Functional Sample of the Portable Device for Fast Analysis of Explosives
Authors: A. Bumbová, J. Kellner, Z. Večeřa, V. Kahle, J. Navrátil
Abstract:
The construction of original functional sample of the portable device for fast analysis of energetic materials has been described in the paper. The portable device consisting of two parts – an original miniaturized microcolumn liquid chromatograph and a unique chemiluminescence detector – has been proposed and realized. In a very short time, this portable device is capable of identifying selectively most of military nitramine- and nitroesterbased explosives as well as inorganic nitrates occurring in trace concentrations in water or in soil. The total time required for the identification of extracts is shorter than 8 minutes.
Keywords: Chemiluminescence, microcolumn liquid chromatograph, nitramines, nitroesters, portable device.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1083527
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1514References:
[1] E. L. Holtoff, D. N.Stratis-Cullum, M. E. Hankus, A nanosensor for TNT detection based on molecularly imprinted polymers and surface enhanced raman scattering. Sensors, 2011, 11, pp. 2700-2714.
[2] J. G. Houston, G. R. Lotfu, Dietary exposure of flathead minnows to the explosives TNT and RDX and to the pesticide DDT using contaminated invertebrates. Int. J. Environ. Res. Public Health 2005, 2, pp. 286-292.
[3] Z.Veeefa, P. Mikugka, J. Kellner, J. Navratil, A. Langerova., Application of Portable Continuous Aerosol Concentrator. In Mathematical Methods and Techniques in Engineering & Environmental Science, Proceedings of the 4th WSEAS Conference on Sensors and Signals (SENSIG1 1). Catania, Sicily, Italy: WSEAS Press, 2011, pp. 271-276. ISBN 978-1-61804-046-6.
[4] Z. Friedel Biotransformation of military explosives. Researcher report of the project Ministry of Defence of the Czech Republic 2011, grant No. 0901 8 7150 R.
[5] A. B. Crockett, H. D. Craig, T. F. Jenkins, Field, Sampling and Selecting On-Site Analytical Methods for Explosives in Water; Report #EPA/600/S-99/002; United States Environmental Protection Agency: Las Vegas, NV, USA, 1999.
[6] V. Marinovic, S. Marinovic, M. Jovanovic, J. Jovanovic, S. Strbac, The electrochemical reduction of trinitrotoluene on a platinum wire modified by chemisorbed acetonitrile. J. Electroanal. Chem., 2010, 648, pp. 1-7.
[7] G. A. Eiceman, P. A. Stone, Peer reviewed: ion mobility spectrometers in national defense, Anal. Chem., 2004, vol. 76, no. 21, pp. 390-397.
[8] J. P. Smith, V. Hinson-Smith, The New Era of SAW Device, Anal. Chem., 2006, vol. 78, no. 11, pp. 3505-3507.
[9] J. V. Goodpaster, V. L. Mcguffin, Fluorescence quenching as an indirect detection method for nitrated explosives, Anal. Chem., 2001, vol. 73, no 9, pp. 2004-2011.
[10] M. S. Meaney, V. L. Mcguffin, Luminescence-based methods for sensing and detection of explosives, Anal. Bioanal. Chem., 2008, 391, pp. 2557-2576,
[11] E. Smith, G. Dent, Modem Raman Spectroscopy. A Practical Approach. Wiley, Chichester, 2005, pp. 2-8.