Search results for: star covering
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 212

Search results for: star covering

2 Physical Deterioration of Semi-Arid Soils as Affected by Land Use Change in North West of Iran

Authors: Ali Reza Vaezi, Fereshteh Haghshenas

Abstract:

Land use has generally been considered a local environmental issue, but it is becoming a force of global importance. Extensive changes to forests and pastures are being driven by the need to provide food, fiber, and shelter for people in recent decades. Land use is an important factor affecting soil organic carbon accumulation and storage in soils which influence directly on other physicochemical soil properties, soil productivity and soil’s susceptibility to water erosion. The change of pastures to the agricultural lands has been increasing rapidly in most semi-arid regions in Iran. Information on the effect of the land use change in these areas on the deterioration of soil physicochemical properties is limited. Therefore, this study was conducted to investigate the physical deterioration of soil as affected by land use change in semi-arid pastures in north west of Iran. Toward this, seven areas covering both pasture and rainfed lands with different soil textures (clay loam, silty clay loam, sandy clay loam, silt loam, loam, sandy loam and sandy loam) were selected in a semi-arid region in Zanjan, NW Iran. Pasture in the area is covered with poor vegetation and mostly grazed in wet seasons (end of winter and early spring and autumn). Rainfed lands resulting land use change are mostly planted for winter wheat production. In each area, soil samples (0-30 cm depth) were collected from the two land uses (pasture and rainfed land) at three replications. A total of 42 soil samples were taken from the study area. Various soil physical properties consisting of bulk density, total porosity, coarse pores volume, aggregate size, aggregate stability, water-holding capacity and saturated hydraulic conductivity were determined in the soil samples using the laboratory conventional methods. The results showed that the change of pastures to rainfeds is severely deteriorated soil physical properties. However, the variation rate of the physical soil properties is different. The loss of soil physical properties as a result of the land use change was in the following order: 61% water-stable aggregates, 60% aggregate size > 41% macroporosity > 28% bulk density > 22% total porosity > 11% water holding capacity > 5% saturated point. This result reveals that the structural characteristics of soils in this area are the most important soil physical characteristics that are affected by land use change. The deterioration of these soil properties influences negatively the pore size distribution and volume percentage of macroporosity. Effects of land use change on deterioration of soil physical properties were different in various soil textures. The highest mean loss of soil physical properties was found in loam (42%), whereas the lowest value was in silty clay loam (23%). As a consequence, loam is the most vulnerable soil to physical degradation caused by land use change in the pastures. This physical loss of soil is associated with its higher percentage of larger aggregates as well as water-stable aggregates.

Keywords: Pasture, soil physical properties, soil structural characteristics, soil texture.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 97
1 Thermal Securing of Electrical Contacts inside Oil Power Transformers

Authors: Ioan Rusu

Abstract:

In the operation of power transformers of 110 kV/MV from substations, these are traveled by fault current resulting from MV line damage. Defect electrical contacts are heated when they are travelled from fault currents. In the case of high temperatures when 135 °C is reached, the electrical insulating oil in the vicinity of the electrical faults comes into contact with these contacts releases gases, and activates the electrical protection. To avoid auto-flammability of electro-insulating oil, we designed a security system thermal of electrical contact defects by pouring fire-resistant polyurethane foam, mastic or mortar fire inside a cardboard electro-insulating cylinder. From practical experience, in the exploitation of power transformers of 110 kV/MT in oil electro-insulating were recorded some passing disconnecting commanded by the gas protection at internal defects. In normal operation and in the optimal load, nominal currents do not require thermal secure contacts inside electrical transformers, contacts are made at the fabrication according to the projects or to repair by solder. In the case of external short circuits close to the substation, the contacts inside electrical transformers, even if they are well made in sizes of Rcontact = 10‑6 Ω, are subjected to short-circuit currents of the order of 10 kA-20 kA which lead to the dissipation of some significant second-order electric powers, 100 W-400 W, on contact. At some internal or external factors which action on electrical contacts, including electrodynamic efforts at short-circuits, these factors could be degraded over time to values in the range of 10-4 Ω to 10-5 Ω and if the action time of protection is great, on the order of seconds, power dissipation on electrical contacts achieve high values of 1,0 kW to 40,0 kW. This power leads to strong local heating, hundreds of degrees Celsius and can initiate self-ignition and burning oil in the vicinity of electro-insulating contacts with action the gas relay. Degradation of electrical contacts inside power transformers may not be limited for the duration of their operation. In order to avoid oil burn with gas release near electrical contacts, at short-circuit currents 10 kA-20 kA, we have outlined the following solutions: covering electrical contacts in fireproof materials that would avoid direct burn oil at short circuit and transmission of heat from electrical contact along the conductors with heat dissipation gradually over time, in a large volume of cooling. Flame retardant materials are: polyurethane foam, mastic, cement (concrete). In the normal condition of operation of transformer, insulating of conductors coils is with paper and insulating oil. Ignition points of its two components respectively are approximated: 135 °C heat for oil and 200 0C for paper. In the case of a faulty electrical contact, about 10-3 Ω, at short-circuit; the temperature can reach for a short time, a value of 300 °C-400 °C, which ignite the paper and also the oil. By burning oil, there are local gases that disconnect the power transformer. Securing thermal electrical contacts inside the transformer, in cardboard tube with polyurethane foams, mastik or cement, ensures avoiding gas release and also gas protection working.

Keywords: Power transformer, oil insulatation, electric contacts, gases, gas relay.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 648