Search results for: G. Kabashi
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4

Search results for: G. Kabashi

4 Wind Farm Modeling for Steady State and Dynamic Analysis

Authors: G.Kabashi, K.Kadriu, A.Gashi, S.Kabashi, G, Pula, V.Komoni

Abstract:

This paper focuses on PSS/E modeling of wind farms of Doubly-fed Induction Generator (DFIG) type and their impact on issues of power system operation. Since Wind Turbine Generators (WTG) don-t have the same characteristics as synchronous generators, the appropriate modeling of wind farms is essential for transmission system operators to analyze the best options of transmission grid reinforcements as well as to evaluate the wind power impact on reliability and security of supply. With the high excepted penetration of wind power into the power system a simultaneous loss of Wind Farm generation will put at risk power system security and reliability. Therefore, the main wind grid code requirements concern the fault ride through capability and frequency operation range of wind turbines. In case of grid faults wind turbines have to supply a definite reactive power depending on the instantaneous voltage and to return quickly to normal operation.

Keywords: Power System transients, PSS/E dynamic simulationDouble-fed Induction Generator.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4569
3 Re-Design of Load Shedding Schemes of the Kosovo Power System

Authors: A.Gjukaj, G.Kabashi, G.Pula, N.Avdiu, B.Prebreza

Abstract:

This paper discusses aspects of re-design of loadshedding schemes with respect to actual developments in the Kosovo power system. Load-shedding is a type of emergency control that is designed to ensure system stability by reducing power system load to match the power generation supply. This paper presents a new adaptive load-shedding scheme that provides emergency protection against excess frequency decline, in cases when the Kosovo power system might be disconnected from the regional transmission network. The proposed load-shedding scheme uses the local frequency rate information to adapt the load-shedding pattern to suit the size and location of the occurring disturbance. The proposed scheme is tested in a software simulation on a large scale PSS/E model which represents nine power system areas of Southeast Europe including the Kosovo power system.

Keywords: About Load Shedding, Power System Transient, PSS/E Dynamic Simulation, Under-frequency Protection

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2718
2 Disturbances of the Normal Operation of Kosovo Power System Regarding Atmospheric Discharges

Authors: B. Prebreza, I. Krasniqi, G. Kabashi, G. Pula, N. Avdiu

Abstract:

This paper discusses aspects of outages in the electric transmission network in the Kosovo Power System caused by the atmospheric discharges.

Frequency and location of the atmospheric discharges in Kosovo territory will be provided by a lightning location system ALARM (Automated Lightning Alert and Risk Management) and from the data from the Meteorological Department in Prishtina International Airport. These data will be used to make comparisons with the actual outages registered in the Kosovo Power System from the Kosovo Transmission, systems and market operator (KOSTT) during a specific time period.

The lines with the worst performance determined, regarding the atmospheric discharges, will be choose for further discussions in terms of over voltages caused by the direct or indirect lightning strokes.

Recommendations for protection in terms of insulator coordination and surge arresters will be given at the end and in this stage dynamic simulation will take part.

Keywords: Atmospheric discharges, dynamic simulations, Kosovo Power System, surge arresters.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1783
1 A Study on Removal Characteristics of (Mn2+) from Aqueous Solution by CNT

Authors: Nassereldeen A. Kabashi, Suleyman A. Muyibi. Mohammed E. Saeed., Farhana I. Yahya

Abstract:

It is important to remove manganese from water because of its effects on human and the environment. Human activities are one of the biggest contributors for excessive manganese concentration in the environment. The proposed method to remove manganese in aqueous solution by using adsorption as in carbon nanotubes (CNT) at different parameters: The parameters are CNT dosage, pH, agitation speed and contact time. Different pHs are pH 6.0, pH 6.5, pH 7.0, pH 7.5 and pH 8.0, CNT dosages are 5mg, 6.25mg, 7.5mg, 8.75mg or 10mg, contact time are 10 min, 32.5 min, 55 min, 87.5 min and 120 min while the agitation speeds are 100rpm, 150rpm, 200rpm, 250rpm and 300rpm. The parameters chosen for experiments are based on experimental design done by using Central Composite Design, Design Expert 6.0 with 4 parameters, 5 levels and 2 replications. Based on the results, condition set at pH 7.0, agitation speed of 300 rpm, 7.5mg and contact time 55 minutes gives the highest removal with 75.5%. From ANOVA analysis in Design Expert 6.0, the residual concentration will be very much affected by pH and CNT dosage. Initial manganese concentration is 1.2mg/L while the lowest residual concentration achieved is 0.294mg/L, which almost satisfy DOE Malaysia Standard B requirement. Therefore, further experiments must be done to remove manganese from model water to the required standard (0.2 mg/L) with the initial concentration set to 0.294 mg/L.

Keywords: Adsorption, CNT, DOE, Manganese, Parameters.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1429