Search results for: dose rate
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2951

Search results for: dose rate

2861 Determination of Strain Rate Sensitivity (SRS) for Grain Size Variants on Nanocrystalline Material Produced by ARB and ECAP

Authors: P. B. Sob, A. A. Alugongo, T. B. Tengen

Abstract:

Mechanical behavior of 6082T6 aluminum is investigated at different temperatures. The strain rate sensitivity is investigated at different temperatures on the grain size variants. The sensitivity of the measured grain size variants on 3-D grain is discussed. It is shown that the strain rate sensitivities are negative for the grain size variants during the deformation of nanostructured materials. It is also observed that the strain rate sensitivities vary in different ways with the equivalent radius, semi minor axis radius, semi major axis radius and major axis radius. From the obtained results, it is shown that the variation of strain rate sensitivity with temperature suggests that the strain rate sensitivity at the low and the high temperature ends of the 6082T6 aluminum range is different. The obtained results revealed transition at different temperature from negative strain rate sensitivity as temperature increased on the grain size variants.

Keywords: Nanostructured materials, grain size variants, temperature, yield stress, strain rate sensitivity.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1796
2860 Identifying Knowledge Gaps in Incorporating Toxicity of Particulate Matter Constituents for Developing Regulatory Limits on Particulate Matter

Authors: Ananya Das, Arun Kumar, Gazala Habib, Vivekanandan Perumal

Abstract:

Regulatory bodies has proposed limits on Particulate Matter (PM) concentration in air; however, it does not explicitly indicate the incorporation of effects of toxicities of constituents of PM in developing regulatory limits. This study aimed to provide a structured approach to incorporate toxic effects of components in developing regulatory limits on PM. A four-step human health risk assessment framework consists of - (1) hazard identification (parameters: PM and its constituents and their associated toxic effects on health), (2) exposure assessment (parameters: concentrations of PM and constituents, information on size and shape of PM; fate and transport of PM and constituents in respiratory system), (3) dose-response assessment (parameters: reference dose or target toxicity dose of PM and its constituents), and (4) risk estimation (metric: hazard quotient and/or lifetime incremental risk of cancer as applicable). Then parameters required at every step were obtained from literature. Using this information, an attempt has been made to determine limits on PM using component-specific information. An example calculation was conducted for exposures of PM2.5 and its metal constituents from Indian ambient environment to determine limit on PM values. Identified data gaps were: (1) concentrations of PM and its constituents and their relationship with sampling regions, (2) relationship of toxicity of PM with its components.

Keywords: Air, component-specific toxicity, human health risks, particulate matter.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1124
2859 Optimization of Real Time Measured Data Transmission, Given the Amount of Data Transmitted

Authors: Michal Kopcek, Tomas Skulavik, Michal Kebisek, Gabriela Krizanova

Abstract:

The operation of nuclear power plants involves continuous monitoring of the environment in their area. This monitoring is performed using a complex data acquisition system, which collects status information about the system itself and values of many important physical variables e.g. temperature, humidity, dose rate etc. This paper describes a proposal and optimization of communication that takes place in teledosimetric system between the central control server responsible for the data processing and storing and the decentralized measuring stations, which are measuring the physical variables. Analyzes of ongoing communication were performed and consequently the optimization of the system architecture and communication was done.

Keywords: Communication protocol, transmission optimization, data acquisition.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1766
2858 Estimating Reaction Rate Constants with Neural Networks

Authors: Benedek Kovacs, Janos Toth

Abstract:

Solutions are proposed for the central problem of estimating the reaction rate coefficients in homogeneous kinetics. The first is based upon the fact that the right hand side of a kinetic differential equation is linear in the rate constants, whereas the second one uses the technique of neural networks. This second one is discussed deeply and its advantages, disadvantages and conditions of applicability are analyzed in the mirror of the first one. Numerical analysis carried out on practical models using simulated data, and our programs written in Mathematica.

