Search results for: urine sample testing
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 8594

Search results for: urine sample testing

8594 An Automated Magnetic Dispersive Solid-Phase Extraction Method for Detection of Cocaine in Human Urine

Authors: Feiyu Yang, Chunfang Ni, Rong Wang, Yun Zou, Wenbin Liu, Chenggong Zhang, Fenjin Sun, Chun Wang

Abstract:

Cocaine is the most frequently used illegal drug globally, with the global annual prevalence of cocaine used ranging from 0.3% to 0.4 % of the adult population aged 15–64 years. Growing consumption trend of abused cocaine and drug crimes are a great concern, therefore urine sample testing has become an important noninvasive sampling whereas cocaine and its metabolites (COCs) are usually present in high concentrations and relatively long detection windows. However, direct analysis of urine samples is not feasible because urine complex medium often causes low sensitivity and selectivity of the determination. On the other hand, presence of low doses of analytes in urine makes an extraction and pretreatment step important before determination. Especially, in gathered taking drug cases, the pretreatment step becomes more tedious and time-consuming. So developing a sensitive, rapid and high-throughput method for detection of COCs in human body is indispensable for law enforcement officers, treatment specialists and health officials. In this work, a new automated magnetic dispersive solid-phase extraction (MDSPE) sampling method followed by high performance liquid chromatography-mass spectrometry (HPLC-MS) was developed for quantitative enrichment of COCs from human urine, using prepared magnetic nanoparticles as absorbants. The nanoparticles were prepared by silanizing magnetic Fe3O4 nanoparticles and modifying them with divinyl benzene and vinyl pyrrolidone, which possesses the ability for specific adsorption of COCs. And this kind of magnetic particle facilitated the pretreatment steps by electromagnetically controlled extraction to achieve full automation. The proposed device significantly improved the sampling preparation efficiency with 32 samples in one batch within 40mins. Optimization of the preparation procedure for the magnetic nanoparticles was explored and the performances of magnetic nanoparticles were characterized by scanning electron microscopy, vibrating sample magnetometer and infrared spectra measurements. Several analytical experimental parameters were studied, including amount of particles, adsorption time, elution solvent, extraction and desorption kinetics, and the verification of the proposed method was accomplished. The limits of detection for the cocaine and cocaine metabolites were 0.09-1.1 ng·mL-1 with recoveries ranging from 75.1 to 105.7%. Compared to traditional sampling method, this method is time-saving and environmentally friendly. It was confirmed that the proposed automated method was a kind of highly effective way for the trace cocaine and cocaine metabolites analyses in human urine.

Keywords: automatic magnetic dispersive solid-phase extraction, cocaine detection, magnetic nanoparticles, urine sample testing

Procedia PDF Downloads 165
8593 Study on the Relative Factors of Introducing Table Vinegar in Reducing Urinary Tract Infection in Patients with Long-Term Indwelling Catheter

Authors: Yu-Ju Hsieh, Lin-Hung Lin, Wen-Hui Chang

Abstract:

This study was designed as an interventional research and intended to validate whether the introduction of drinking vinegar every day can reduce and even prevent urinary tract infection in Taiwan home stayed disabilities who using indwelling catheter. The data was collected from the subjects who have received home care case at northern Taiwan, according to the questionnaire and a medical records retroactive methodology, the subjects were informed and consent to drink 15ml of table vinegar in a daily diet, and through routine urine testing and culture study. Home care nurses would assist collecting urine at the point of before and after a meal from total 35 studied subjects per month, and total collected 4 times for testing. The results showed that when the average age of study subjects was 65.46 years and catheter indwelling time was 15 years, drinking table vinegar could inhibit the activity of E. coli O157: H7 and reduce its breeding. Before drinking table vinegar daily, the subjects’ urine pH value was 7.0-8.0, and the average was 7.5, and the urine PH value dropped to 6.5 after drinking table vinegar for a month. There were two purple urine cases whose urine were changed from purple to normal color after two weeks of drinking, and the protein and bacteria values of urine gradually improved. Urine smell unpleasant before attending to this study, and the symptom improved significantly only after 1 week, and the urine smell returned to normal ammonia and became clean after 1 month later. None of these subjects received treatment in a hospital due to urinary tract infection, and there were no signs of bleeding in all cases during this study. The subjects of this study are chronic patients with a long-term bedridden catheterization; drinking cranberry juice is an economic burden for them, and also highly prohibited for diabetes patients. By adapting to use cheaper table vinegar to acidified urine and improve its smell and ease Purple Urine Syndrome, to furthermore, proven urinary tract infection, it can also to reduce the financial burden on families, the cost of social resources and the rate of re-admission.

Keywords: table vinegar, urinary tract infection, disability patients, long-term indwelling catheter

Procedia PDF Downloads 230
8592 Cross Reactivity of Risperidone in Fentanyl Point of Care Devices

Authors: Barry D. Kyle, Jessica Boyd, Robin Pickersgill, Nicole Squires, Cynthia Balion

Abstract:

Background-Aim: Fentanyl is a highly-potent synthetic μ-opioid receptor agonist used for exceptional pain management. Its main metabolite, norfentanyl, is typically present in urine at significantly high concentrations (i.e. ~20%) representing an effective targeting molecule for immunoassay detection. Here, we evaluated the NCSTM One Step Fentanyl Test Device© and the BTNX Rapid ResponseTM Single Drug Test Strip© point of care (POC) test strips targeting norfentanyl (20 ng/ml) and fentanyl (100 ng/ml) molecules for potential risperidone interference. Methods: POC tests calibrated against norfentanyl (20 ng/ml) used [immunochromatographic] lateral flow devices to provide qualitative results within five minutes of urine sample contact. Results were recorded as negative if lines appeared in the test and control regions according to manufacturer’s instructions. Positive results were recorded if no line appeared in the test region (i.e., control line only visible). Pooled patient urine (n=20), that screened negative for drugs of abuse (using NCS One Step Multi-Line Screen) and fentanyl (using BTNX Rapid Response Strip) was used for spiking studies. Urine was spiked with risperidone alone and with combinations of fentanyl, norfentanyl and/or risperidone to evaluate cross-reactivity in each test device. Results: A positive screen result was obtained when 8,000 ng/mL of risperidone was spiked into drug free urine using the NCS test device. Positive screen results were also obtained in spiked urine samples containing fentanyl and norfentanyl combinations below the cut-off concentrations when 4000 ng/mL risperidone was present using the NCS testing device. There were no screen positive test results using the BTNX test strip with up to 8,000 ng/mL alone or in combination with concentrations of fentanyl and norfentanyl below the cut-off. Both devices screened positive when either fentanyl or norfentanyl exceeded the cut-off threshold in the absence and presence of risperidone. Conclusion: We report that urine samples containing risperidone may give a false positive result using the NCS One Step Fentanyl Test Device.

