Using Seismic Base Isolation Systems in High-Rise Hospital Buildings and a Hybrid Proposal
Authors: E. Bakkaloğlu, N. Torunbalcı
Abstract:
Earthquakes are inevitable natural disasters in Turkey. Therefore, buildings must be prepared for this natural hazard. Especially in hospital buildings, earthquake resistance is an essential point because hospitals are one of the first places where people come after earthquake. Although hospital buildings are more suitable for horizontal architecture, it is necessary to construct and expand multi-story hospital buildings due to difficulties in finding suitable places as a result of excessive urbanization, difficulties in obtaining appropriate size land and decrease in suitable places and increase in land values. In Turkey, using seismic isolators in public hospitals, which are placed in first degree earthquake zone and have more than 100 beds, is made obligatory by general instruction. As a result of this decision, it may sometimes be necessary to construct seismic isolated multi-story hospital buildings in cities where those problems are experienced. Although there is widespread use of seismic isolators in Japan, there are few multi-story buildings in which seismic isolators are used in Turkey. As it is known, base isolation systems are the most effective methods of earthquake resistance, as the number of floors increases, the center of gravity moves away from the base in multi-story buildings, increasing the overturning effect and limiting use of these systems. In this context, it is aimed to investigate structural systems of multi-story buildings which are built using seismic isolation methods in the world. In addition to this, a working principle is suggested for the disseminating seismic isolator used in multi-story hospital buildings. The results to be obtained from the study will guide architects who design multi-story hospital buildings in their architectural designs, and engineers in terms of structural system design.
Keywords: Earthquake, energy absorbing systems, hospital, seismic isolation systems.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 23References:
[1] Komuro, T., Nishikawa, Y., Kimura, Y., & Isshiki, Y. (2005). Development and realization of base isolation system for high-rise buildings. Journal of Advanced Concrete Technology, 3(2), 233-239.
[2] Sağlam, D. (2017). Sismik İzolatörlerin Yüksek Binalarda Deprem Davranışına Etkisi. (Master’s Thesis, YTÜ, FBE)
[3] Kikuchi, T., Takeuchi, T., Fujimori, S., & Wada, A. (2014). Design of seismic isolated tall building with high aspect-ratio. International Journal of High-Rise Buildings, 3(1), 1-8.
[4] Muramatsu, Y., Nishikawa, I.Kawabata, I., Takayama, ve Kimura, Y. (2001). ‘’Tensile Property of Large-sized Natural Rubber Bearing.’’ AIJ Journal of Technology and Design, (12), 53-56.
[5] Martelli, A. (2007). Seismic isolation and energy dissipation: worldwide application and perspectives
[6] Nakagawa, K., Shimazaki D., Yoshida, S., & Okada, K. (2015). Application of seismic isolation systems in Japanese High-Rise Buildings. CBUTH Journal, 2015 Issue II, 36-40.
[7] Becker, T. C., Yamamoto, S., Hamaguchi, H., Higashino, M., & Nakashima, M. (2015). Application of isolation to high-rise buildings: a Japanese design case study through a US design code lens. Earthquake Spectra, 31(3), 1451-1470.
[8] Tsuneki, Y., Torii, S., Murakami, K., & Sueoka, T. (2008, October). Middle-story isolated structural system of high-rise building. In Proceedings of 14th World Conference on Earthquake Engineering.
[9] Tasaka, M., Mori, N., Yamamoto, H., Murakami, K., & Sueoka, T. (2008). Applying seismic isolation to buildings in Japan—retrofitting and middle-story isolation. 2008: 18th Analysis and Computation Specialty Conference (pp. 1-11).
[10] Sueoka, T., Torii, S., & Tsuneki, Y. (2004, August). The application of response control design using middle-story isolation system to high-rise building. In 13th World Conference on Earthquake Engineering.
[11] Kumano, T., Yoshida, S., & Saburi, K. (2017). Structural Design of Nakanoshima Festival Tower West that Achieved High-Grade Seismic Performance, 6(3), 217–226. https://doi.org/10.21022/IJHRB.2017.6.3.217
[12] Okada, K., & Yoshida, S. (2014). Structural design of Nakanoshima festival tower. Internationl Journl of High-Rise Buildings
[13] Shimazaki, D., & Nakagawa, K. (2015). Seismic Isolation Systems Incorporating with RC Core Walls and Precast Concrete Perimeter Frames-Shimizu Corporation Tokyo Headquarter. International Journal of High-Rise Buildings, 4(3), 181-189.