Keywords: Neural networks, parameter estimation, linear regression, kinetic models, reaction rate coefficients.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1931
2857 A 3.125Gb/s Clock and Data Recovery Circuit Using 1/4-Rate Technique

Authors: Il-Do Jeong, Hang-Geun Jeong

Abstract:

This paper describes the design and fabrication of a clock and data recovery circuit (CDR). We propose a new clock and data recovery which is based on a 1/4-rate frequency detector (QRFD). The proposed frequency detector helps reduce the VCO frequency and is thus advantageous for high speed application. The proposed frequency detector can achieve low jitter operation and extend the pull-in range without using the reference clock. The proposed CDR was implemented using a 1/4-rate bang-bang type phase detector (PD) and a ring voltage controlled oscillator (VCO). The CDR circuit has been fabricated in a standard 0.18 CMOS technology. It occupies an active area of 1 x 1 and consumes 90 mW from a single 1.8V supply.

Keywords: Clock and data recovery, 1/4-rate frequency detector, 1/4-rate phase detector.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2870
2856 An Improved Transmission Scheme in Cooperative Communication System

Authors: Seung-Jun Yu, Young-Min Ko, Hyoung-Kyu Song

Abstract:

Recently developed cooperative diversity scheme enables a terminal to get transmit diversity through the support of other terminals. However, most of the introduced cooperative schemes have a common fault of decreased transmission rate because the destination should receive the decodable compositions of symbols from the source and the relay. In order to achieve high data rate, we propose a cooperative scheme that employs hierarchical modulation. This scheme is free from the rate loss and allows seamless cooperative communication.

Keywords: Cooperative communication, hierarchical modulation, high data rate, transmission scheme.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1840
2855 Is Curcumine Effect Comparable to 5- Aminosalicylic Acid or Budesonide on a Rat Model of Ulcerative Colitis Induced by Trinitrobenzene Sulfonic Acid?

Authors: Inas E. Darwish, Alia M. Arab, Tarek A. Azeim, Teshreen M. Zeitoun, Wafaa A. Hewedy, Moemen A. Heiba, Iman S. Emara

Abstract:

Inflammatory bowel disease (IBD) is a chronic relapsing-remitting condition that afflicts millions of people throughout the world and impairs their daily functions and quality of life. Treatment of IBD depends largely on 5-aminosalicylic acid (5- ASA) and corticosteroids. The present study aimed to clarify the effects of 5-aminosalicylic acid, budesonide and currcumin on 90 male albino rats against trinitrobenzene sulfonic acid (TNB) induced colitis. TNB was injected intrarectally to 50 rats. The other 40 rats served as control groups. Both 5-ASA (in a dose of 120 mg/kg) and budesonide (in a dose of 0.1 mg/kg) were administered daily for one week whereas currcumin was injected intraperitonially (in a dose of 30 mg/kg daily) for 14 days after injection of either TNB in the colitis rats (group B) or saline in control groups (group A). The study included estimation of macroscopic score index, histological examination of H&E stained sections of the colonic tissue, biochemical estimation of myeloperoxidase (MPO), nitric oxide (NO), and caspase-3 levels, in addition to studying the effect of tested drugs on colonic motility. It was found that budesonide and curcumin improved mucosal healing, reduced both NO production and caspase- 3 level. They had the best impact on the disturbed colonic motility in TNBS-model of colitis.

Keywords: Colitis, curcumin, nitric oxide.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1631
2854 Forecasting Unemployment Rate in Selected European Countries Using Smoothing Methods

Authors: Ksenija Dumičić, Anita Čeh Časni, Berislav Žmuk

Abstract:

The aim of this paper is to select the most accurate forecasting method for predicting the future values of the unemployment rate in selected European countries. In order to do so, several forecasting techniques adequate for forecasting time series with trend component, were selected, namely: double exponential smoothing (also known as Holt`s method) and Holt-Winters` method which accounts for trend and seasonality. The results of the empirical analysis showed that the optimal model for forecasting unemployment rate in Greece was Holt-Winters` additive method. In the case of Spain, according to MAPE, the optimal model was double exponential smoothing model. Furthermore, for Croatia and Italy the best forecasting model for unemployment rate was Holt-Winters` multiplicative model, whereas in the case of Portugal the best model to forecast unemployment rate was Double exponential smoothing model. Our findings are in line with European Commission unemployment rate estimates.