Keywords: fentanyl, interferences, point of care test, Risperidone

Procedia PDF Downloads 225
8591 The Use of Urine Cytology in an Australian Regional Hospital Compared to International Guidelines

Authors: Jake Tempo, Stephen Brough

Abstract:

Introduction and Objectives: Urine cytology has a role in the diagnosis of urothelial cancer when used alongside cystoscopy and imaging, according to the European Association of Urology guidelines. It also has a role in the surveillance post-treatment of urothelial carcinoma. Collecting and analysing urine cytology is costly and time-consuming. We investigated the use of urine cytology in an Australian regional hospital to determine whether clinicians are following international guidelines. Materials and Methods: We analysed all urine cytology requests performed in an Australian regional hospital between 1st January 2017 and 31st December 2018. We reviewed the indication for urine cytology and the patients’ case notes to determine whether urine cytology changed management. Results: During the two-year study period, 153 patients had urine cytology analysed for a variety of indications. In no cases did cytology change the outcome of patient management significantly. In total, 69 of 153 (41%) urine cytology requests were not supported by urological society guidelines. Fifty requests were for haematuria, and twenty requests were for urothelial cancer surveillance. Seven were analysed for follow-up from previous urological investigations. Nine samples were sent for ureteric obstruction of unknown origin. Conclusion: Urine cytology, even when positive, did not significantly change management for the investigation of potential urothelial cancer, and therefore, its use as a diagnostic tool for this purpose should be reconsidered. Many cytology tests are expensive, unnecessary, and not supported by urological society guidelines.

Keywords: cytology, bladder cancer, urine, urothelial carcinoma

Procedia PDF Downloads 58
8590 Growth of Struvite Crystals in Synthetic Urine Using Magnesium Nitrate

Authors: Reneiloe Seodigeng, John Kabuba, Hilary Rutto, Tumisang Seodigeng

Abstract:

Urine diversion toilets have become popular as a means of solving the challenges in sanitation. As a result, the source-separated urine must be adequately treated so that it can be disposed of safely and valuable struvite can be extracted for use as fertilizer. In this study, synthetic urine was prepared, and struvite crystallisation experiments carried out using magnesium nitrate. The effect of residence time on crystal growth was studied. At residence time of 10, 30 and 60 minutes, mean particle sizes were 17, 34 and 53 µm showing that with higher residence times, larger crystal sizes can be achieved. SEM analysis of the crystal showed that the resultant crystals had the typical morphology of struvite crystals.

Keywords: struvite, magnesium nitrate, crystallisation, urine treatment

Procedia PDF Downloads 129
8589 Diagnostic Evaluation of Urinary Angiogenin (ANG) and Clusterin (CLU) as Biomarker for Bladder Cancer

Authors: Marwa I. Shabayek, Ola A. Said, Hanan A. Attaia, Heba A. Awida

Abstract:

Bladder carcinoma is an important worldwide health problem. Both cystoscopy and urine cytology used in detecting bladder cancer suffer from drawbacks where cystoscopy is an invasive method and urine cytology shows low sensitivity in low grade tumors. This study validates easier and less time-consuming techniques to evaluate the value of combined use of angiogenin and clusterin in comparison and combination with voided urine cytology in the detection of bladder cancer patients. This study includes malignant (bladder cancer patients, n= 50), benign (n=20), and healthy (n=20) groups. The studied groups were subjected to cystoscopic examination, detection of bilharzial antibodies, urine cytology, and estimation of urinary angiogenin and clusterin by ELISA. The overall sensitivity and specifcity were 66% and 75% for angiogenin, 70% and 82.5% for clusterin and 46% and 80% for voided urine cytology. Combined sensitivity of angiogenin and clusterin with urine cytology increased from 82 to 88%.

Keywords: angiogenin, bladder cancer, clusterin, cytology

Procedia PDF Downloads 263
8588 Studies on the Feasibility of Cow’s Urine as Non-Conventional Energy Sources

Authors: Raj Kumar Rajak, Bharat Mishra

Abstract:

Bio-batteries represent an entirely new long-term, reasonable, reachable, and eco-friendly approach to generation of sustainable energy. In the present experimental work, we have studied the effect of the generation of power by bio-battery using different electrode pairs. The tests show that it is possible to generate electricity using cow’s urine as an electrolyte. C-Mg electrode pair shows maximum Voltage and Short Circuit Current (SCC), while C-Zn electrode pair shows less Open Circuit Voltage (OCV) and SCC. By the studies of cow urine and different electrodes, it is found that C-Zn electrode battery is more economical. The cow urine battery with C-Zn electrode provides maximum power (707.4 mW) and durability (up to 145 h). This result shows that the bio-batteries have the potency to full fill the need of electricity demand for lower energy equipment.

