Effect of U-Turn in Reinforced Concrete Dog-Legged Stair Slabs
Authors: Abdul Baqi, Zaid Mohammad
Abstract:
Reinforced concrete stair slabs with mid landings i.e. Dog-legged shaped are conventionally designed as per specifications of standard codes of practices which guide about the effective span according to the varying support conditions. Presently, the behavior of such slabs has been investigated using Finite Element method. A single flight stair slab with landings on both sides and supported at ends on wall, and a multi flight stair slab with landings and six different support arrangements have been analyzed. The results obtained for stresses, strains and deflections are used to describe the behavior of such stair slabs, including locations of critical moments and deflections. Values of critical moments obtained by F.E. analysis have also have been compared with that obtained from conventional analysis. Analytical results show that the moments are also critical near the kinks i.e. junction of mid-landing and inclined waist slab. This change in the behavior of dog-legged stair slab may be due to continuity of the material in transverse direction in two landings adjoining the waist slab, hence additional stiffness achieved. This change in the behavior is generally not taken care of in conventional method of design.Keywords: Dog-legged, Stair slab, F.E. Analysis, Landing, Reinforced concrete.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1058847
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4556References:
[1] Building Code Requirement for Structural Concrete (ACI-318-05), American Concrete Institute, 2005.
[2] British Standard: Structural Use of Concrete Part-I (Code of Practice for Design and Construction), BS 8110 Part 1: 1985, British Standards Institution, May, 1989.
[3] Indian Standard: Plain and Reinforced Concrete- Code of practice (IS- 456: 2000) Bureau of Indian Standards, New Delhi, July, 2000.
[4] I. Ahmed, A. Muqtadir and S. Ahmed, "A Design Basis for Stair Slabs Supported at Landing Level", Journal of Structural Engineering, ASCE, Vol. 121(7), July 1995, pp.1051-1057.
[5] I. Ahmed, A. Muqtadir and S. Ahmed, "Design Provisions for Stair Slabs in the Bangladesh Building Code", Journal of Structural Engineering, ASCE, Vol. 122(3), March 1996, pp.262-266.
[6] M. Aslam, "Analysis of Two Flight Staircase by Finite Element Method", M. Tech. (Civil Engg.) Dissertation, Department of Civil Engineering, Aligarh Muslim University, Aligarh, India, 2004.
[7] M. Y. Yahya, "An Analysis of the effect of Staircase Intermediate Landing Floor on the Evaluation Time", Journal Alam Bina, Jilid 12 : No.3, 2008.