Keywords: European Union countries, exponential smoothing methods, forecast accuracy unemployment rate.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3718
2853 An Improved STBC Structure and Transmission Scheme for High Rate and Reliability in OFDMA Cooperative Communication

Authors: Hyoung-Muk Lim, Won-Jun Choi, Jae-Seon Yoon, Hyoung-Kyu Song

Abstract:

Space-time block code(STBC) has been studied to get full diversity and full rate in multiple input multiple output(MIMO) system. Achieving full rate is difficult in cooperative communications due to the each user consumes the time slots for transmitting information in cooperation phase. So combining MIMO systems with cooperative communications has been researched for full diversity and full rate. In orthogonal frequency division multiple access (OFDMA) system, it is an alternative way that each user shares their allocated subchannels instead of using the MIMO system to improve the transmission rate. In this paper, a Decode-and-forward (DF) based cooperative communication scheme is proposed. The proposed scheme has improved transmission rate and reliability in multi-path fading channel of the OFDMA up-link condition by modified STBC structure and subchannel sharing.

Keywords: cooperation, improved rate, OFDMA, STBC.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1545
2852 Adaptive Filtering of Heart Rate Signals for an Improved Measure of Cardiac Autonomic Control

Authors: Desmond B. Keenan, Paul Grossman

Abstract:

In order to provide accurate heart rate variability indices of sympathetic and parasympathetic activity, the low frequency and high frequency components of an RR heart rate signal must be adequately separated. This is not always possible by just applying spectral analysis, as power from the high and low frequency components often leak into their adjacent bands. Furthermore, without the respiratory spectra it is not obvious that the low frequency component is not another respiratory component, which can appear in the lower band. This paper describes an adaptive filter, which aids the separation of the low frequency sympathetic and high frequency parasympathetic components from an ECG R-R interval signal, enabling the attainment of more accurate heart rate variability measures. The algorithm is applied to simulated signals and heart rate and respiratory signals acquired from an ambulatory monitor incorporating single lead ECG and inductive plethysmography sensors embedded in a garment. The results show an improvement over standard heart rate variability spectral measurements.

Keywords: Heart rate variability, vagal tone, sympathetic, parasympathetic, spectral analysis, adaptive filter.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1705
2851 A Novel Convergence Accelerator for the LMS Adaptive Algorithm

Authors: Jeng-Shin Sheu, Jenn-Kaie Lain, Tai-Kuo Woo, Jyh-Horng Wen

Abstract:

The least mean square (LMS) algorithmis one of the most well-known algorithms for mobile communication systems due to its implementation simplicity. However, the main limitation is its relatively slow convergence rate. In this paper, a booster using the concept of Markov chains is proposed to speed up the convergence rate of LMS algorithms. The nature of Markov chains makes it possible to exploit the past information in the updating process. Moreover, since the transition matrix has a smaller variance than that of the weight itself by the central limit theorem, the weight transition matrix converges faster than the weight itself. Accordingly, the proposed Markov-chain based booster thus has the ability to track variations in signal characteristics, and meanwhile, it can accelerate the rate of convergence for LMS algorithms. Simulation results show that the LMS algorithm can effectively increase the convergence rate and meantime further approach the Wiener solution, if the Markov-chain based booster is applied. The mean square error is also remarkably reduced, while the convergence rate is improved.

Keywords: LMS, Markov chain, convergence rate, accelerator.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1714
2850 A New H.264-Based Rate Control Algorithm for Stereoscopic Video Coding

Authors: Yi Liao, Wencheng Yang, Gangyi Jiang

Abstract:

According to investigating impact of complexity of stereoscopic frame pairs on stereoscopic video coding and transmission, a new rate control algorithm is presented. The proposed rate control algorithm is performed on three levels: stereoscopic group of pictures (SGOP) level, stereoscopic frame (SFrame) level and frame level. A temporal-spatial frame complexity model is firstly established, in the bits allocation stage, the frame complexity, position significance and reference property between the left and right frames are taken into account. Meanwhile, the target buffer is set according to the frame complexity. Experimental results show that the proposed method can efficiently control the bitrates, and it outperforms the fixed quantization parameter method from the rate distortion perspective, and average PSNR gain between rate-distortion curves (BDPSNR) is 0.21dB.

