3 Electrical Analysis of Corn Oil as an Alternative to Mineral Oil in Power Transformers

Authors: C. Kocatepe, E. Taslak, C. F. Kumru, O. Arıkan

Abstract:

In insulation and cooling of power transformers various liquids are used. Mineral oils have wide availability and low cost. However, they have a poor biodegradability potential and lower fire point in comparison with other insulating liquids. Use of a liquid having high biodegradability is important due to environmental consideration. This paper investigates edible corn oil as an alternative to mineral oil. Various properties of mineral and corn oil like breakdown voltage, dissipation factor, relative dielectric constant, power loss and resistivity were measured according to different standards.

Keywords: resistivity, power loss, breakdown voltage, corn oil, dissipation factor, mineral oil, relative dielectric constant

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2751
2 An Investigation on Electric Field Distribution around 380 kV Transmission Line for Various Pylon Models

Authors: C. Kocatepe, C. F. Kumru, O. Arikan

Abstract:

In this study, electric field distribution analyses for three pylon models are carried out by a Finite Element Method (FEM) based software. Analyses are performed in both stationary and time domains to observe instantaneous values along with the effective ones. Considering the results of the study, different line geometries is considerably affecting the magnitude and distribution of electric field although the line voltages are the same. Furthermore, it is observed that maximum values of instantaneous electric field obtained in time domain analysis are quite higher than the effective ones in stationary mode. In consequence, electric field distribution analyses should be individually made for each different line model and the limit exposure values or distances to residential buildings should be defined according to the results obtained.

Keywords: Electric Field, energy transmission line, pylon, finite element method

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2306
1 An Investigation on Vegetable Oils as Potential Insulating Liquid

Authors: C. Kocatepe, E. Taslak, C. F. Kumru, O. Arıkan

Abstract:

While choosing insulating oil, characteristic features such as thermal cooling, endurance, efficiency and being environment-friendly should be considered. Mineral oils are referred as petroleum-based oil. In this study, vegetable oils investigated as an alternative insulating liquid to mineral oil. Dissipation factor, breakdown voltage, relative dielectric constant and resistivity changes with the frequency and voltage of mineral, rapeseed and nut oils were measured. Experimental studies were performed according to ASTM D924 and IEC 60156 standards.

Keywords: vegetable oils, breakdown voltage, mineral oil, dielectric dissipation factor

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2117

Abstracts

2 Electrical Analysis of Corn Oil as an Alternative to Mineral Oil in Power Transformers

Authors: E. Taslak, C. F. Kumru, O. Arıkan, C. Kocatepe

Abstract:

In insulation and cooling of power transformers various liquids are used. Mineral oils have wide availability and low cost. However, they have a poor biodegradability potential and lower fire point in comparison with other insulating liquids. Use of a liquid having high biodegradability is important due to environmental consideration. This paper investigates edible corn oil as an alternative to mineral oil. Various properties of mineral and corn oil like breakdown voltage, dissipation factor, relative dielectric constant, power loss and resistivity were measured according to different standards.

Keywords: resistivity, power loss, breakdown voltage, corn oil, dissipation factor, mineral oil, relative dielectric constant

Procedia PDF Downloads 416
1 An Investigation on Electric Field Distribution around 380 kV Transmission Line for Various Pylon Models

Authors: C. Kocatepe, C. F. Kumru, O. Arikan

Abstract:

In this study, electric field distribution analyses for three pylon models are carried out by a Finite Element Method (FEM) based software. Analyses are performed in both stationary and time domains to observe instantaneous values along with the effective ones. Considering the results of the study, different line geometries is considerably affecting the magnitude and distribution of electric field although the line voltages are the same. Furthermore, it is observed that maximum values of instantaneous electric field obtained in time domain analysis are quite higher than the effective ones in stationary mode. In consequence, electric field distribution analyses should be individually made for each different line model and the limit exposure values or distances to residential buildings should be defined according to the results obtained.

Keywords: Finite Element Method, Electric Field, energy transmission line, pylon

Procedia PDF Downloads 561