Limiting Fiber Extensibility as Parameter for Damage in Venous Wall
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32813
Limiting Fiber Extensibility as Parameter for Damage in Venous Wall

Authors: Lukas Horny, Rudolf Zitny, Hynek Chlup, Tomas Adamek, Michal Sara

Abstract:

An inflation–extension test with human vena cava inferior was performed with the aim to fit a material model. The vein was modeled as a thick–walled tube loaded by internal pressure and axial force. The material was assumed to be an incompressible hyperelastic fiber reinforced continuum. Fibers are supposed to be arranged in two families of anti–symmetric helices. Considered anisotropy corresponds to local orthotropy. Used strain energy density function was based on a concept of limiting strain extensibility. The pressurization was comprised by four pre–cycles under physiological venous loading (0 – 4kPa) and four cycles under nonphysiological loading (0 – 21kPa). Each overloading cycle was performed with different value of axial weight. Overloading data were used in regression analysis to fit material model. Considered model did not fit experimental data so good. Especially predictions of axial force failed. It was hypothesized that due to nonphysiological values of loading pressure and different values of axial weight the material was not preconditioned enough and some damage occurred inside the wall. A limiting fiber extensibility parameter Jm was assumed to be in relation to supposed damage. Each of overloading cycles was fitted separately with different values of Jm. Other parameters were held the same. This approach turned out to be successful. Variable value of Jm can describe changes in the axial force – axial stretch response and satisfy pressure – radius dependence simultaneously.

Keywords: Constitutive model, damage, fiber reinforcedcomposite, limiting fiber extensibility, preconditioning, vena cavainferior.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1077329

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1426

References:


[1] J. V. Psaila, and J. Melhuish, "Viscoelastic properties and collagen content of the long saphenous vein in normal and varicose veins," B. J. Surg., vol. 76, no. 1, pp. 37-40, January 1989.
[2] T. Azuma, and M. Hasegawa, "Distensibility of the vein: From the architectural point of view", Biorheology, vol. 10, pp. 469-479, 1973.
[3] V. Milesi, A. Rebolledo, F. A. Paredes, et al., "Mechanical properties of human saphenosu veins from normotensive and hypertensive patients," Ann. Thorac. Surg., vol. 66, no. 2, pp. 455-461, August 1998.
[4] R. L. Wesly, R. N. Vaishnav, J. C. Fuchs, D. J. Patel, and J. C. Greenfield, Jr., "Static linear and nonlinear elastic properties of normal and arterialized venous tissue in dog and man," Circ. Research, vol. 37, no. 4, pp. 509-520, 1975.
[5] H. W. Weizsacker, "Passive elastic properties of the rat abdominal vena cava," Pfluger Archs., vol. 412, no. 1-2, pp. 147-154, July 1988.
[6] R. Rezakhaniha, and N. Stergiopulos, "A structural model of the venous wall considering elastin anisotropy," J. Biomech. Eng. - Trans. ASME, vol. 130, no. 3, article no. 031017, Jun 2008.
[7] C. O. Horgan, and G. Saccomandi, "A description of arterial wall mechanics using limiting chain extensibility constitutive models," Biomechan. Model. Mechanobiol., vol. 1, no. 4, pp. 251-266, Aprile 2003.
[8] C. O. Horgan, and G. Saccomandi, "A new constitutive theory for fiber- reinforced incompressible nonlinear elastic solids," J. Mech. Phys. Solids, vol. 53, no. 9, pp. 1985-2015, September 2005.
[9] A. N. Gent, "New constitutive relation for rubber," Rub. Chem. Technol., vol. 69, no. 1, pp. 59-61, Mach-April 1996.
[10] G. A. Holzapfel, Nonlinear solid mechanics - A continuum approach for engineering. Chichester: John Wiley & Sons, 2000, ch. 6.
[11] L. Horny, R. Zitny, and H. Chlup, "Strain energy function for arterial walls based on limiting fiber extensibility," Proceedings of 4th European Congress for Medical and Biomedical Engineering 2008, 23-27 Nov 2008 Antwerp, Belgium, IFBME (Accepted for publication).