Keywords: Stereoscopic video coding, rate control, stereoscopic group of pictures, complexity of stereoscopic frame pairs.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1672
2849 Mutation Rate for Evolvable Hardware

Authors: Emanuele Stomeo, Tatiana Kalganova, Cyrille Lambert

Abstract:

Evolvable hardware (EHW) refers to a selfreconfiguration hardware design, where the configuration is under the control of an evolutionary algorithm (EA). A lot of research has been done in this area several different EA have been introduced. Every time a specific EA is chosen for solving a particular problem, all its components, such as population size, initialization, selection mechanism, mutation rate, and genetic operators, should be selected in order to achieve the best results. In the last three decade a lot of research has been carried out in order to identify the best parameters for the EA-s components for different “test-problems". However different researchers propose different solutions. In this paper the behaviour of mutation rate on (1+λ) evolution strategy (ES) for designing logic circuits, which has not been done before, has been deeply analyzed. The mutation rate for an EHW system modifies values of the logic cell inputs, the cell type (for example from AND to NOR) and the circuit output. The behaviour of the mutation has been analyzed based on the number of generations, genotype redundancy and number of logic gates used for the evolved circuits. The experimental results found provide the behaviour of the mutation rate to be used during evolution for the design and optimization of logic circuits. The researches on the best mutation rate during the last 40 years are also summarized.

Keywords: Evolvable hardware, mutation rate, evolutionarycomputation, design of logic circuit.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1457
2848 Phytotoxicity of Daphne Gnidium L. Occurring in Tunisia

Authors: Ladhari A., Omezzine F., Rinez A., Haouala R.

Abstract:

Phytotoxicity of Daphne gnidium L. was evaluated through the effect of incorporating leaves, stems and roots biomass into soil (at 12.5, 25, 50g/Kg) and irrigation by their aqueous extracts (50g/L), on the growth of two crops (Lactuca sativa L. and Raphanus sativus L.) and two weeds (Peaganum harmala L. and Scolymus maculatus L.). Results revealed a perceptible phytotoxic effect which increased with dose and concentration. At the highest dose, roots and leaves residues was the most toxic and caused total inhibition respectively, for lettuce and thistle seedling growth. Irrigation with aqueous extracts of D. gnidium different organs decreased also seedlings length of all test species. Stems extract was more inhibitor on thistle than peganum seedling growth; it induced a significant reduction of 80% and 67%, for, respectively, roots and shoots. Results of the present study suggest that different organs of D. gnidium could be exploited in the management of agro-ecosystems.

Keywords: Biomass, Daphne gnidium L., phytoxicity, seedlinggrowth

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1950
2847 Quantification of Heart Rate Variability: A Measure based on Unique Heart Rates

Authors: V. I. Thajudin Ahamed, P. Dhanasekaran, A. Naseem, N. G. Karthick, T. K. Abdul Jaleel, Paul K.Joseph

Abstract:

It is established that the instantaneous heart rate (HR) of healthy humans keeps on changing. Analysis of heart rate variability (HRV) has become a popular non invasive tool for assessing the activities of autonomic nervous system. Depressed HRV has been found in several disorders, like diabetes mellitus (DM) and coronary artery disease, characterised by autonomic nervous dysfunction. A new technique, which searches for pattern repeatability in a time series, is proposed specifically for the analysis of heart rate data. These set of indices, which are termed as pattern repeatability measure and pattern repeatability ratio are compared with approximate entropy and sample entropy. In our analysis, based on the method developed, it is observed that heart rate variability is significantly different for DM patients, particularly for patients with diabetic foot ulcer.

Keywords: Autonomic nervous system, diabetes mellitus, heart rate variability, pattern identification, sample entropy

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1839
2846 Adsorption of Chromium Ions from Aqueous Solution by Carbon Adsorbent

Authors: S. Heydari, H. Sharififard, M. Nabavinia, H. Kiani, M. Parvizi

Abstract:

Rapid industrialization has led to increased disposal of heavy metals into the environment. Activated carbon adsorption has proven to be an effective process for the removal of trace metal contaminants from aqueous media. This paper was investigated chromium adsorption efficiency by commercial activated carbon. The sorption studied as a function of activated carbon particle size, dose of activated carbon and initial pH of solution. Adsorption tests for the effects of these factors were designed with Taguchi approach. According to the Taguchi parameter design methodology, L9 orthogonal array was used. Analysis of experimental results showed that, the most influential factor was initial pH of solution. The optimum conditions for chromium adsorption by activated carbons were found to be as follows: initial feed pH 6, adsorbent particle size 0.412 mm and activated carbon dose 6 g/l. Under these conditions, nearly %100 of chromium ions was adsorbed by activated carbon after 2 hours.

