First Cracking Moments of Hybrid Fiber Reinforced Polymer-Steel Reinforced Concrete Beams
Authors: Saruhan Kartal, Ilker Kalkan
Abstract:
The present paper reports the cracking moment estimates of a set of steel-reinforced, Fiber Reinforced Polymer (FRP)-reinforced and hybrid steel-FRP reinforced concrete beams, calculated from different analytical formulations in the codes, together with the experimental cracking load values. A total of three steel-reinforced, four FRP-reinforced, 12 hybrid FRP-steel over-reinforced and five hybrid FRP-steel under-reinforced concrete beam tests were analyzed within the scope of the study. Glass FRP (GFRP) and Basalt FRP (BFRP) bars were used in the beams as FRP bars. In under-reinforced hybrid beams, rupture of the FRP bars preceded crushing of concrete, while concrete crushing preceded FRP rupture in over-reinforced beams. In both types, steel yielding took place long before the FRP rupture and concrete crushing. The cracking moment mainly depends on two quantities, namely the moment of inertia of the section at the initiation of cracking and the flexural tensile strength of concrete, i.e. the modulus of rupture. In the present study, two different definitions of uncracked moment of inertia, i.e. the gross and the uncracked transformed moments of inertia, were adopted. Two analytical equations for the modulus of rupture (ACI 318M and Eurocode 2) were utilized in the calculations as well as the experimental tensile strength of concrete from prismatic specimen tests. The ACI 318M modulus of rupture expression produced cracking moment estimates closer to the experimental cracking moments of FRP-reinforced and hybrid FRP-steel reinforced concrete beams when used in combination with the uncracked transformed moment of inertia, yet the Eurocode 2 modulus of rupture expression gave more accurate cracking moment estimates in steel-reinforced concrete beams. All of the analytical definitions produced analytical values considerably different from the experimental cracking load values of the solely FRP-reinforced concrete beam specimens.
Keywords: Cracking moment, four-point bending, hybrid use of reinforcement, polymer reinforcement.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.3455727
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 824References:
[1] M. A. Aiello and L. Ombres, “Structural performances of concrete beams with hybrid (fiber-reinforced polymer-steel) reinforcements,” Journal of Composites for Construction, vol. 6, no. 2, pp. 133-140, May 2002.
[2] H. Y. Leung and R. V. Balendran, “Flexural behaviour of concrete beams internally reinforced with GFRP rods and steel rebars,” Structural Survey, vol. 21, no. 4, pp. 146-157, 2003.
[3] W. Qu, X. Zhang and H. Huang, “Flexural behavior of concrete beams reinforced with hybrid (GFRP and steel) bars,” Journal of Composites for Construction, vol. 13, no. 5, pp. 350-359, Sep. 2009.
[4] D. Lau and H. J. Pam, “Experimental study of hybrid FRP reinforced concrete beams,” Engineering Structures, vol. 32, pp. 3857-3865, 2010.
[5] M. A. Safan, “Flexural behavior and design of steel-GFRP reinforced concrete beams,” ACI Materials Journal, vol. 110, no. 6, pp.-677-685, Nov.-Dec. 2013.
[6] L. Yinghao and Y. Yong, “Arrangement of hybrid rebars on flexural behavior of HSC beams,” Composites: Part B, vol. 45, pp. 22-31, 2013.
[7] M. Yaz, “The Effect of GFRP Bars on Flexural Behaviour in Reinforced Concrete Beams,” Graduate School of Natural and Applied Sciences, Department of Civil Engineering, M. Sc. Thesis, Kirikkale University, Aug. 2014.
[8] Comité Européen de Normalisation (CEN), “prEN 1992-1-1:2004 (Eurocode 2): Design of Concrete Structures - Part 1-1: General Rules and Rules for Buildings,” European Committee for Standardization (CEN), Brussels, Belgium, 2004.
[9] ACI Committee 318M, “Building Code Requirements for Structural Concrete (ACI 318M-11) and Commentary,” American Concrete Institute, Farmington Hills, Michigan, U.S.A., 2011.
[10] ASTM C78 / C78M-18, “Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading),” ASTM International, West Conshohocken, PA, 2018.