Electromagnetic Interference Shielding Characteristics for Stainless Wire Mesh and Number of Plies of Carbon Fiber Reinforced Plastic
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Electromagnetic Interference Shielding Characteristics for Stainless Wire Mesh and Number of Plies of Carbon Fiber Reinforced Plastic

Authors: Min Sang Lee, Hee Jae Shin, In Pyo Cha, Hyun Kyung Yoon, Seong Woo Hong, Min Jae Yu, Hong Gun Kim, Lee Ku Kwac

Abstract:

In this paper, the electromagnetic shielding characteristics of an up-to-date typical carbon filler material, carbon fiber used with a metal mesh were investigated. Carbon fiber 12k-prepregs, where carbon fibers were impregnated with epoxy, were laminated with wire meshes, vacuum bag-molded and hardened to manufacture hybrid-type specimens, with which an electromagnetic shield test was performed in accordance with ASTM D4935-10, through which was known as the most excellent reproducibility is obtainable among electromagnetic shield tests. In addition, glass fiber prepregs whose electromagnetic shielding effect were known as insignificant were laminated and formed with wire meshes to verify the validity of the electromagnetic shield effect of wire meshes in order to confirm the electromagnetic shielding effect of metal meshes corresponding existing carbon fiber 12k-prepregs. By grafting carbon fibers, on which studies are being actively underway in the environmental aspects and electromagnetic shielding effect, with hybrid-type wire meshes that were analysed through the tests, in this study, the applicability and possibility are proposed.

Keywords: Carbon Fiber Reinforced Plastic (CFRP), Glass Fiber Reinforced Plastic (GFRP), Stainless Wire Mesh, Electromagnetic Shielding.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1099192

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2755

References:


[1] H. G. Kim, H. J. Shin, G. C. Kim, H. J. Park, H. J. Moon, and L. K. Kwac, “Electromagnetic interference shielding characteristics for orientation angle and number of plies of carbon fiber reinforced plastic,” Carbon Letter, vol. 15, no. 4, pp. 268-276, Aug. 2014.
[2] G. H. Park, Study on the Electromagnetic Shielding Effectiveness of AP(ACCESS POINT) Using Carbon Composites, A Thesis for a degree of master, Graduate School, Jeonju University, Korea, 2014.
[3] M. S. Lee, H. G. Kim, I. P. Cha, G. H. Park, H. D. Song, L. K. Kwac, “A study on the electromagnetic shielding effectiveness of using carbon and wire mesh,” The Korean Society of Manufacturing Technology Engineers, 2014.
[4] Y. J. Cha, “The Analysis of Mechanical Strength and Electromagnetic Shielding of Carbon Composite Meterials using Wire Mesh”, A Thesis for a degree of master, Graduate School, Jeonju University, Korea, 2014.
[5] J. S. Bae, “A Study the Electromagnetic Interference Shielding Characteristics of Fiber Reinforced Composites with Hybrid Conductive Filter”, A Thesis for a degree of doctorate, Graduate School, Chosun University. Korea, 2010.
[6] G. Y. Han, “Electromagnetic Interference Shielding Effect of Fiber Reinforced Composites with Stainless Fiber Conductive Filler”, Journal of the Korean Society for Precision Engineering,Vol 27, No. 7, pp-71-78, 2010
[7] O. H. Lee, “Study on the Electromagnetic Interference Properties of Fiber Reinforced Polymer Composites with Carbon Nanotubes”, A This is for a degree of scholar, Graduate School, Myong Ji University. Korea, Vol 620, No. 20, pp-61-63,2009