Keywords: Chromium, Adsorption, Taguchi method, Activated carbon.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2873
2845 Blood Lymphocyte and Neutrophil Response of Cultured Rainbow Trout, Oncorhynchus mykiss, Administered Varying Dosages of an Oral Immunomodulator – ‘Fin-Immune™’

Authors: Duane Barker, John Holliday

Abstract:

In a 10-week (May – August, 2008) Phase I trial, 840, 1+ rainbow trout, Oncorhynchus mykiss, received a commercial oral immunomodulator, Fin Immune™, at four different dosages (0, 10, 20 and 30 mg g-1) to evaluate immune response and growth. The overall objective of was to determine an optimal dosage of this product for rainbow trout that provides enhanced immunity with maximal growth and health. Biweekly blood samples were taken from 10 randomly selected fish in each tank (30 samples per treatment) to evaluate the duration of enhanced immunity conferred by Fin-Immune™. The immunological assessment included serum white blood cell (lymphocyte, neutrophil) densities and blood hematocrit (packed cell volume %). Of these three variables, only lymphocyte density increased significantly among trout fed Fin- Immune™ at 20 and 30 mg g-1 which peaked at week 6. At week 7, all trout were switched to regular feed (lacking Fin-Immune™) and by week 10, lymphocyte levels decreased among all levels but were still greater than at week 0. There was growth impairment at the highest dose of Fin-Immune™ tested (30 mg g-1) which can be associated with a physiological compensatory mechanism due to a dose-specific threshold level. Thus, our main objective of this Phase I study was achieved, the 20 mg g-1 dose of Fin-Immune™ should be the most efficacious (of those we tested) to use for a Phase II disease challenge trial.

Keywords: Blood Lymphocyte, Neutrophil Response of Cultured Rainbow Trout, Oncorhynchus mykiss, Oral Immunomodulator – 'Fin-ImmuneTM'.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1476
2844 Watermark Bit Rate in Diverse Signal Domains

Authors: Nedeljko Cvejic, Tapio Sepp

Abstract:

A study of the obtainable watermark data rate for information hiding algorithms is presented in this paper. As the perceptual entropy for wideband monophonic audio signals is in the range of four to five bits per sample, a significant amount of additional information can be inserted into signal without causing any perceptual distortion. Experimental results showed that transform domain watermark embedding outperforms considerably watermark embedding in time domain and that signal decompositions with a high gain of transform coding, like the wavelet transform, are the most suitable for high data rate information hiding. Keywords?Digital watermarking, information hiding, audio watermarking, watermark data rate.

Keywords: Digital watermarking, information hiding, audio watermarking, watermark data rate.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1581
2843 A Dose Distribution Approach Using Monte Carlo Simulation in Dosimetric Accuracy Calculation for Treating the Lung Tumor

Authors: Md Abdullah Al Mashud, M. Tariquzzaman, M. Jahangir Alam, Tapan Kumar Godder, M. Mahbubur Rahman

Abstract:

This paper presents a Monte Carlo (MC) method-based dose distributions on lung tumor for 6 MV photon beam to improve the dosimetric accuracy for cancer treatment. The polystyrene which is tissue equivalent material to the lung tumor density is used in this research. In the empirical calculations, TRS-398 formalism of IAEA has been used, and the setup was made according to the ICRU recommendations. The research outcomes were compared with the state-of-the-art experimental results. From the experimental results, it is observed that the proposed based approach provides more accurate results and improves the accuracy than the existing approaches. The average %variation between measured and TPS simulated values was obtained 1.337±0.531, which shows a substantial improvement comparing with the state-of-the-art technology.

