Search results for: Fadila Khaldi
3 The Oxidative Stress and the Antioxidant Defense of the Lower Vegetables towards an Environmental Pollution
Authors: Fadila Khaldi, Nedjoud Grara, Houria Berrebbah, Mohamed Réda Djebar
Abstract:
The use of bioindicators plants (lichens, bryophytes and Sphagnum....) in monitoring pollution by heavy metals has been the subject of several works. However, few studies have addressed the impact of specific type-s pollutants (fertilizers, pesticides.) on these organisms. We propose in this work to make the highlighting effect of NPKs (NPK: nitrogen-phosphate-potassium-sulfate (NP2O5K2O) (15,15,15), at concentrations of 10, 20, 30 , 40 and 50mM/L) on the activity of detoxification enzymes (GSH/GST, CAT, APX and MDA) of plant bioindicators (mosses and lichens) after treatment for 3 and 7 days. This study shows the important role of the defense system in the accumulation and tolerance to chemical pollutants through the activation of enzymatic (GST (glutathione-S-transferase, APX (ascorbat peroxidase), CAT (catalase)) and nonenzymatic biomarkers (GSH (glutathione), MDA (malondialdehyde)) against oxidative stress generated by the NPKs.Keywords: NPKs, Bioindicators, lower plants, GSH / GST, CAT, APX and MDA.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 21252 An Experimental Investigation of Heating in Induction Motors
Authors: R. Khaldi, N. Benamrouche, M. Bouheraoua
Abstract:
The ability to predict an accurate temperature distribution requires the knowledge of the losses, the thermal characteristics of the materials, and the cooling conditions, all of which are very difficult to quantify. In this paper, the impact of the effects of iron and copper losses are investigated separately and their effects on the heating in various points of the stator of an induction motor, is highlighted by using two simple tests. In addition, the effect of a defect, such as an open circuit in a phase of the stator, on the heating is also obtained by a no-load test. The squirrel cage induction motor is rated at 2.2 kW; 380 V; 5.2 A; Δ connected; 50 Hz; 1420 rpm and the class of insulation F, has been thermally tested under several load conditions. Several thermocouples were placed in strategic points of the stator.Keywords: induction motor, temperature, heating, losses
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 18491 Fuzzy C-Means Clustering Algorithm for Voltage Stability in Large Power Systems
Authors: Mohamad R. Khaldi, Christine S. Khoury, Guy M. Naim
Abstract:
The steady-state operation of maintaining voltage stability is done by switching various controllers scattered all over the power network. When a contingency occurs, whether forced or unforced, the dispatcher is to alleviate the problem in a minimum time, cost, and effort. Persistent problem may lead to blackout. The dispatcher is to have the appropriate switching of controllers in terms of type, location, and size to remove the contingency and maintain voltage stability. Wrong switching may worsen the problem and that may lead to blackout. This work proposed and used a Fuzzy CMeans Clustering (FCMC) to assist the dispatcher in the decision making. The FCMC is used in the static voltage stability to map instantaneously a contingency to a set of controllers where the types, locations, and amount of switching are induced.Keywords: Fuzzy logic, Power system control, Reactive power control, Voltage control
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1886