4 Determination and Preconcentration of Iron (II) in Aqueous Solution with Amberlite XAD-4 Functionalized with 1-amino-2-naphthole by Flame Atomic Absorption Spectrometry

Authors: Homayon Ahmad Panahi, Mahshid Nikpour Nezhati, Faranak Mahmoudi, Elham Moniri, Meghdad Karimi

Abstract:

A new chelating resin is prepared by coupling Amberlite XAD-4 with 1-amino-2-naphthole through an azo spacer. The resulting sorbent has been characterized by FT-IR, elemental analysis and thermogravimetric analysis (TGA) and studied for preconcentrating of Fe (II) using flame atomic absorption spectrometry (FAAS) for metal monitoring. The optimum pH value for sorption of the iron ions was 6.5. The resin was subjected to evaluation through batch binding of mentioned metal ion. Quantitative desorption occurs instantaneously with 0.5 M HNO3. The sorption capacity was found 4.1 mmol.g-1 of resin for Fe (II) in the aqueous solution. The chelating resin can be reused for 10 cycles of sorption-desorption without any significant change in sorption capacity. A recovery of 97% was obtained the metal ions with 0.5 M HNO3 as eluting agent. The method was applied for metal ions determination from industrial waste water sample.

Keywords: Amberlite XAD-4, Iron (II), Flame atomic absorption, Chelator, 1-amino-2- naphthole

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF
3 Amberlite XAD-4 Functionalized with 1-amino-2-naphthole for Determination and Preconcentration of Copper (II) in Aqueous Solution by Flame Atomic Absorption Spectrometry

Authors: Elham Moniri, Homayon Ahmad Panahi, Mahshid Nikpour Nezhati, Faranak Mahmoudi, Meghdad Karimi

Abstract:

A new chelating resin is prepared by coupling Amberlite XAD-4 with 1-amino-2-naphthole through an azo spacer. The resulting sorbent has been characterized by FT-IR, elemental analysis and thermogravimetric analysis (TGA) and studied for preconcentrating of Cu (II) using flame atomic absorption spectrometry (FAAS) for metal monitoring. The optimum pH value for sorption of the copper ions was 6.5. The resin was subjected to evaluation through batch binding of mentioned metal ion. Quantitative desorption occurs instantaneously with 0.5 M HNO3. The sorption capacity was found 4.8 mmol.g-1 of resin for Cu (II) in the aqueous solution. The chelating resin can be reused for 10 cycles of sorption-desorption without any significant change in sorption capacity. A recovery of 99% was obtained the metal ions with 0.5 M HNO3 as eluting agent. The method was applied for metal ions determination from industrial waste water sample.

Keywords: Amberlite XAD-4; Copper (II); Flame atomicabsorption; Chelator; 1-amino-2- naphthole

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF
2 Separation of Vitamin B2 and B12 byImpregnate HPTLC Plates with Boric Acid

Authors: Homayon Ahmad Panahi, Hossein Sid Kalal, Atyeh Rahimi

Abstract:

A high performance thin layer chromatography system (HPTLC) for the separation of vitamin B2 and B12 has been developed. The separation was successfully using a solvent system of methanol, water, ammonia 7.3.1 (V/V) as mobile phase on HPTLC plates impregnated with boric acid. The effect of other mobile phases on the separation of vitamins was also examined. The method is based on different behavior of investigated compounds in impregnated TLC plates with different amount of boric acid. The Rf values of vitamin B2 and B12 are considered on non impregnated and impregnated silica gel HPTLC plate with boric acid. The effect of boric acid in the mobile phase and on HPTLC plates on the RF values of the vitamins has also been studied.

Keywords: High performance thin layer chromatography, HPTLC, Vitamin B2, Vitamin B12, Separation.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF
1 Effect of Boric Acid on a-Hydroxy Acids Compounds in Thin Layer Chromatography

Authors: Elham Moniri, Homayon Ahmad Panahi, Ahmad Izadi, Mohamad Mehdi Parvin, Atyeh Rahimi

Abstract:

In this investigation Salicylic acid, Sulfosalicylic acid and Acetyl salicylic acid were chosen as a sample for thin layer chromatography (TLC) on silica gel plates. Bicarbonate buffer at different pH containing different amounts of boric acid was applied as mobile phase. Specific interaction of these substances with boric acid has effect on Rf in thin layer chromatography. Regular and similar trend was observed in variations of Rf for mentioned compounds in TLC by altering of percentages of boric acid in mobile phase in pH range of 8-10. Also effect of organic solvent, mixture of water/ organic solvent and organic solvent containing boric acid as mobile phase was studied.

Keywords: Thin layer chromatography (TLC), Aspirin, Salicylic acid, Sulfosalycylic acid, Boric acid.