Keywords: Lung tumor, Monte Carlo, polystyrene, elekta synergy, Monaco Planning System.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1160
2842 PET/CT Patient Dosage Assay

Authors: Gulten Yilmaz, A. Beril Tugrul, Mustafa Demir, Dogan Yasar, Bayram Demir, Bulent Buyuk

Abstract:

A Positron Emission Tomography (PET) is a radioisotope imaging technique that illustrates the organs and the metabolisms of the human body. This technique is based on the simultaneous detection of 511 keV annihilation photons, annihilated as a result of electrons annihilating positrons that radiate from positron-emitting radioisotopes that enter biological active molecules in the body. This study was conducted on ten patients in an effort to conduct patient-related experimental studies. Dosage monitoring for the bladder, which was the organ that received the highest dose during PET applications, was conducted for 24 hours. Assessment based on measuring urination activities after injecting patients was also a part of this study. The MIRD method was used to conduct dosage calculations for results obtained from experimental studies. Results obtained experimentally and theoretically were assessed comparatively.

Keywords: PET/CT, TLD, MIRD, Dose measurement, Patient doses.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1896
2841 CT Medical Images Denoising Based on New Wavelet Thresholding Compared with Curvelet and Contourlet

Authors: Amir Moslemi, Amir Movafeghi, Shahab Moradi

Abstract:

One of the most important challenging factors in medical images is nominated as noise. Image denoising refers to the improvement of a digital medical image that has been infected by Additive White Gaussian Noise (AWGN). The digital medical image or video can be affected by different types of noises. They are impulse noise, Poisson noise and AWGN. Computed tomography (CT) images are subjects to low quality due to the noise. Quality of CT images is dependent on absorbed dose to patients directly in such a way that increase in absorbed radiation, consequently absorbed dose to patients (ADP), enhances the CT images quality. In this manner, noise reduction techniques on purpose of images quality enhancement exposing no excess radiation to patients is one the challenging problems for CT images processing. In this work, noise reduction in CT images was performed using two different directional 2 dimensional (2D) transformations; i.e., Curvelet and Contourlet and Discrete Wavelet Transform (DWT) thresholding methods of BayesShrink and AdaptShrink, compared to each other and we proposed a new threshold in wavelet domain for not only noise reduction but also edge retaining, consequently the proposed method retains the modified coefficients significantly that result good visual quality. Data evaluations were accomplished by using two criterions; namely, peak signal to noise ratio (PSNR) and Structure similarity (Ssim).

Keywords: Computed Tomography (CT), noise reduction, curve-let, contour-let, Signal to Noise Peak-Peak Ratio (PSNR), Structure Similarity (Ssim), Absorbed Dose to Patient (ADP).

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2869
2840 Chose the Right Mutation Rate for Better Evolve Combinational Logic Circuits

Authors: Emanuele Stomeo, Tatiana Kalganova, Cyrille Lambert

Abstract:

Evolvable hardware (EHW) is a developing field that applies evolutionary algorithm (EA) to automatically design circuits, antennas, robot controllers etc. A lot of research has been done in this area and several different EAs have been introduced to tackle numerous problems, as scalability, evolvability etc. However every time a specific EA is chosen for solving a particular task, all its components, such as population size, initialization, selection mechanism, mutation rate, and genetic operators, should be selected in order to achieve the best results. In the last three decade the selection of the right parameters for the EA-s components for solving different “test-problems" has been investigated. In this paper the behaviour of mutation rate for designing logic circuits, which has not been done before, has been deeply analyzed. The mutation rate for an EHW system modifies the number of inputs of each logic gates, the functionality (for example from AND to NOR) and the connectivity between logic gates. The behaviour of the mutation has been analyzed based on the number of generations, genotype redundancy and number of logic gates for the evolved circuits. The experimental results found provide the behaviour of the mutation rate during evolution for the design and optimization of simple logic circuits. The experimental results propose the best mutation rate to be used for designing combinational logic circuits. The research presented is particular important for those who would like to implement a dynamic mutation rate inside the evolutionary algorithm for evolving digital circuits. The researches on the mutation rate during the last 40 years are also summarized.