Keywords: bio-batteries, cow's urine, electrodes, non-conventional

Procedia PDF Downloads 158
8587 Prevalence of ESBL E. coli Susceptibility to Oral Antibiotics in Outpatient Urine Culture: Multicentric, Analysis of Three Years Data (2019-2021)

Authors: Mazoun Nasser Rashid Al Kharusi, Nada Al Siyabi

Abstract:

Objectives: The main aim of this study is to Find the rate of susceptibility of ESBL E. coli causing UTI to oral antibiotics. Secondary objectives: Prevalence of ESBL E. coli from community urine samples, identify the best empirical oral antibiotics with the least resistance rate for UTI and identify alternative oral antibiotics for testing and utilization. Methods: This study is a retrospective descriptive study of the last three years in five major hospitals in Oman (Khowla Hospital, AN’Nahdha Hospital, Rustaq Hospital, Nizwa Hospital, and Ibri Hospital) equipped with a microbiologist. Inclusion criteria include all eligible outpatient urine culture isolates, excluding isolates from admitted patients with hospital-acquired urinary tract infections. Data was collected through the MOH database. The MOH hospitals are using different types of testing, automated methods like Vitek2 and manual methods. Vitek2 machine uses the principle of the fluorogenic method for organism identification and a turbidimetric method for susceptibility testing. The manual method is done by double disc diffusion for identifying ESBL and the disc diffusion method is for antibiotic susceptibility. All laboratories follow the clinical laboratory science institute (CLSI) guidelines. Analysis was done by SPSS statistical package. Results: Total urine cultures were (23048). E. coli grew in (11637) 49.6% of the urine, whereas (2199) 18.8% of those were confirmed as ESBL. As expected, the resistance rate to amoxicillin and cefuroxime is 100%. Moreover, the susceptibility of those ESBL-producing E. coli to nitrofurantoin, trimethoprim+sulfamethoxazole, ciprofloxacin and amoxicillin-clavulanate is progressing over the years; however, still low. ESBL E. coli was predominating in the female gender and those aged 66-74 years old throughout all the years. Other oral antibiotic options need to be explored and tested so that we add to the pool of oral antibiotics for ESBL E. coli causing UTI in the community. Conclusion: High rate of ESBL E. coli in urine from the community. The high resistance rates to oral antibiotics highlight the need for alternative treatment options for UTIs caused by these bacteria. Further research is needed to identify new and effective treatments for UTIs caused by ESBL-E. Coli.

Keywords: UTI, ESBL, oral antibiotics, E. coli, susceptibility

Procedia PDF Downloads 48
8586 Characterization of Martensitic Stainless Steel Japanese Grade AISI 420A

Authors: T. Z. Butt, T. A. Tabish, K. Anjum, H. Hafeez

Abstract:

A study of martensitic stainless steel surgical grade AISI 420A produced in Japan was carried out in this research work. The sample was already annealed at about 898˚C. The sample were subjected to chemical analysis, hardness, tensile and metallographic tests. These tests were performed on as received annealed and heat treated samples. In the annealed condition the sample showed 0HRC. However, on tensile testing, in annealed condition the sample showed maximum elongation. The heat treatment is carried out in vacuum furnace within temperature range 980-1035°C. The quenching of samples was carried out using liquid nitrogen. After hardening, the samples were subjected to tempering, which was carried out in vacuum tempering furnace at a temperature of 220˚C. The hardened samples were subjected to hardness and tensile testing. In hardness testing, the samples showed maximum hardness values. In tensile testing the sample showed minimum elongation. The sample in annealed state showed coarse plates of martensite structure. Therefore, the studied steels can be used as biomaterials.

Keywords: biomaterials, martensitic steel, microsrtucture, tensile testing, hardening, tempering, bioinstrumentation

Procedia PDF Downloads 239
8585 Perceptions of Farmers against Liquid Fertilizer Benefits of Beef Cattle Urine

Authors: Sitti Nurani Sirajuddin, Ikrar Moh. Saleh, Kasmiyati Kasim

Abstract:

The aim of this study was to know the perception of livestock farmers on the use of liquid organic fertilizer from urine of cattle at Sinjai Regency, South Sulawesi Province. The choice of location for a farmer group manufactures and markets liquid organic fertilizer from cattle urine. This research was conducted in May to July 2013.The population were all livestock farmers who use organic liquid fertilizer from cattle urine samples while livestock farmers who are directly involved in the manufacture of liquid organic fertilizer totaled 42 people. Data were collected through observation and interview. Data were analyzed descriptively. The results showed that the perception of livestock farmers of using liquid organic fertilizer from cattle urine provide additional revenue benefits, cost minimization farming, reducing environmental pollution which not contrary to the customs.

Keywords: liquid organic fertilizer, perceptions, farmers, beef cattle

Procedia PDF Downloads 432
8584 Protective Effect of Cow Urine against Chlorpyrifos Induced-Genotoxicity and Neurotoxicity in Albino Rats

Authors: Shelly Sharma, Pooja Chadha

Abstract:

Humans are exposed to pesticides and insecticides either directly or indirectly. Exposure to these pesticides may lead to acute toxicity to mammals and non-target organisms. Chlorpyrifos (CPF) is a broad spectrum organophosphate pesticide widely used in various countries of the world. The aim of the present study was to assess the toxicity associated with chlorpyrifos exposure and possible mitigating effect of cow urine against genotoxic and toxic effects in rat brain induced by chlorpyrifos. For this purpose LD50 was determined and rats were orally administered with 1/8th of LD50 (19mg/kg b.wt). Brain samples were taken after 24hrs, 48hrs and 72hrs of treatment. A significant increase in the % tail DNA was observed along with the increase in MDA levels of brain tissues in chlorpyrifos treated groups as compared to control. Cow urine treated groups show decrease in DNA damage and MDA levels as compared to CPF treated group. The study indicates that cow urine has ameliorative potential against neurotoxicity and genotoxicity induced by CPF. Cow urine is considered rich in vitamin A, E and volatile fatty acids which provide antioxidant potential to it. Thus, it can be used as a genoprotective agent.

Keywords: comet assay, brain, cow urine, genotoxicity, toxicity

Procedia PDF Downloads 351
8583 Simultaneous Determination of p-Phenylenediamine, N-Acetyl-p-phenylenediamine and N,N-Diacetyl-p-phenylenediamine in Human Urine by LC-MS/MS

Authors: Khaled M. Mohamed

Abstract:

Background: P-Phenylenediamine (PPD) is used in the manufacture of hair dyes and skin decoration. In some developing countries, suicidal, homicidal and accidental cases by PPD were recorded. In this work, a sensitive LC-MS/MS method for determination of PPD and its metabolites N-acetyl-p-phenylenediamine (MAPPD) and N,N-diacetyl-p-phenylenediamine (DAPPD) in human urine has been developed and validated. Methods: PPD, MAPPD and DAPPD were extracted from urine by methylene chloride at alkaline pH. Acetanilide was used as internal standard (IS). The analytes and IS were separated on an Eclipse XDB- C18 column (150 X 4.6 mm, 5 µm) using a mobile phase of acetonitrile-1% formic acid in gradient elution. Detection was performed by LC-MS/MS using electrospray positive ionization under multiple reaction-monitoring mode. The transition ions m/z 109 → 92, m/z 151 → 92, m/z 193 → 92, and m/z 136 → 77 were selected for the quantification of PPD, MAPPD, DAPPD, and IS, respectively. Results: Calibration curves were linear in the range 10–2000 ng/mL for all analytes. The mean recoveries for PPD, MAPPD and DAPPD were 57.62, 74.19 and 50.99%, respectively. Intra-assay and inter-assay imprecisions were within 1.58–9.52% and 5.43–9.45% respectively for PPD, MAPPD and DAPPD. Inter-assay accuracies were within -7.43 and 7.36 for all compounds. PPD, MAPPD and DAPPD were stable in urine at –20 degrees for 24 hours. Conclusions: The method was successfully applied to the analysis of PPD, MAPPD and DAPPD in urine samples collected from suicidal cases.

Keywords: p-Phenylenediamine, metabolites, urine, LC-MS/MS, validation

Procedia PDF Downloads 322
8582 Customized Cow’s Urine Battery Using MnO2 Depolarizer

Authors: Raj Kumar Rajak, Bharat Mishra

Abstract:

Bio-battery represents an entirely new long term, reasonable, reachable and ecofriendly approach to production of sustainable energy. Types of batteries have been developed using MnO2 in various ways. MnO2 is suitable with physical, chemical, electrochemical, and catalytic properties, serving as an effective cathodic depolarizer and may be considered as being the life blood of the battery systems. In the present experimental work, we have studied the effect of generation of power by bio-battery using different concentrations of MnO2. The tests show that it is possible to generate electricity using cow’s urine as an electrolyte. After ascertaining the optimum concentration of MnO2, various battery parameters and performance indicates that cow urine solely produces power of 695 mW, while a combination with MnO2 (40%) enhances power of bio-battery, i.e. 1377 mW. On adding more and more MnO2 to the electrolyte, the power suppressed because inflation of internal resistance. The analysis of the data produced from experiment shows that MnO2 is quite suitable to energize the bio-battery.

Keywords: bio-batteries, cow’s urine, manganese dioxide, non-conventional

Procedia PDF Downloads 223
8581 The Role of Chemokine Family, CXCL-10 Urine as a Marker Diagnosis of Active Lung Tuberculosis in HIV/AIDS Patients

Authors: Dwitya Elvira, Raveinal Masri, Rohayat Bilmahdi

Abstract:

Human Immunodeficiency Virus (HIV) pandemic increased significantly worldwide. The rise in cases of HIV/AIDS was also followed by an increase in the incidence of opportunistic infection, with tuberculosis being the most opportunistic infection found in HIV/AIDS and the main cause of mortality in HIV/AIDS patients. Diagnosis of tuberculosis in HIV/AIDS patients is often difficult because of the uncommon symptom in HIV/AIDS patients compared to those without the disease. Thus, diagnostic tools are required that are more effective and efficient to diagnose tuberculosis in HIV/AIDS. CXCL-10/IP-10 is a chemokine that binds to the CXCR3 receptor found in HIV/AIDS patients with a weakened immune system. Tuberculosis infection in HIV/AIDS activates chemokine IP-10 in urine, which is used as a marker for diagnosis of infection. The aim of this study was to prove whether IP-10 urine can be a biomarker diagnosis of active lung tuberculosis in HIV-AIDS patients. Design of this study is a cross sectional study involving HIV/AIDS patients with lung tuberculosis as the subject of this study. Forty-seven HIV/AIDS patients with tuberculosis based on clinical and biochemical laboratory were asked to collect urine samples and IP-10/CXCL-10 urine being measured using ELISA method with 18 healthy human urine samples as control. Forty-seven patients diagnosed as HIV/AIDS were included as a subject of this study. HIV/AIDS were more common in male than in women with the percentage in male 85.1% vs. 14.5% of women. In this study, most diagnosed patients were aged 31-40 years old, followed by those 21-30 years, and > 40 years old, with one case diagnosed at age less than 20 years of age. From the result of the urine IP-10 using ELISA method, there was significant increase of the mean value of IP-10 urine in patients with TB-HIV/AIDS co-infection compared to the healthy control with mean 61.05 pg/mL ± 78.01 pg/mL vs. mean 17.2 pg/mL. Based on this research, there was significant increase of urine IP-10/CXCL-10 in active lung tuberculosis with HIV/AIDS compared to the healthy control. From this finding, it is necessary to conduct further research into whether urine IP-10/CXCL-10 plays a significant role in TB-HIV/AIDS co-infection, which can also be used as a biomarker in the early diagnosis of TB-HIV.

Keywords: chemokine, HIV/AIDS, IP-10 urine, tuberculosis

Procedia PDF Downloads 196
8580 To Individualisation of Subject, Donar, by Determination of Serological Markers from Obtain Biological Fluid at Crime Scene

Authors: Arun Kumar, Ravindra Pal Verma, Harsh Sharma, Shani Kumar

Abstract:

For the present study samples was collected from 20 donors with unknown blood group and secretor status had been determined from saliva by using biological fluid. ABO typing on the concentrated samples was successfully performed after 1 month of storage. Urine stained clothing samples are often submitted to forensic science laboratories for ABH blood group antigen determination. The serogenetic markers of semen stains submitted can be used to determine the origin of any of these samples. ABH blood group substances have previously been identified from urine. ABH blood group substance is low in urine in comparison with other body fluids.

Keywords: ABH blood group, crime scene, serological markers, body fluids and urine

Procedia PDF Downloads 542
8579 Learners’ Conspicuous and Significant Errors in Arithmetic

Authors: Michael Lousis

Abstract:

The systematic identification of the most conspicuous and significant errors made by learners during three-years of testing of their progress in learning Arithmetic are presented in this article. How these errors have changed over three-years of school instruction of Arithmetic also is shown. The sample is comprised of two hundred (200) English students and one hundred and fifty (150) Greek students. These students were purposefully selected according to their participation in each testing session in the development of the three-year Kassel Project in England and Greece, in both domains simultaneously in Arithmetic and Algebra. The data sample includes six test-scripts corresponding to three testing sessions in both Arithmetic and Algebra respectively.

