Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Implementation of the Personal Emergency Response System
Authors: Ah-young Jeon, In-cheol Kim, Jae-hee Jung, Soo-young Ye, Jae-hyung Kim, Ki-gon Nam, Seoung-wan Baik, Jung-hoon Ro, Gye-rok Jeon
Abstract:
The aged are faced with increasing risk for falls. The aged have the easily fragile bones than others. When falls have occurred, it is important to detect this emergency state because such events often lead to more serious illness or even death. A implementation of PDA system, for detection of emergency situation, was developed using 3-axis accelerometer in this paper as follows. The signals were acquired from the 3-axis accelerometer, and then transmitted to the PDA through Bluetooth module. This system can classify the human activity, and also detect the emergency state like falls. When the fall occurs, the system generates the alarm on the PDA. If a subject does not respond to the alarm, the system determines whether the current situation is an emergency state or not, and then sends some information to the emergency center in the case of urgent situation. Three different studies were conducted on 12 experimental subjects, with results indicating a good accuracy. The first study was performed to detect the posture change of human daily activity. The second study was performed to detect the correct direction of fall. The third study was conducted to check the classification of the daily physical activity. Each test was lasted at least 1 min. in third study. The output of acceleration signal was compared and evaluated by changing a various posture after attaching a 3-axis accelerometer module on the chest. The newly developed system has some important features such as portability, convenience and low cost. One of the main advantages of this system is that it is available at home healthcare environment. Another important feature lies in low cost to manufacture device. The implemented system can detect the fall accurately, so will be widely used in emergency situation.Keywords: Alarm System, Ambulatory monitoring, Emergency detection, Classification of activity, and 3-axis accelerometer.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1330949
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1599References:
[1] Rytömaa I, Meurman JH, Koskinen J, et al. " In vitro erosion of bovine enamel caused by acidic drinks and other foodstuffs," Scand J Dent Re, 96 , pp. 324-333, 1988.
[2] 9.Johansson AK, Lingström P, Imfeld T, et al. " Influence of drinking method on tooth-surface pH in relation to dental erosion," Eur J Oral Sci, 112, pp. 484-489, 2004.
[3] Fosdick LS, Campaigne EE, Fancher O ," Rate of acid formation in carious areas: the etiology of dental caries," Ill Dent J, vol. 10, pp. 85-95, 1941.
[4] 20.Frostell G ," A method for evaluation of acid potentialities of foods," Acta Odontol Scand, vol. 28, pp.599-608, 1970.
[5] Kleinberg I, Jenkins GN, Chatterjee R, et al. ,"The antimony pH electrode and its role in the assessment and interpretation of dental plaque pH," J Dent Res, vol. 61, pp. 1139-1147, 1982.
[6] Graf H, M├╝hlemann HR ,"Telemetry of plaque pH from interdental areas," Helv Odontol Acta, vol. 10. pp. 94-101, 1966.
[7] Anderson P, Hector MP, Rampersad MA,"Critical pH in resting and stimulated whole saliva in groups of children and adults," Int J Paediatr Dent vol. 11, pp. 266-73, 2001.
[8] Pandolfino JE, Ghosh S, Zhang Q, et al. ,"Slimline vs. glass pH electrodes: what degree of accuracy should we expect?," Aliment Pharmacol Ther, vol. 23, pp. 331-340, 2006.