Keywords: Design of logic circuit, evolutionary computation, evolvable hardware, mutation rate.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1652
2839 An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Authors: P. Suntivarakorn, S. Satmarong, C. Benjapiyaporn, S. Theerakulpisut

Abstract:

This paper was to study the clothes dryer using waste heat from a split type air conditioner with a capacity of 12,648 btu/h. The drying chamber had a minimum cross section area with the size of 0.5 x 1.0 m2. The chamber was constructed by sailcloth and was inside folded with aluminium foil. Then, it was connected to the condensing unit of an air conditioner. The experiment was carried out in two aspects which were the clothes drying with and without auxiliary fan unit. The results showed that the drying rate of clothes in the chamber installed with and without auxiliary fan unit were 2.26 and 1.1 kg/h, respectively. In case of the chamber installed with a auxiliary fan unit, the additional power of 0.011 kWh was consumed and the drying rate was higher than that of clothes drying without auxiliary fan unit. Without auxiliary fan unit installation, no energy was required but there was a portion of hot air leaks away through the punctured holes at the wall of the drying chamber, hence the drying rate was dropped below. The drying rate of clothes drying using waste heat was higher than natural indoor drying and commercial dryer which their drying rate were 0.17 and 1.9 kg/h, respectively. It was noted that the COP of the air conditioner did not change during the operating of clothes drying.

Keywords: Drying Rate, Clothes Dryer, COP, Air Conditioner.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3449
2838 Effect of Gamma Irradiation on the Microhardness of Polymer Blends of Poly (Ethyl Methacrylate)(Pema) and Poly (Ethylene Oxide) (Peo)

Authors: Sanjay Kumar Awasthi, Sunil Kumar Bajpai, Surendra Kumar Pandey, Ajay Utiye

Abstract:

The effect of gamma irradiation on micro-hardness of polymer blends of poly (ethyl methacrylate)(PEMA) and poly (ethylene oxide) (PEO) has been investigated to detect the radiation induced crosslinking. The blend system comprises a noncrystallizable polymer, PEMA and a crystallizable polymer, PEO. On irradiation, the overall hardness of the blend specimens for different dose levels infers occurrence of a crosslinking process. The radiation-induced crosslinking was greater for blends having lower concentration of PEO. However, increase in radiation dose causes softening of blend system due to radiation induced scissioning of the chains

Keywords: Microhardness, Radiation induced crosslinking, Solution cast technique, Vicker's hardness number.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2530
2837 Anti-Inflammatory Activity of Topical Anthocyanins by Complexation and Niosomal Encapsulation

Authors: Aroonsri Priprem, Sucharat Limsitthichaikoon, Suttasinee Thappasarapong

Abstract:

Anthocyanins are natural pigments with effective UV protection but their topical use could be limited due to their physicochemical characteristics. An attempt to overcome such limitations by complexation of 2 major anthocyanin-rich sources, C. ternatea and Z. mays, has potentiated its use as topical antiinflammatory. Cell studies indicate no cytotoxicity of the anthocyanin complex (AC) up to 1 mg/ml tested in HaCaT and human fore head fibroblasts by MTT. Croton oil-induced ear edema in Wistar rats suggests an effective dose of 5 mg/cm2 of AC as a topical anti-inflammatory in comparison to 0.5 mg/cm2 of fluocinolone acetonide. Niosomal encapsulation of the AC significantly prolonged the anti-inflammatory activity particularly at 8 h after topical application (p = 0.0001). The AC was not cytotoxic and its anti-inflammatory and activity was dose-dependent and prolonged by niosomal encapsulation. It has also shown to promote collagen type 1 production in cell culture. Thus, AC could be a potential candidate for topical anti-inflammatory agent from natural resources.

Keywords: Anthocyanin complex, ear edema, inflammation, niosomes, skin.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3095
2836 The Suitability of GPS Receivers Update Rates for Navigation Applications

Authors: Ahmad Abbas Al-Ameen Salih, Nur Liyana Afiqah Che Ahmad Zaini, Amzari Zhahir

Abstract:

Navigation is the processes of monitoring and controlling the movement of an object from one place to another. Currently, Global Positioning System (GPS) is the main navigation system used all over the world for navigation applications. GPS receiver receives signals from at least three satellites to locate and display itself. Displayed positioning information is updated continuously. Update rate is the number of times per second that a display is illuminated. The speed of update is governed by receiver update rate. A higher update rate decreases display lag time and improves distance measurements and tracking especially when moving on a curvy route. The majority of GPS receivers used nowadays are updated every second continuously. This period is considered reasonable for some applications while it is long relatively for high speed applications. In this paper, the suitability and feasibility of GPS receiver with different update rates will be evaluated for various applications according to the level of speed and update rate needed for particular applications.

