Contribution of the Cogeneration Systems to Environment and Sustainability

Authors: Kemal Çomakli, Uğur Çakir, Ayşegül Çokgez Kuş, Erol Şahin

Abstract:

A lower consumption of thermal energy will contribute not only to a reduction in the running costs, but also in the reduction of pollutant emissions that contribute to the greenhouse effect. Cogeneration or CHP (Combined Heat and Power) is the system that produces power and usable heat simultaneously by decreasing the pollutant emissions and increasing the efficiency. Combined production of mechanical or electrical and thermal energy using a simple energy source, such as oil, coal, natural or liquefied gas, biomass or the sun; affords remarkable energy savings and frequently makes it possible to operate with greater efficiency when compared to a system producing heat and power separately. This study aims to bring out the contributions of cogeneration systems to the environment and sustainability by saving the energy and reducing the emissions. In this way we made a comprehensive investigation in the literature by focusing on the environmental aspects of the cogeneration systems. In the light of these studies we reached that, cogeneration systems must be consider in sustainability and their benefits on protecting the ecology must be investigated.

Keywords: Sustainability, cogeneration systems, energy economy, energy saving.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1108194

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2663

References:


[1] Uğur Cakir, Kemal Comakli, Fikret Yuksel. 2012. The role of cogeneration systems in sustainability of energy. Energy Conversion and Management. 63 (2012) 196–202
[2] Can F. O., Celik N., Dagtekin İ. 2009. Energetic and exergetic– economic analyses of a cogeneration ther-mic power plant in Turkey. International Communications in heat and mass transfer, 36-1044-1049
[3] Abusoglu A, Kanoglu M. 2009. Exergetic and thermodynamic analyses of diesel engine powered cogeneration. Part 1. Formulations. Applied Thermal Engineering. 2009; 29:234–41.
[4] Gibbons 1983. Industrial and commercial cogeneration. http://www.princeton.edu/~ota/disk3/1983/8311/831108.PDF, chapter 6
[5] Martin Pehnt. 2008. Environmental impacts of distributed energy systems-The case of micro cogeneration. Environmental science & policy 11 (2008) 25–37 7
[6] Thilak Raj N, Iniyan S, Goic R. A review of renewable energy based cogeneration Technologies. Renew Sust Energy Rev 2011;15:3640–8.
[7] Y.June Wu VE Marc A. Rosen. 1999. Assessing and optimizing the economic and environmental impacts of cogeneration/district energy systems using an energy equilibrium model. Applied Energy Volume 62, Issue 3, Pages 141–154
[8] Goktun S. Solar powered cogeneration system for air conditioning and refrigeration. Energy 1999;24:971–7
[9] Morgan D. Bazilian, Frederik Leenders, B.G.C Van der Ree, Deo Prasad. 2001. Photovoltaic cogeneration in the built environment Solar Energy Volume 71, Issue 1, 2001, Pages 57–69
[10] M. Gariglio F., De Benedictisi, M. Calì G. Orsello. 2009. Experimental activity on two tubular solid oxide fuel cell cogeneration plants in a real industrial environment International. Journal of Hydrogen Energy Volume 34, Issue 10, May 2009, Pages 4661–4668
[11] Hollick JC. 1998. Solar cogeneration panels. Renewable Energy 1998; 15:195–200.
[12] Lindenberger D, Bruckner T, Groscurth H-M, Kummel R. 2000.Optimization of solar district heating systems: seasonal storage heat pumps and cogeneration. Energy; 25:591.
[13] Marc A. Rosen. 2008. Allocating carbon dioxide emissions from cogeneration systems: descriptions of selected output-based methods. Journal of Cleaner Production. Volume 16, Issue 2, Pages 171–177
[14] Mancarella P. 2009. Cogeneration systems with electric heat pumps: energy-shifting properties and equivalent plant modeling. Energy Conversion Management 2009;50:1991–9.
[15] R. Soltani P., Mohammadzadeh Keleshtery, M. Vahdati, M.H. Khoshgoftar Manesh, M.A. Rosen., M. Amidpour. 2014. Multi-objective optimization of a solar-hybrid cogeneration cycle:Application to CGAM problem. Energy Conversion and Management 81 (2014) 60–71
[16] Malinowska W, Malinowski L. Parametric study of exergetic efficiency of a small-scale cogeneration plant incorporating a heat pump. Applied Thermal Engineering. 2003;23:459–72.
[17] M. Hasan Nia, A. Abbas Nejad, A.M. Goudarzi, M. Valizadeh, P. Samadian. 2014 Cogeneration solar system using thermoelectric module and fresnel lens. Energy Conversion and Management 84 (2014) 305– 310.
[18] Rafael Galvão J, Leitão Augusto S, Silva Malheiro S, Gaio Manuel T. Cogeneration supply by bio-energy for a sustainable hotel building management system. Fuel Process Technol 2011;92:284–9.
[19] Madlener R, Bachhiesl M. Socio-economic drivers of large urban biomass cogeneration sustainable energy supply for Austria’s capital Vienna. Energy Policy 2007;35:1075–87.
[20] Burer M, Tanaka K, Favrat D, Yamada K. Multi-criteria optimization of a district cogeneration plant integrating a solid oxide fuel cell–gas turbine combined cycle, heat pumps and chillers. Energy 2003; 28: 497– 518.
[21] Jeff Smithers. 2014. Review of sugar cane trash recovery systems for energy cogeneration in South Africa. Renewable and Sustainable Energy Reviews 32(2014)915–925
[22] Dario Buoro, Piero Pinamonti, Mauro Reini. 2014. Optimization of a Distributed Cogeneration System with solar district heating. Applied Energy 124 (2014) 298–308
[23] Marta Serrano Delgado, Esteban Calvo Bernad, J. Ignacio García Palacín.2013. Cogeneration process modelling in a paper factory Procedia Engineering 63 ( 2013 ) 966 – 972.