Abstract:

The seismic responses of steel buildings with semirigid post-tensioned connections (PC) are estimated and compared with those of steel buildings with typical rigid (welded) connections (RC). The comparison is made in terms of global and local response parameters. The results indicate that the seismic responses in terms of interstory shears, roof displacements, axial load and bending moments are smaller for the buildings with PC connection. The difference is larger for global than for local parameters, which in turn varies from one column location to another. The reason for this improved behavior is that the buildings with PC dissipate more hysteretic energy than those with RC. In addition, unlike the case of buildings with WC, for the PC structures the hysteretic energy is mostly dissipated at the connections, which implies that structural damage in beams and columns is not significant. According to these results, steel buildings with PC are a viable option in high seismicity areas because of their smaller response and self-centering connection capacity as well as the fact that brittle failure is avoided.

Keywords: Inter-story drift, Nonlinear time-history analysis, Post-tensioned connections, Steel buildings.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1099898

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2171

References:


[1] Ricles, J.M., Sause, R., Garlock, M.M. and Zhao, C. 2001. Posttensioned seismic-resistant connections for steel frames, ASCE Journal of Structural Engineering, Vol. 127, No. 2, p. 113-121.
[2] Ricles, J.M., Sause, R., Peng, S.W. and Lu, L.W. 2002. Experimental evaluation of earthquake resistant post-tensioned steel connections, ASCE Journal of Structural Engineering, Vol. 128, No. 7, p. 850-859.
[3] Christopoulos, C., Filiatrault, A. &Uang, C.M. 2002a. Self-centering post-tensioned energy dissipating (PTED) steel frames for seismic regions, University of California, Report No. SSRP-2002/06.
[4] Christopoulos, C. &Filiatrault, A.. 2002b. Seismic response of posttensioned energy dissipating moment resisting steel frames, Proceedings of the 12th European Conference on Earthquake Engineering, London, UK, paper No. 61.
[5] Garlock, M, Ricles, J., &Sause, R. 2005. Experimental studies on fullscale post-tensioned steel connections. Journal of Structural Engineering, ASCE, v 131, n 3, p438-448.
[6] Garlock, M, Sause, R. &Ricles, J. 2007. Behavior and design of posttensioned steel frames system. Journal of Structural Engineering, ASCE v 133, n 3, p 389.
[7] Garlock, M, Sause, R. &Ricles, J. 2008. Influence of design parameter on seismic response of post-tensioned steel MRF systems. Engineering Structures, Vol. 30, pp.1037-1047.
[8] Ricles, J.M., Sause, R., Lin, Y.-C. andSeo, C.-Y. (2010). “Self- Centering Moment Connections for Damage-Free Seismic Response of Steel MRFs”, 2010 Structures Congress, p. 955-966.
[9] Rojas, P., Suárez, D.C., Ricles, J.M. and Sause, R. (2012). “Seismic evaluation of an eight story building with self-centering steel moment resisting frames and flange friction devices”, 15WCEE Lisboa 2012.
[10] López-Barraza, A., Ruiz, S. E., Bojórquez, E. & Reyes-Salazar, A. (2012a). “Seismic performance of steel frames with post-tensioned connections”, 15WCEE Lisboa 2012.
[11] López-Barraza, A., Ruiz, S. E., Bojórquez, E. & Reyes-Salazar, A. (2012b). “Seismic energy demands on steel framed structures with rigid and, alternatively, with post-tensioned semi-rigid connections”, Stessa 2012.
[12] Carr A. RUAUMOKO (2011), Inelastic Dynamic Analysis Program, University of Cantenbury, Department of Civil Engineering
[13] Richard, R.M. (1993), “Moment-rotation curves for partially restrained connections”, PRCONN, RMR Design Group, Tucson, Arizona.
[14] FEMA 350 (2000), Federal Emergency Management Agency, Report 350 “Recommended seismic design criteria for new steel moment-frame buildings”, Washington, D.C.
[15] UBC (1994), Structural Engineering Design Provisions, Uniform Building Code, Volume 2, International Conference of Building Officials.
[16] BOCA (1993), 12th Edition Building Officials & Code Administration International Inc., National Building Code.