Keywords: arithmetic, errors, Kassel Project, progress of learning

Procedia PDF Downloads 237
8578 Effects of Post-sampling Conditions on Ethanol and Ethyl Glucuronide Formation in the Urine of Diabetes Patients

Authors: Hussam Ashwi, Magbool Oraiby, Ali Muyidi, Hamad Al-Oufi, Mohammed Al-Oufi, Adel Al-Juhani, Salman Al-Zemaa, Saeed Al-Shahrani, Amal Abuallah, Wedad Sherwani, Mohammed Alattas, Ibraheem Attafi

Abstract:

Ethanol must be accurately identified and quantified to establish their use and contribution in criminal cases and forensic medicine. In some situations, it may be necessary to reanalyze an old specimen; therefore, it is essential to comprehend the effect of storage conditions and how long the result of a reanalyzed specimen can be reliable and reproducible. Additionally, ethanol can be produced via multiple in vivo and in vitro processes, particularly in diabetic patients, and the results can be affected by storage conditions and time. In order to distinguish between in vivo and in vitro alcohol generation in diabetes patient urine samples, various factors should be considered. This study identifies and quantifies ethanol and EtG in diabetic patients' urine samples stored in two different settings over time. Ethanol levels were determined using gas chromatography-headspace (GC-HS), and ethyl glucuronide (EtG) levels were determined using the immunoassay (RANDOX) technique. Ten urine specimens were collected and placed in a standard container. Each specimen was separated into two containers. The specimens were divided into two groups: those kept at room temperature (25 °C) and those kept cold (2-8 °C). Ethanol and EtG levels were determined serially over a two-week period. Initial results showed that none of the specimens tested positive for ethanol or EtG. At room temperature (15-25 °C), 7 and 14 days after the sample was taken, the average concentration of ethanol increased from 1.7 mg/dL to 2 mg/dL, and the average concentration of EtG increased from 108 ng/mL to 186 ng/mL. At 2–8 °C, the average ethanol concentration was 0.4 and 0.5 mg/dL, and the average EtG concentration was 138 and 124 ng/mL seven and fourteen days after the sample was collected, respectively. When ethanol and EtG levels were determined 14 days post collection, they were considerably lower than when stored at room temperature. A considerable increase in EtG concentrations (14-day range 0–186 ng/mL) is produced during room-temperature storage, although negative initial results for all specimens. Because EtG might be produced after a sampling collection, it is not a reliable indicator of recent alcohol consumption. Given the possibility of misleading EtG results due to in vitro EtG production in the urine of diabetic patients.

Keywords: ethyl glucuronide, ethanol, forensic toxicology, diabetic

Procedia PDF Downloads 83
8577 Automated Java Testing: JUnit versus AspectJ

Authors: Manish Jain, Dinesh Gopalani

Abstract:

Growing dependency of mankind on software technology increases the need for thorough testing of the software applications and automated testing techniques that support testing activities. We have outlined our testing strategy for performing various types of automated testing of Java applications using AspectJ which has become the de-facto standard for Aspect Oriented Programming (AOP). Likewise JUnit, a unit testing framework is the most popular Java testing tool. In this paper, we have evaluated our proposed AOP approach for automated testing and JUnit on various parameters. First we have provided the similarity between the two approaches and then we have done a detailed comparison of the two testing techniques on factors like lines of testing code, learning curve, testing of private members etc. We established that our AOP testing approach using AspectJ has got several advantages and is thus particularly more effective than JUnit.

Keywords: aspect oriented programming, AspectJ, aspects, JU-nit, software testing

Procedia PDF Downloads 289
8576 Detection of Leptospira interrogans in Kidney and Urine of water Buffalo and its Relationship with Histopathological and Serological Findings

Authors: M. R. Haji Hajikolaei, A. A. Nikvand, A. R. Ghadrdan, M. Ghorbanpoor, B. Mohammadian

Abstract:

This study was carried out on water buffalo for detection of Leptospira interrogans in kidney and urine and its relationship with serological findings. Blood, urine and kidney samples were taken immediately after slaughter from 353 water buffalos at Ahvaz abattoir in Khouzestan province, Iran. Sera were initially screened at serum dilution of 1:100 against seven live antigens of Leptospira interrogans: pomona, hardjo, ballum, icterohemorrhagiae, tarasovi, australis and grippotyphosa using the microscopic agglutination test (MAT) and sera with positive results were titrated against reacting antigens in serial twofold dilution from 1:100 to 1:800. The samples of kidney were embedded in paraffin wax and 5µm thick sections were stained routinely with Haematoxylin and Eosin (H&E). Polymerase chain reaction (PCR) examination was done on urine and kidney by using LipL32 gene primers. Antibodies against one or more serovars at dilution >:100 were detected in sera. The most frequent reactor was hardjo (56.2%), followed by pomona (52.3%), australis (9.8%), tarassovi (5.9%), grippotyphosa (4.5%) and icterohaemorrhagiae (3.9%). The L. interrogans were detected in 43 (12.2%) of examined buffaloes, so that 26 (8.2%) of kidney tissues, 14 (4.8%) of urine samples separately and 3 (0.84%) of both kidney and urine samples were positive in PCR. From 153 (43.3%) buffaloes with positive MAT, 24 cases were positive by PCR of kidney and/or urine samples, synchronously. Renal lesions such as interstitial nephritis, acute tubular necrosis (ATN), pyelonephritis, glomerolonephritis, renal fibrosis and hydronephrosis were found in 128 (36.3%) cases. Statistical analysis indicated that there was no significant association between results of MAT, PCR and interstitial nephritis.