Keywords: Navigation, Global Positioning System (GPS), GPS receiver, Update rate, Refresh rate, Satellite navigation, High speed GPS receiver.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 7637
2835 Influence of UV Treatment on the Electrooptical Properties of Indium Tin Oxide Films Used in Flexible Displays

Authors: Mariya P. Aleksandrova, Ivelina N. Cholakova, Georgy K. Bodurov, Georgy D. Kolev, Georgy H. Dobrikov

Abstract:

Indium-tin oxide films are deposited by low plasma temperature RF sputtering on highly flexible modification of glycol polyethyleneterephtalate substrates. The produced layers are characterized with transparency over 82 % and sheet resistance of 86.9 Ω/square. The film’s conductivity was further improved by additional UV illumination from light source (365 nm), having power of 250 W. The influence of the UV exposure dose on the structural and electro-optical properties of ITO was investigated. It was established that the optimum time of illumination is 10 minutes and further UV treatment leads to polymer substrates degradation. Structural and bonds type analysis show that at longer treatment carbon atoms release and diffuse into ITO films, which worsen their electrical behavior. For the optimum UV dose the minimum sheet resistance was measured to be 19.2 Ω/square, and the maximum transparency remained almost unchanged – above 82 %.

Keywords: Flexible displays, indium tin oxide, RF sputtering, UV treatment

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2218
2834 Optimal ECG Sampling Frequency for Multiscale Entropy-Based HRV

Authors: Manjit Singh

Abstract:

Multiscale entropy (MSE) is an extensively used index to provide a general understanding of multiple complexity of physiologic mechanism of heart rate variability (HRV) that operates on a wide range of time scales. Accurate selection of electrocardiogram (ECG) sampling frequency is an essential concern for clinically significant HRV quantification; high ECG sampling rate increase memory requirements and processing time, whereas low sampling rate degrade signal quality and results in clinically misinterpreted HRV. In this work, the impact of ECG sampling frequency on MSE based HRV have been quantified. MSE measures are found to be sensitive to ECG sampling frequency and effect of sampling frequency will be a function of time scale.

Keywords: ECG, heart rate variability, HRV, multiscale entropy, sampling frequency.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1309
2833 Wet Sliding Wear and Frictional Behavior of Commercially Available Perspex

Authors: S. Reaz Ahmed, M. S. Kaiser

Abstract:

The tribological behavior of commercially used Perspex was evaluated under dry and wet sliding condition using a pin-on-disc wear tester with different applied loads ranging from 2.5 to 20 N. Experiments were conducted with varying sliding distance from 0.2 km to 4.6 km, wherein the sliding velocity was kept constant, 0.64 ms-1. The results reveal that the weight loss increases with applied load and the sliding distance. The nature of the wear rate was very similar in both the sliding environments in which initially the wear rate increased very rapidly with increasing sliding distance and then progressed to a slower rate. Moreover, the wear rate in wet sliding environment was significantly lower than that under dry sliding condition. The worn surfaces were characterized by optical microscope and SEM. It is found that surface modification has significant effect on sliding wear performance of Perspex.

Keywords: Perspex, wear, friction, SEM.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1153
2832 Some Biochemical Changes Followed Experimental Gastric Ulceration

Authors: A. H. El-Far, R. R. Gindi, H. A. Abd El-Maksoud, Mohamed Ragaa Ragab Hassanien

Abstract:

Gastric ulceration is a discontinuity in gastric mucosa, usually occurs due to imbalance between the gastric mucosal protective factors, that is called gastric mucosal barrier, and the aggressive factors, to which the mucosa is exposed. This study was carried out on sixty male Sprague-Dowely rats (12- 16 weeks old) allocated into two groups. The first control group and the second Gastric lesion group which induced by oral administration of a single daily dose of aspirin at a dose of 300 mg/kg body weight for 7 consecutive-days (6% aspirin solution will be prepared and each rat will be given 5 ml of that solution/kg body weight). Blood is collected 1, 2 and 3 weeks after induction of gastric ulceration. Significant increase in serum copper, nitric oxide, and prostaglandin E2 all over the period of experiment. Significant decrease in erythrocyte superoxide dismutase (t-SOD) activities, serum (calcium, phosphorus, glucose and insulin) levels. Non-significant changes in serum sodium and potassium levels are obtained.

Keywords: Aspirin, Gastric Ulcer, Prostaglandin E2, Superoxide dismutase

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1569