A Quantitative Analysis of GSM Air Interface Based on Radiating Columns and Prediction Model
Authors: K. M. Doraiswamy, Lakshminarayana Merugu, B. C. Jinaga
Abstract:
This paper explains the cause of nonlinearity in floor attenuation hither to left unexplained. The performance degradation occurring in air interface for GSM signals is quantitatively analysed using the concept of Radiating Columns of buildings. The signal levels were measured using Wireless Network Optimising Drive Test Tool (E6474A of Agilent Technologies). The measurements were taken in reflected signal environment under usual fading conditions on actual GSM signals radiated from base stations. A mathematical model is derived from the measurements to predict the GSM signal levels in different floors. It was applied on three buildings and found that the predicted signal levels deviated from the measured levels with in +/- 2 dB for all floors. It is more accurate than the prediction models based on Floor Attenuation Factor. It can be used for planning proper indoor coverage in multi storey buildings.Keywords: GSM air interface, nonlinear attenuation, multistory building, radiating columns, ground conduction and floor attenuation factor.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1329765
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1575References:
[1] K.M.Doraiswamy, Lakhminarayana Merugu and B.C.Jinaga, "Ground Conduction Enhancing GSM Air Interface Performance in Ground Floor and Practical Measurements" 2008 IEEE
[2] S.Y.Seidel and T.S. Rappaport, "914 MHz path loss prediction model for indoor wireless communications in multifloored buildings." IEEE Trans. Antennas and Propagation, vol. 40, pp. 207-217, Feb. 1992
[3] Supachai Phaiboon, "An Empirically Based Path Loss Model for Indoor Wireless Channels in Laboratory Building", Proceedings of IEEE TENCON-02.
[4] JIA Huaiyi, GONG Jian and LI Hongqing, "The analysis and research of the radio propagation models in multifloored buildings." 2002IEEE.
[5] Ashok Chandra, Ambuj Kumar and Prem Chandra, "Estimation of Path Loss Measurements Using Propagation Measurements at 900 MHz and 1.89 GHz in the corridors of a Multifloor Building" 1998 IEEE..
[6] Vijay K Garg, " IS - 95 CDMA and cdma2000, Cellular / PCS Systems Implementation," Pearson Education, Inc., 2002, pp. 238 - 241.
[7] Jules LeBel, "The development of a comprehensive Indoor propagation model" in Proc. IEEE Int. Symp. Personal Indoor, and Mobile Radio Commun (King-s College, London, UK), Sept. 1991.
[8] W. Honcharenko, H. L. Bertoni and J. Dailing, "Mechanisms Governing Propagation between Different Floors in Buildings." IEEE Trans. Antennas and Propagations, vol.41, No. 6, June 1993.
[9] Jean-Francois Lafortune and Michel Lecours, "Measurement and Modeling of Propagation Losses in a Building at 900 MHz," IEEE Transaction on Vehicular Technology, Vol. 39, No.2, May 1990.
[10] H. W. Arnold R. Murray and D. C. Cox, "815 MHz radio attenuation measured within two commercial buildings," IEEE Trans. Antennas Propagat., vol. 37, pp. 1335 - 1339, October 1989.