Reliability Analysis of P-I Diagram Formula for RC Column Subjected to Blast Load
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32804
Reliability Analysis of P-I Diagram Formula for RC Column Subjected to Blast Load

Authors: Masoud Abedini, Azrul A. Mutalib, Shahrizan Baharom, Hong Hao

Abstract:

This study was conducted published to investigate there liability of the equation pressure-impulse (PI) reinforced concrete column inprevious studies. Equation involves three different levels of damage criteria known as D =0. 2, D =0. 5 and D =0. 8.The damage criteria known as a minor when 0-0.2, 0.2-0.5is known as moderate damage, high damage known as 0.5-0.8, and 0.8-1 of the structure is considered a failure. In this study, two types of reliability analyzes conducted. First, using pressure-impulse equation with different parameters. The parameters involved are the concrete strength, depth, width, and height column, the ratio of longitudinal reinforcement and transverse reinforcement ratio. In the first analysis of the reliability of this new equation is derived to improve the previous equations. The second reliability analysis involves three types of columns used to derive the PI curve diagram using the derived equation to compare with the equation derived from other researchers and graph minimum standoff versus weapon yield Federal Emergency Management Agency (FEMA). The results showed that the derived equation is more accurate with FEMA standards than previous researchers.

Keywords: Blast load, RC column, P-I curve, Analytical formulae, Standard FEMA.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1086733

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2863

References:


[1] Crawford J. E., Malvar L. J., Morrill K. B., Ferritto J. M, “Composite retrofits to increase the blast resistance of reinforced concrete buildings,“In: Proceedings of the 10th international symposium on interaction of the effects of munitions with structures. San Diego, USA. hlm. 1–13,2001.
[2] Crawford JE, Malvar LJ, Kenneth BM, “Reinforced concrete column retrofit methods for seismic and blast protection,”In: Proceeding of the SAME National Symposium on Comprehensive Force Protection, Charleston, SC, 2001.
[3] Crawford JE, Malvar LJ, Wesevich JW, Valancius J, Reynolds AD, “Retrofit of reinforced concrete structures to resist blast effects,”ACI Structural Journal;94(4):371e7,1997.
[4] FEMA-427, “Risk Management Series: Primer for Design of Commercial Building to Mitigate Terrorist Attacks,”Applied Technology Council (ATC) and Eve Hinman, Hinman Consulting Engineers,2003.
[5] FEMA-428, “Risk Management Series: Primer for Design of Commercial Building to Mitigate Terrorist Attacks,”Applied Technology Council (ATC) and Eve Hinman, Hinman Consulting Engineers, 2003.
[6] Shi Y, Hao H, Li ZX, “Numerical derivation of pressure-impulse diagrams for prediction of RC column damage to blast loads,”International Journal of Impact Engineering;35:1213e27, 2008.
[7] Malvar L.J., Crawford J.E., Wesevich J.W., Simons D, “A plasticity concrete material model for DYNA3D,” InternationalJournal of Impact Engineering 19: 847-873,1997.
[8] Muszynski LC, Purcel MR, Sierakowski R, “Strengthening concrete structures by using externally applied composite reinforcing material,” In: Proccedings of the seventh international symposium on interaction of the effects of munitions with structures, Germany,1995.
[9] Mutalib A. A. and Hao H, “Development of P-I diagram for FRP strengthened RC columns,”International Journal of Impact Engineering 10(38): 290-304,2011.
[10] Wood BH, “Experimental validation of an integrated FRP and viscoelastic hardening, damping and wave-modulation system for blast resistance enhancement of RC columns,”Rolla, Missouri, US: Missouri University of Science and Technology,2008.