Abstract:
A three-dimensional numerical model of thermoelectric generator (TEG) modules attached to a large chimney plate is proposed and solved numerically using a control volume based finite difference formulation. The TEG module consists of a thermoelectric generator, an elliptical pin-fin heat sink, and a cold plate for water cooling. In the chimney, the temperature of flue gases is 450-650K. Although the TEG hot-side temperature and thus the electric power output can be increased by inserting an elliptical pin-fin heat sink into the chimney tunnel to increase the heat transfer area, the pin fin heat sink would cause extra pumping power at the same time. The main purpose of this study is to analyze the effects of geometrical parameters on the electric power output and chimney pressure drop characteristics. The effects of different operating conditions, including various inlet velocities (Vin= 1, 3, 5 m/s), inlet temperatures (Tgas = 450, 550, 650K) and different fin height (0 to 150 mm) are discussed in detail. The predicted numerical data for the power vs. current (P-I) curve are in good agreement (within 11%) with the experimental data.
Keywords: Thermoelectric generator, Waste heat recovery, Elliptical pin-fin heat sink.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1100490
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2452References:
[1] K. Ono, R. O. Suzuki, "Thermoelectric power generation: Converting low-grade heat into electricity," JOM, Vol. 50, pp.49-51, 1998.
[2] D. M. Rowe, "Thermoelectrics, an environmentally-friendly source of electrical power," Renewable energy, Vol 16, pp.1251-1256, 1999.
[3] E. F. Thacher, B. T. Helenbrook, K. A. Karri, C. J. Richter, “Testing of an automobile exhaust thermoelectric generator in a light truck,” Proceedings of the Institution of Mechanical Engineers - Part D: Journal of Automobile Engineering, Vol. 221, pp. 95-107, 2007.
[4] D. Champier, A. Bedecarrats, B. Rivaletto, H. Strub. "Thermoelectric power generation from biomass cook stoves," Energy, Vol.35, pp.935-942, 2010.
[5] K. Qiu, A. C. S. Hayden, “Development of a Thermoelectric Self-Powered Residential Heating System,” Journal of Power Sources, Vol. 180, pp. 884-889, 2008.
[6] Y. Y. Hsiao, W. C. Chang, S. L. Chen, “A Mathematic Model of Thermoelectric Module with Applications on Waste Heat Recovery from Automobile Engine,” Energy, Vol. 35, pp. 1447-1454, 2010.
[7] M. Behnia, D. Copeland, D. Soodphakdee, “A Comparison of Heat Sink Geometries for Laminar Forced Convection: Numerical Simulation of Periodically Developed Flow,” Thermal and Thermomechanical Phenomena in Electronic Systems, 1998. ITHERM '98. The Sixth Intersociety Conference on, pp. 310-315, 1998.
[8] Q. L. Li, Z. Chen, “Heat transfer and pressure drop characteristics in rectangular channels with elliptic pin fins,“ International Journal of Heat and Fluid Flow, Vol. 19, Issue 3, pp. 245-250, 1998.
[9] J. Y. Jang, Y. C. Tsai, “Optimization of Thermoelectric Generator Module Spacing and Spreader Thickness Used in a Waste Heat Recovery System,” Applied Thermal Engineering, Vol. 51, pp. 677-689, 2013.
[10] J. Y. Jang, Y. C. Tsai, C. W. Wu, “A Study of 3-D Numerical Simulation and Comparison with Experimental Results on Turbulent Flow of Venting Flue Gas Using Thermoelectric Generator Modules and Plate Fin Heat Sink,” Energy, Vol. 53, pp 270-281, 2013.