandard and commentary for the seismic rehabilitation of buildings, Federal Emergency Management Acency, Washington D.C., 2000