Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33093
Retaining Structural System Active Vibration Control
Authors: Ming-Hui Lee, Shou-Jen Hsu
Abstract:
This study presents an active vibration control technique to reduce the earthquake responses of a retained structural system. The proposed technique is a synthesis of the adaptive input estimation method (AIEM) and linear quadratic Gaussian (LQG) controller. The AIEM can estimate an unknown system input online. The LQG controller offers optimal control forces to suppress wall-structural system vibration. The numerical results show robust performance in the active vibration control technique.Keywords: Active vibration control, AIEM, LQG, Optimal control
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1074902
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1867References:
[1] T.T., Soong, and M.C., Costantinou, "Passive and active structural vibration control in civil engineering," Springer Verlag Wien-New York, 1994.
[2] S. Pourzeynali, H.H. Lavasani, A.H. Modarayi, "Active control of high rise building structures using fuzzy logic and genetic algorithms," Engineering Structures 29, pp.346-357, 2007
[3] U. Gabbert, T.N. Trajkov, H. Koppe, "Modeling, control and simulation of piezoelectric smart structures using finite element method and optimal LQ control," Facta universitatis, Series: Mechanics, Automatic Control and Robotics 3, pp.417-430, 2002.
[4] M. Aldawod, B. Samali, F. Naghdy, K.C.S. Kwok, Active control of along wind response of tall building using a fuzzy controller, Engineering Structures 23, pp.1512-1522, 2001.
[5] J.N., Yang, "Application of optimal control theory to civil engineering structures," Journal of Engineering Mechanics ASCE 101, pp.818-838, 1975.
[6] J.N., Yang, A. Akbarpour, and P. Ghaemmaghami, "New optimal control algorithms for structural control," Journal of Engineering Mechanics ASCE 113, pp.1369-1386, 1987.
[7] P.C., Tuan, S.C., Lee, and W.T., Hou, "An efficient on-line thermal input estimation method using Kalman Filter and recursive least square algorithm," Inverse Problem Eng., 5, pp.309-333, 1997.
[8] P.C., Tuan, and W.T., Hou, "Adaptive robust weighting input estimation method for the 1-D inverse heat conduction problem," Numer. Heat Transfer, 34, pp.439-456, 1998.
[9] C.C., Ji, S., Ay, and C.A., Liang, "Study on an estimation technique for the transverse impact of plates," International Journal for Numerical Methods in Engineering, Vol.50, pp.579-593, 2001.
[10] M. H., Lee, and T. C., Chen, "Blast Load Input Estimation of the Medium Girder Bridge using Inverse Method," Defense Science Journal Vol.58 (1), pp.46-56, 2008.
[11] T. C., Chen, and M. H., Lee, "Inverse active wind load inputs estimation of the multilayer shearing stress structure." Wind and Structures, An International Journal, Vol.11 (1), pp.19-33, 2008.
[12] T. C., Chen, and M. H., Lee, "Research on Moving Force Estimation of the Bridge Structure using the Adaptive Input Estimation Method," Electronic Journal of Structural Engineering, Vol. 8, pp.20-28, 2008.
[13] C., Deepankar, and C., Santiram, "Dynamic Active Earth Pressure on Retaining Structures," Sadhand, Vol.31, pp.721-730, 2006.
[14] P.C., Tuan, L.W., Fong, and W.T., Huang, "Analysis of On-Line Inverse Heat Conduction Problems," Journal of Chung Cheng Institute of Technology, Vol. 25(1), pp.59-73, 1996.
[15] P.C., Tuan, and W.T., Hou, "Adaptive robust weighting input estimation method for the 1-D inverse heat conduction problem," Numeral Heat Transfer, Vol.34, pp.439-456, 1998.
[16] H., Kwakernaak, and R., Sivan, Linear Optimal Control System, Wiley, New York, 1972.
[17] A.S., Veletsos, and A.H., Younan, "Dynamic modeling and response of soil-wall systems," Journal Geotectonic Engineering, ASCE, Vol.120, pp.2155-2179, 2000.
[18] Academia Sinica, Institute of Earth Sciences, [email protected]. edu.tw.