Keywords: leptospiral infection, PCR, MAT, histopathology, river buffalo

Procedia PDF Downloads 296
8575 AGEs-Aggravating Renal Lesions in C57BL/6J Mice, STZ-Induced Diabetes Nephropathy Model

Authors: Xing Lv, Hui-Qin Xu

Abstract:

The present study aimed to reveal the mechanism in aggravating STZ induced diabetic nephropathy (DN) by AGEs (advanced glycation end products). At the eighth day, 20 diabetic mice were randomly divided into STZ group and combination (combine AGEs with STZ) group. Simultaneously, AGEs group and normal group were set. Only mice in AGEs group, combination group were fed with high-AGEs diets. Mice diabetic conventional indicators, biochemical analysis were measured. Among the indictors, food consumptions, water intake, urine output, blood glucose, urine protein, urine creatinine, serum urea nitrogen were increased significantly in STZ, combination groups. The AGEs levels in combination group increased significantly when compared with STZ group. Weights and insulin levels in the STZ, combination groups were decreased significantly when compared with normal group, and the difference was significantly between AGEs group and STZ group. As a conclusion, AGEs play an important role in the DN development, inducing kidney damages.

Keywords: AGEs, diabetic nephropathy, serum urea nitrogen, urine protein

Procedia PDF Downloads 397
8574 Machine Learning Approach for Mutation Testing

Authors: Michael Stewart

Abstract:

Mutation testing is a type of software testing proposed in the 1970s where program statements are deliberately changed to introduce simple errors so that test cases can be validated to determine if they can detect the errors. Test cases are executed against the mutant code to determine if one fails, detects the error and ensures the program is correct. One major issue with this type of testing was it became intensive computationally to generate and test all possible mutations for complex programs. This paper used reinforcement learning and parallel processing within the context of mutation testing for the selection of mutation operators and test cases that reduced the computational cost of testing and improved test suite effectiveness. Experiments were conducted using sample programs to determine how well the reinforcement learning-based algorithm performed with one live mutation, multiple live mutations and no live mutations. The experiments, measured by mutation score, were used to update the algorithm and improved accuracy for predictions. The performance was then evaluated on multiple processor computers. With reinforcement learning, the mutation operators utilized were reduced by 50 – 100%.

Keywords: automated-testing, machine learning, mutation testing, parallel processing, reinforcement learning, software engineering, software testing

Procedia PDF Downloads 162
8573 Use of a Chagas Urine Nanoparticle Test (Chunap) to Correlate with Parasitemia Levels in T. cruzi/HIV Co-Infected Patients

Authors: Yagahira E. Castro-Sesquen, Robert H. Gilman, Carolina Mejia, Daniel E. Clark, Jeong Choi, Melissa J. Reimer-Mcatee, Rocio Castro, Jorge Flores, Edward Valencia-Ayala, Faustino Torrico, Ricardo Castillo-Neyra, Lance Liotta, Caryn Bern, Alessandra Luchini

Abstract:

Early diagnosis of reactivation of Chagas disease in HIV patients could be lifesaving; however, in Latin American the diagnosis is performed by detection of parasitemia by microscopy which lacks sensitivity. To evaluate if levels of T. cruzi antigens in urine determined by Chunap (Chagas urine nanoparticle test) are correlated with parasitemia levels in T. cruzi/HIV co-infected patients. T. cruzi antigens in urine of HIV patients (N=55: 31 T. cruzi infected and 24 T. cruzi serology negative) were concentrated using hydrogel particles and quantified by Western Blot and a calibration curve. The percentage of Chagas positive patients determined by Chunap compared to blood microscopy, qPCR, and ELISA was 100% (6/6), 95% (18/19) and 74% (23/31), respectively. Chunap specificity was 91.7%. Linear regression analysis demonstrated a direct relationship between parasitemia levels (determined by qPCR) and urine T. cruzi antigen concentrations (p<0.001). A cut-off of > 105 pg was chosen to determine patients with reactivation of Chagas disease (6/6). Urine antigen concentration was significantly higher among patients with CD4+ lymphocyte counts below 200/mL (p=0.045). Chunap shows potential for early detection of reactivation and with appropriate adaptation can be used for monitoring Chagas disease status in T. cruzi/HIV co-infected patients.

Keywords: antigenuria, Chagas disease, Chunap, nanoparticles, parasitemia, poly N-isopropylacrylamide (NIPAm)/trypan blue particles (polyNIPAm/TB), reactivation of Chagas disease.

Procedia PDF Downloads 340
8572 The Effects of Seasonal Variation on the Microbial-N Flow to the Small Intestine and Prediction of Feed Intake in Grazing Karayaka Sheep

Authors: Mustafa Salman, Nurcan Cetinkaya, Zehra Selcuk, Bugra Genc

Abstract:

The objectives of the present study were to estimate the microbial-N flow to the small intestine and to predict the digestible organic matter intake (DOMI) in grazing Karayaka sheep based on urinary excretion of purine derivatives (xanthine, hypoxanthine, uric acid, and allantoin) by the use of spot urine sampling under field conditions. In the trial, 10 Karayaka sheep from 2 to 3 years of age were used. The animals were grazed in a pasture for ten months and fed with concentrate and vetch plus oat hay for the other two months (January and February) indoors. Highly significant linear and cubic relationships (P<0.001) were found among months for purine derivatives index, purine derivatives excretion, purine derivatives absorption, microbial-N and DOMI. Through urine sampling and the determination of levels of excreted urinary PD and Purine Derivatives / Creatinine ratio (PDC index), microbial-N values were estimated and they indicated that the protein nutrition of the sheep was insufficient. In conclusion, the prediction of protein nutrition of sheep under the field conditions may be possible with the use of spot urine sampling, urinary excreted PD and PDC index. The mean purine derivative levels in spot urine samples from sheep were highest in June, July and October. Protein nutrition of pastured sheep may be affected by weather changes, including rainfall. Spot urine sampling may useful in modeling the feed consumption of pasturing sheep. However, further studies are required under different field conditions with different breeds of sheep to develop spot urine sampling as a model.

