Influence of the Flow Rate Ratio in a Jet Pump on the Size of Air Bubbles
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Influence of the Flow Rate Ratio in a Jet Pump on the Size of Air Bubbles

Authors: L. Grinis, N. Lubashevsky, Y. Ostrovski

Abstract:

In wastewater treatment processes, aeration introduces air into a liquid. In these systems, air is introduced by different devices submerged in the wastewater. Smaller bubbles result in more bubble surface area per unit of volume and higher oxygen transfer efficiency. Jet pumps are devices that use air bubbles and are widely used in wastewater treatment processes. The principle of jet pumps is their ability to transfer energy of one fluid, called primary or motive, into a secondary fluid or gas. These pumps have no moving parts and are able to work in remote areas under extreme conditions. The objective of this work is to study experimentally the characteristics of the jet pump and the size of air bubbles in the laboratory water tank. The effect of flow rate ratio on pump performance is investigated in order to have a better understanding about pump behavior under various conditions, in order to determine the efficiency of receiving air bubbles different sizes. The experiments show that we should take care when increasing the flow rate ratio while seeking to decrease bubble size in the outlet flow. This study will help improve and extend the use of the jet pump in many practical applications.

Keywords: Jet pump, air bubbles size, retention time.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1106661

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2993

References:


[1] H. J. Hwang, M. K. Stenstrom, “Water Pollution Control Federation”, 57, 12, 1985.
[2] S. Levitsky, L. Grinis. “Water Oxygenation in an Experimental Aerator with Different Air/Water Interaction Patterns”. HAIT Journal of Science and Engineering 2, pp. 242-253, 2005.
[3] R. R. Stickney, “Encyclopedia of Aquaculture”, World Aquaculture Society, USA, 2000.
[4] A. A. Saker, H. Z. Hassan. “Study of the Different Factors That Influence Jet Pump Performance”. Open Journal of Fluid Dynamics, 3, pp. 44-49, 2013.
[5] V. P. Sharma, S. Kumaraswamy, A. Mani. “Effect of Various Nozzle Profiles on Performance of a Two Phase Flow Jet Pump”. World Academy of Science, Engineering and Technology 6, pp.470-476, 2012.
[6] A. Vazquez, R.M. Sanchez. “A Look at Three Measurement Techniques for Bubble Size Determination”. Experimental Thermal and Fluid Science 30, pp.49–57, 2005.
[7] K. K. Al-Ahmady. “Mathematical Model for Calculating Oxygen Mass Transfer Coefficient in Diffused Air Systems”. Al-Rafidain Engineering. 19, pp. 43-54, 2011.
[8] Y. L. Wu, Q. J. Xiang, “Study on Bubble Sizes in a Down-Flow liquid Jet Gas Pump”. Earth and Environmental Science 15, pp. 51-60, 2012.