Mathematical Modelling of Venturi Scrubber for Ammonia Absorption
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33104
Mathematical Modelling of Venturi Scrubber for Ammonia Absorption

Authors: S.Mousavian, D.Ashouri, M.abdolahi, M.H.Vakili, Y.Rahnama

Abstract:

In this study, the dispersed model is used to predict gas phase concentration, liquid drop concentration. The venturi scrubber efficiency is calculated by gas phase concentration. The modified model has been validated with available experimental data of Johnstone, Field and Tasler for a range of throat gas velocities, liquid to gas ratios and particle diameters and is used to study the effect of some design parameters on collection efficiency.

Keywords: Ammonia, Modelling, Purge gas, Removal efficiency, Venturi scrubber

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1332132

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2473

References:


[1] H.F. Johnstone, R.B. Feild, M.C. Tassler, Ind. Eng. Chem. 46 (8) (1954) 1601.
[2] M.D. Kuznetsov, V.I. Oratovskii, Int. Chem. Eng. 2 (2) (1962) 85.
[3] Kh. Boyadzhiev, Int. Chem. Eng. 4 (1) (1964) 22.
[4] D. Elenkov, Kh. Boyadzhiev, Int. Chem. Eng. 7 (2) (1967) 191.
[5] B.P. Volgin, T.F. Efimova, M.S. Gofman, Int. Chem. Eng. 8 (1) (1968) 113.
[6] S. Uchida, C.Y. Wen, Ind. Eng. Chem. Process Des. Dev. 12 (4) (1973) 437.
[7] Fathikalajahi . J , Taheri . M , Talaie . M . R , (1996) , " Theoretical study of non uniform droplet concentration distribution on venturi scrubber performance " , Part . Sci . Tech , Vol . 14 , page 153