Keywords: Karayaka sheep, spot sampling, urinary purine derivatives, PDC index, microbial-N, feed intake

Procedia PDF Downloads 499
8571 Occupational Exposure and Contamination to Antineoplastic Drugs of Healthcare Professionals in Mauritania

Authors: Antoine Villa, Moustapha Mohamedou, Florence Pilliere, Catherine Verdun-Esquer, Mathieu Molimard, Mohamed Sidatt Cheikh El Moustaph, Mireille Canal-Raffin

Abstract:

Context: In Mauritania, the activity of the National Center of Oncology (NCO) has steadily risen leading to an increase in the handling of antineoplastic drugs (AD) by healthcare professionals. In this context, the AD contamination of those professionals is a major concern for occupational physicians. It has been evaluated using biological monitoring of occupational exposure (BMOE). Methods: The intervention took place in 2015, in 2 care units, and evaluated nurses preparing and/or infusing AD and agents in charge of hygiene. Participants provided a single urine sample, at the end of the week, at the end of their shift. Five molecules were sought using specific high sensitivity methods (UHPLC-MS/MS) with very low limits of quantification (LOQ) (cyclophosphamide (CP), Ifosfamide (IF), methotrexate (MTX): 2.5ng/L; doxorubicin (Doxo): 10ng/L; α-fluoro-β-alanine (FBAL, 5-FU metabolite): 20ng/L). A healthcare worker was considered as 'contaminated' when an AD was detected at a urine concentration equal to or greater than the LOQ of the analytical method or at trace concentration. Results: Twelve persons participated (6 nurses, 6 agents in charge of hygiene). Twelve urine samples were collected and analyzed. The percentage of contamination was 66.6% for all participants (n=8/12), 100% for nurses (6/6) and 33% for agents in charge of hygiene (2/6). In 62.5% (n=5/8) of the contaminated workers, two to four of the AD were detected in the urine. CP was found in the urine of all contaminated workers. FBAL was found in four, MTX in three and Doxo in one. Only IF was not detected. Urinary concentrations (all drugs combined) ranged from 3 to 844 ng/L for nurses and from 3 to 44 ng/L for agents in charge of hygiene. The median urinary concentrations were 87 ng/L, 15.1 ng/L and 4.4 ng/L for FBAL, CP and MTX, respectively. The Doxo urinary concentration was found 218ng/L. Discussion: There is no current biological exposure index for the interpretation of AD contamination. The contamination of these healthcare professionals is therefore established by the detection of one or more AD in urine. These urinary contaminations are higher than the LOQ of the analytical methods, which must be as low as possible. Given the danger of AD, the implementation of corrective measures is essential for the staff. Biological monitoring of occupational exposure is the most reliable process to identify groups at risk, tracing insufficiently controlled exposures and as an alarm signal. These results show the necessity to educate professionals about the risks of handling AD and/or to care for treated patients.

Keywords: antineoplastic drugs, Mauritania, biological monitoring of occupational exposure, contamination

Procedia PDF Downloads 270
8570 Detection of Heroin and Its Metabolites in Urine Samples: A Chemiluminescence Approach

Authors: Sonu Gandhi, Neena Capalash, Prince Sharma, C. Raman Suri

Abstract:

A sensitive chemiluminescence immunoassay (CIA) for heroin and its major metabolites is reported. The method is based on the competitive reaction of horseradish peroxidase (HRP)-labeled anti-MAM antibody and free drug in spiked urine samples. A hapten-protein conjugate was synthesized by using acidic derivative of monoacetyl morphine (MAM) coupled to carrier protein BSA and was used as an immunogen for the generation of anti-MAM (monoacetyl morphine) antibody. A high titer of antibody (1:64,0000) was obtained and the relative affinity constant (Kaff) of antibody was 3.1×107 l/mol. Under the optimal conditions, linear range and reactivity for heroin, mono acetyl morphine (MAM), morphine and codeine were 0.08, 0.09, 0.095 and 0.092 ng/mL respectively. The developed chemiluminescence inhibition assay could detect heroin and its metabolites in standard and urine samples up to 0.01 ng/ml.

Keywords: heroin, metabolites, chemiluminescence immunoassay, horse radish peroxidase

Procedia PDF Downloads 234
8569 Analyzing the Effectiveness of Different Testing Techniques in Ensuring Software Quality

Authors: R. M. P. C. Bandara, M. L. L. Weerasinghe, K. T. C. R. Kumari, A. G. D. R. Hansika, D. I. De Silva, D. M. T. H. Dias

Abstract:

Software testing is an essential process in software development that aims to identify defects and ensure that software is functioning as intended. Various testing techniques are employed to achieve this goal, but the effectiveness of these techniques varies. This research paper analyzes the effectiveness of different testing techniques in ensuring software quality. The paper explores different testing techniques, including manual and automated testing, and evaluates their effectiveness in terms of identifying defects, reducing the number of defects in software, and ensuring that software meets its functional and non-functional requirements. Moreover, the paper will also investigate the impact of factors such as testing time, test coverage, and testing environment on the effectiveness of these techniques. This research aims to provide valuable insights into the effectiveness of different testing techniques, enabling software development teams to make informed decisions about the testing approach that is best suited to their needs. By improving testing techniques, the number of defects in software can be reduced, enhancing the quality of software and ultimately providing better software for users.

Keywords: software testing life cycle, software testing techniques, software testing strategies, effectiveness, software quality

Procedia PDF Downloads 46
8568 Methods of Variance Estimation in Two-Phase Sampling

Authors: Raghunath Arnab

Abstract:

The two-phase sampling which is also known as double sampling was introduced in 1938. In two-phase sampling, samples are selected in phases. In the first phase, a relatively large sample of size is selected by some suitable sampling design and only information on the auxiliary variable is collected. During the second phase, a sample of size is selected either from, the sample selected in the first phase or from the entire population by using a suitable sampling design and information regarding the study and auxiliary variable is collected. Evidently, two phase sampling is useful if the auxiliary information is relatively easy and cheaper to collect than the study variable as well as if the strength of the relationship between the variables and is high. If the sample is selected in more than two phases, the resulting sampling design is called a multi-phase sampling. In this article we will consider how one can use data collected at the first phase sampling at the stages of estimation of the parameter, stratification, selection of sample and their combinations in the second phase in a unified setup applicable to any sampling design and wider classes of estimators. The problem of the estimation of variance will also be considered. The variance of estimator is essential for estimating precision of the survey estimates, calculation of confidence intervals, determination of the optimal sample sizes and for testing of hypotheses amongst others. Although, the variance is a non-negative quantity but its estimators may not be non-negative. If the estimator of variance is negative, then it cannot be used for estimation of confidence intervals, testing of hypothesis or measure of sampling error. The non-negativity properties of the variance estimators will also be studied in details.

