Search results for: M. B. Kime
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2

Search results for: M. B. Kime

2 Laboratory Evaluation of the Flotation Response of a Copper Cobalt Oxide Ore to Gasoil-Rinkalore Mixtures

Authors: M. B. Kime, J. Ntambwe, J. Mwamba

Abstract:

Froth flotation remains to date as one of the most used metallurgical processes for concentrating metal-bearing minerals in ores. Oxide ores are relatively less amenable to froth flotation and require a judicious choice of reagents for the recovery of metals to be optimised. Laboratory batch flotation tests were conducted to determine the effect of two types of gasoil-rinkalore mixtures on the flotation response of a copper cobalt oxide ore sample. The head assay conducted on the initial ore sample showed that it contained about 2.90% of Cu, 0.12% of Co. Upon the flotation test work, the results obtained indicated that the concentrate obtained with use of the mixture gazoil-rinkalore RX yielded 8.24% Cu and 0.22% Co concentrate grades with recoveries of 76.0% Cu and 78.0% Co respectively. But, the concentrate obtained by use of the mixture gazoil-rinkalore RX3 yielded relatively bad results with 5.92% Cu and 0.18% Cu concentrate grades with recoveries of 70.3% Cu and 65.3% Co respectively.

Keywords: Cobalt, copper, froth flotation, Rinkalore RX, Rinkalore RX3, Shangolowe.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2830
1 Conducting Flow Measurement Laboratory Test Work

Authors: M. B. Kime

Abstract:

Mass flow measurement is the basis of most technoeconomic formulations in the chemical industry. This calls for reliable and accurate detection of mass flow. Flow measurement laboratory experiments were conducted using various instruments. These consisted of orifice plates, various sized rotameters, wet gas meter and soap bubble meter. This work was aimed at evaluating appropriate operating conditions and accuracy of the aforementioned devices. The experimental data collected were compared to theoretical predictions from Bernoulli’s equation and calibration curves supplied by the instrument’s manufacturers. The results obtained showed that rotameters were more reliable for measuring high and low flow rates; while soap-bubble meters and wet-gas meters were found to be suitable for measuring low flow rates. The laboratory procedures and findings of the actual work can assist engineering students and professionals in conducting their flow measurement laboratory test work.

Keywords: Flow measurement, orifice plates, rotameters, wet gas meter, soap bubble meter.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4892