Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33093
Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time

Authors: Soo-young Ye, Gi-Ryon Kim, Dong-Keun Jung, Seong-wan Baik, Gye-rok Jeon

Abstract:

In this paper, algorithm estimating the blood pressure was proposed using the pulse transit time (PTT) as a more convenient method of measuring the blood pressure. After measuring ECG and pressure pulse, and photoplethysmography, the PTT was calculated from the acquired signals. Thereafter, the system to indirectly measure the systolic pressure and the diastolic pressure was composed using the statistic method. In comparison between the blood pressure indirectly measured by proposed algorithm estimating the blood pressure and real blood pressure measured by conventional sphygmomanometer, the systolic pressure indicates the mean error of ±3.24mmHg and the standard deviation of 2.53mmHg, while the diastolic pressure indicates the satisfactory result, that is, the mean error of ±1.80mmHg and the standard deviation of 1.39mmHg. These results are satisfied with the regulation of ANSI/AAMI for certification of sphygmomanometer that real measurement error value should be within the mean error of ±5mmHg and the standard deviation of 8mmHg. These results are suggest the possibility of applying to portable and long time blood pressure monitoring system hereafter.

Keywords: Blood pressure, Systolic, Diastolic, Pulse transit time.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1077837

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 6577

References:


[1] K. G. Ng and C. F. Small, "Survey of automated noninvasive blood pressure monitors", J. Clin. Eng., Vol. 19, pp.452-487, 1994.
[2] R. P. Kelly, C. S. Hayward, A. P. Avolio, M. F. O'Rourke, "Noninvasive determination of age-related changes in the human arterial pulse", Circulation, Vol. 80, pp.1652-1659, 1989.
[3] E.K. Park, S.M. Lee, Y.H. Han, et al., "A study on estimation of systolic blood pressure using PTT", J. Biomed. Eng. Res., Vol. 25, No. 6, pp. 605-609, 2004.
[4] J. Lass, K. Meigas, D. Karai, et al., "Continuous blood pressure monitoring during exercise using pulse wave transit time measurement", Proceedings of the 26th Annual International Conference of the IEEE EMBS, pp.2239-2242, 2004.
[5] X. F. Teng and Y. T. Zhang, "Continuous and Noninvasive Estimation of Arterial Blood Pressure Using a Plethysmographic Approach", Proceedings of the 25th Annual International Conference of the IEEE EMBS, pp.3153-3156, 2003.
[6] G. V. Marie, C. R. Lo and D. W. Johnston, "The relationship between pulse transit time and blood pressure", Psycholphysiology, Vol. 21, No. 5, pp.521-7, 1984.
[7] Gi Ryon Kim, Gwang Nyeon Lim, Byeong Cheol Choi, et al., "Implementation and evaluation of the sensor assessing pressure and photoplethysmogram", J. of the Korean Sensors Society, Vol. 15, No. 2, pp.00-00, 2006.