The aim of presented research was to improve numerical predictions of air parameters distribution in the actual natatorium by the selection of calculation formula of mass flux of moisture emitted from the pool. Selected correlation should ensure the best compliance of numerical results with the measurements' results of these parameters in the facility. The numerical model of the natatorium was developed, for which boundary conditions were prepared on the basis of measurements' results carried out in the actual facility. Numerical calculations were carried out with the use of ANSYS CFX software, with six formulas being implemented, which in various ways made the moisture emission dependent on water surface temperature and air parameters in the natatorium. The results of calculations with the use of these formulas were compared for air parameters' distributions: Specific humidity, velocity and temperature in the facility. For the selection of the best formula, numerical results of these parameters in occupied zone were validated by comparison with the measurements' results carried out at selected points of this zone.

Keywords: Experimental validation, indoor swimming pool, moisture emission, natatorium, numerical calculations, CFD, thermal and humidity conditions, ventilation.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1123691

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1498

References:


[1] Z. Li, P. K. Heiselberg, "CFD simulations for water evaporation and airflow movement in swimming baths", Instituttet for Bygningsteknik, Aalborg Universitet (available on the website http://vbn.aau.dk/files/45855153/VENTInet_nr._14.pdf), 2005,
[2] P. Koper, B. Lipska, W. Michnol, "Assessment of thermal comfort in an indoor swimming-pool making use of the numerical prediction CFD", Architecture Civil Engineering Environment (ACEE), vol. 3 no. 3, p. 95-103, 2010.
[3] M. M. Abo Elazm, A. I. Shahata, “Numerical and Field Study of the Effect of Air Velocity and Evaporation Rate on Indoor Air Quality in Enclosed Swimming Pools”, International Review of Mechanical Engineering (IREME), 9(1), p. 97-103, 2015.
[4] P. Ciuman, B. Lipska, G. Burda, “Numerical Modelling of Air Distribution in the Natatorium Supported by the Experiment”, Proceedings of the World Congress on Mechanical, Chemical, and Material Engineering (MCM 2015), 2015.
[5] A. Palmowska, B. Lipska, “The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena”, Proceedings of the World Congress on Mechanical, Chemical, and Material Engineering (MCM 2015), 2015.
[6] http://tinyurl.com/pm5hyau, consulted 4 Oct. 2015.
[7] W. H. Carrier, “The temperature of evaporation”, ASHVE Trans., 24, p. 25-50, 1918.
[8] C. C. Smith, G. O. G. Lof, R. W. Jones, “Rates of evaporation from swimming pools in active use”, ASHRAE Trans., 104 (1A), p. 514-523, 1999.
[9] ASHRAE Handbook - HVAC Applications, ASHRAE, Atlanta, GA, 1999.
[10] VDI 2089 Blatt 1 Technische Gebäudeausrüstung von Schwimmbädern–Hallenbäder.
[11] K. Biasin, W. Krumme, “Die Wasserverdunstung in einem Innenschwimmbad”, Electrowaerme International, 32 (A3), p.115-129, 1974.
[12] M. M. Shah, “Prediction of evaporation from occupied indoor swimming pools”, Energy and Buildings, 35, p. 707-713, 2003.