Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33093
Coordinated Q–V Controller for Multi-machine Steam Power Plant: Design and Validation
Authors: Jasna Dragosavac, Žarko Janda, J.V. Milanović, Dušan Arnautović
Abstract:
This paper discusses coordinated reactive power - voltage (Q-V) control in a multi machine steam power plant. The drawbacks of manual Q-V control are briefly listed, and the design requirements for coordinated Q-V controller are specified. Theoretical background and mathematical model of the new controller are presented next followed by validation of developed Matlab/Simulink model through comparison with recorded responses in real steam power plant and description of practical realisation of the controller. Finally, the performance of commissioned controller is illustrated on several examples of coordinated Q-V control in real steam power plant and compared with manual control.Keywords: Coordinated Voltage Control, Power Plant Control, Reactive Power Control, Sensitivity Matrix
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1056078
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2186References:
[1] J. D. Hurley, L. N. Bize, C. R. Mummert, "The Adverse Effects of Excitation System Var and Power Factor Controllers, IEEE Transactions on Energy Conversion, Vol. 14, No. 4, pp:1636 - 1645 Dec. 1999.
[2] P. Lagonotte, J. C. Sabonnadiere, J. Y. Leost, , J. P. Paul, "Structural analysis of the electrical system : application to the secondary voltage control in France," IEEE Transactions on Power Systems, Vol. 2, pp. 479-484, 1989.
[3] S. Corsi, M. Pozzi, C. Sabelli, A. Serrani, " The Coordinated Automatic Voltage Control of the Italian Transmission Grid, Part II : Control apparatuses and field performance of the consolidated hierarchical system", IEEE Trans. on Power Systems, November 2004, Volume 19, Number 4, pp 1733-1741.
[4] W. Yu, H. Lee, D. Hur, C. Lim, T. Kim, J. Shin, S. Nam, Hybrid Intelligent Voltage and Reactive Power Control System for Jeju Power System in Korea, 8th WSEAS International Conference on Power Systems, Santander, Cantabria, Spain, September 23-25, 2008.
[5] J. Machowski, J. W. Bialek, J. R. Bumby, Power System Dynamics: Stability And Control, , John Wiley & Sons, Chichester, 2008, pp 113 - 115.
[6] John Grainger, Jr.,William Stevenson, Power System Analysis, McGraw-Hill, 1994, p 369.
[7] K. Iba, H. Suzuki, M. Egawa, and T. Watanabe, "Calculation of Critical Loading Condition with Nose Curve Using Homotopy Continuation Method," IEEE Transactions on Power Systems, vol. 6, 1991.
[8] Ajjarapu, Computational Techniques for Voltage Stability Assessment and Control, Iowa: Springer, 2006, pp 51 - 53.