Keywords: auxiliary information, two-phase sampling, varying probability sampling, unbiased estimators

Procedia PDF Downloads 555
8567 Bisphenol-A Concentrations in Urine and Drinking Water Samples of Adults Living in Ankara

Authors: Hasan Atakan Sengul, Nergis Canturk, Bahar Erbas

Abstract:

Drinking water is indispensable for life. With increasing awareness of communities, the content of drinking water and tap water has been a matter of curiosity. The presence of Bisphenol-A is the top one when content curiosity is concerned. The most used chemical worldwide for production of polycarbonate plastics and epoxy resins is Bisphenol-A. People are exposed to Bisphenol-A chemical, which disrupts the endocrine system, almost every day. Each year it is manufactured an average of 5.4 billion kilograms of Bisphenol-A. Linear formula of Bisphenol-A is (CH₃)₂C(C₆H₄OH)₂, its molecular weight is 228.29 and CAS number is 80-05-7. Bisphenol-A is known to be used in the manufacturing of plastics, along with various chemicals. Bisphenol-A, an industrial chemical, is used in the raw materials of packaging mate-rials in the monomers of polycarbonate and epoxy resins. The pass through the nutrients of Bisphenol-A substance happens by packaging. This substance contaminates with nutrition and penetrates into body by consuming. International researches show that BPA is transported through body fluids, leading to hormonal disorders in animals. Experimental studies on animals report that BPA exposure also affects the gender of the newborn and its time to reach adolescence. The extent to what similar endocrine disrupting effects are on humans is a debate topic in many researches. In our country, detailed studies on BPA have not been done. However, it is observed that 'BPA-free' phrases are beginning to appear on plastic packaging such as baby products and water carboys. Accordingly, this situation increases the interest of the society about the subject; yet it causes information pollution. In our country, all national and international studies on exposure to BPA have been examined and Ankara province has been designated as testing region. To assess the effects of plastic use in daily habits of people and the plastic amounts removed out of the body, the results of the survey conducted with volunteers who live in Ankara has been analyzed with Sciex appliance by means of LC-MS/MS in the laboratory and the amount of exposure and BPA removal have been detected by comparing the results elicited before. The results have been compared with similar studies done in international arena and the relation between them has been exhibited. Consequently, there has been found no linear correlation between the amount of BPA in drinking water and the amount of BPA in urine. This has also revealed that environmental exposure and the habits of daily plastic use have also direct effects a human body. When the amount of BPA in drinking water is considered; minimum 0.028 µg/L, maximum 1.136 µg/L, mean 0.29194 µg/L and SD(standard deviation)= 0.199 have been detected. When the amount of BPA in urine is considered; minimum 0.028 µg/L, maximum 0.48 µg/L, mean 0.19181 µg/L and SD= 0.099 have been detected. In conclusion, there has been found no linear correlation between the amount of BPA in drinking water and the amount of BPA in urine (r= -0.151). The p value of the comparison between drinking water’s and urine’s BPA amounts is 0.004 which shows that there is a significant change and the amounts of BPA in urine is dependent on the amounts in drinking waters (p < 0.05). This has revealed that environmental exposure and daily plastic habits have also direct effects on the human body.

Keywords: analyze of bisphenol-A, BPA, BPA in drinking water, BPA in urine

Procedia PDF Downloads 103
8566 A Comparative Study of Three Major Performance Testing Tools

Authors: Abdulaziz Omar Alsadhan, Mohd Mudasir Shafi

Abstract:

Performance testing is done to prove the reliability of any software product. There are a number of tools available in the markets that are used to perform performance testing. In this paper we present a comparative study of the three most commonly used performance testing tools. These tools cover the major share of the performance testing market and are widely used. In this paper we compared the tools on five evaluation parameters which are; User friendliness, portability, tool support, compatibility and cost. The conclusion provided at the end of the paper is based on our study and does not support any tool or company.

Keywords: software development, software testing, quality assurance, performance testing, load runner, rational testing, silk performer

Procedia PDF Downloads 565
8565 Urinary Volatile Organic Compound Testing in Fast-Track Patients with Suspected Colorectal Cancer

Authors: Godwin Dennison, C. E. Boulind, O. Gould, B. de Lacy Costello, J. Allison, P. White, P. Ewings, A. Wicaksono, N. J. Curtis, A. Pullyblank, D. Jayne, J. A. Covington, N. Ratcliffe, N. K. Francis

Abstract:

Background: Colorectal symptoms are common but only infrequently represent serious pathology, including colorectal cancer (CRC). A large number of invasive tests are presently performed for reassurance. We investigated the feasibility of urinary volatile organic compound (VOC) testing as a potential triage tool in patients fast-tracked for assessment for possible CRC. Methods: A prospective, multi-centre, observational feasibility study was performed across three sites. Patients referred on NHS fast-track pathways for potential CRC provided a urine sample which underwent Gas Chromatography Mass Spectrometry (GC-MS), Field Asymmetric Ion Mobility Spectrometry (FAIMS) and Selected Ion Flow Tube Mass Spectrometry (SIFT-MS) analysis. Patients underwent colonoscopy and/or CT colonography and were grouped as either CRC, adenomatous polyp(s), or controls to explore the diagnostic accuracy of VOC output data supported by an artificial neural network (ANN) model. Results: 558 patients participated with 23 (4.1%) CRC diagnosed. 59% of colonoscopies and 86% of CT colonographies showed no abnormalities. Urinary VOC testing was feasible, acceptable to patients, and applicable within the clinical fast track pathway. GC-MS showed the highest clinical utility for CRC and polyp detection vs. controls (sensitivity=0.878, specificity=0.882, AUROC=0.884). Conclusion: Urinary VOC testing and analysis are feasible within NHS fast-track CRC pathways. Clinically meaningful differences between patients with cancer, polyps, or no pathology were identified therefore suggesting VOC analysis may have future utility as a triage tool. Acknowledgment: Funding: NIHR Research for Patient Benefit grant (ref: PB-PG-0416-20022).

Keywords: colorectal cancer, volatile organic compound, gas chromatography mass spectrometry, field asymmetric ion mobility spectrometry, selected ion flow tube mass spectrometry

Procedia PDF Downloads 49