An Optical Sensing Film for Fe(III) Determination Based on 1,1′- diethyl 2,2′- cyanine Iodide Immobilized in Nafion Film
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33093
An Optical Sensing Film for Fe(III) Determination Based on 1,1′- diethyl 2,2′- cyanine Iodide Immobilized in Nafion Film

Authors: K. Kajsanthia, J. Wittayakun, S. Prayoonpokarach

Abstract:

An optical chemical sensing film based on immobilizing of 1,1′- diethyl 2,2′-cyanine (pseudocyanine iodide) in nafion film was developed for the determination of Fe(III). The sensing film was homogeneous, transparent, and mechanically stable. Decrease of the absorbance measured at 518 nm was observed when the sensing film was immersed in a solution of Fe(III). The optimum response of the sensing film to Fe(III) was obtained in a solution with pH 4.0. Linear calibration curve over an Fe(III) concentration range of 1-30 ppm with a limit of detection of 0.71 ppm was obtained. Cd(II) is the major interference. The sensing film exhibited good stability for 2 months and high reproducibility. The proposed method was applied for the determination of Fe(III) in water samples with satisfactory results.

Keywords: iron(III), _nafion, optical sensing film, pseudocyanine iodide

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1086297

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1476

References:


[1] WHO. Iron in drinking-water. Background document for preparation of WHO guidelines for drinking-water quality. Geneva: WHO Press, Vol. 1, 2008, pp. 390-391.
[2] H. Bag, M. Lale and A. R. Turker, "Determination of iron and nickel by flame atomic absorption spectrophotometry after preconcentration on saccharomycescerevisiae immobilized sepiolite," Talanta. Vol. 47, 1998, pp. 689-696.
[3] A. Asan, M. Andac and I. Isildak, "Flow injection spectrofluorimetric determination of iron(III) in water using salicylic acid," Chemical Papers. Vol. 64 (4), 2010, pp. 424-428.
[4] T. Makino, K. Nakamura and K. Takahara, "A high-performance liquid immunoaffinity chromatography method for determining transferrinbound iron in serum," Clinica Chimica Acta. Vol. 412, 2011, pp. 914- 919.
[5] O. Oter, K. Ertekin, C. Kirimis, M. Koca, and M. Ahmedzade, "Characterization of a newly synthesized fluorescent benzofuran derivative and usage as a selective fiber optic sensor for Fe(III)," Sensors and Actuators B:Chemical. Vol. 122, 2007, pp. 450-456.
[6] N. Malçik, and P. Çaglar, "The operational parameter of a new fibreoptic sensor for ferric ions in aqueous media," Sensors and Actuators B: Chemical. Vol. 38, 1997, pp. 386-389.
[7] X. B. Zhang, G. Cheng, W. J. Zhang, G.L. Shen, and R.Q. Yu, "A fluorescent chemical sensor for Fe(III) based on blocking of intramolecular proton transfer of a quinazolinone derivative," Talanta. Vol. 71, 2007, pp. 171-177.
[8] P. P. Tofi├▒o, J. M. Barrero-Moreno and M. C. Pérez-Conde, "A flowthrough fluorescent sensor to determine Fe(III) and total inorganic iron," Talanta. Vol. 51, 1999, pp. 537-545.
[9] G. Ozturk, S. Alp, and K. Ertekin, "Fluorescence emission studied of 4- (2-furylmethylene)-2-phenyl-5-oxazolone embedded in polymer thin film and detection of Fe3+ ion," Dyes and Pigments. Vol. 72, 2007, pp. 150-156.
[10] M. Zhang, B. Zheng, H. Yuan, and D. Xiao, "A spectrofluorimetric sensor based on grape skin tissue for determination of iron(III)," Bulletin of the Chemical Society of Ethiopia. Vol. 24(1), 2010, pp. 31- 37.
[11] A. E. Greenberg, L. S. Clesceri, and A. D. Eaton, Standard Methods for Examination of Water and Wastewater, 18th ed., American public health association, Washington, 1992. pp. 328-329.