25 Design of Demand Pacemaker Using an Embedded Controller

Authors: C. Bala Prashanth Reddy, B. Abhinay, C. Sreekar, D. V. Shobhana Priscilla

Abstract:

The project aims in designing an emergency pacemaker which is capable of giving shocks to a human heart which has stopped working suddenly. A pacemaker is a machine commonly used by cardiologists. This machine is used in order to shock a human’s heart back into usage. The way the heart works is that there are small cells called pacemakers sending electrical pulses to cardiac muscles that tell the heart when to pump blood. When these electrical pulses stop, the heart stops beating. When this happens, a pacemaker is used to shock the heart muscles and the pacemakers back into action. The way this is achieved is by rubbing the two panels of the pacemaker together to create an adequate electrical current, and then the heart gets back to the normal state. The project aims in designing a system which is capable of continuously displaying the heart beat and blood pressure of a person on LCD. The concerned doctor gets the heart beat and also the blood pressure details continuously through the GSM Modem in the form of SMS alerts. In case of abnormal condition, the doctor sends message format regarding the amount of electric shock needed. Automatically the microcontroller gives the input to the pacemaker which in turn gives the shock to the patient. Heart beat monitor and display system is a portable and a best replacement for the old model stethoscope which is less efficient. The heart beat rate is calculated manually using stethoscope where the probability of error is high because the heart beat rate lies in the range of 70 to 90 per minute whose occurrence is less than 1 sec, so this device can be considered as a very good alternative instead of a stethoscope.

Keywords: missing R wave, PWM, demand pacemaker, heart

Procedia PDF Downloads 431
24 Cardiac Pacemaker in a Patient Undergoing Breast Radiotherapy-Multidisciplinary Approach

Authors: B. Petrović, M. Petrović, L. Rutonjski, I. Djan, V. Ivanović

Abstract:

Objective: Cardiac pacemakers are very sensitive to radiotherapy treatment from two sources: electromagnetic influence from the medical linear accelerator producing ionizing radiation- influencing electronics within the pacemaker, and the absorption of dose to the device. On the other hand, patients with cardiac pacemakers at the place of a tumor are rather rare, and single clinic hardly has experience with the management of such patients. The widely accepted international guidelines for management of radiation oncology patients recommend that these patients should be closely monitored and examined before, during and after radiotherapy treatment by cardiologist, and their device and condition followed up. The number of patients having both cancer and pacemaker, is growing every year, as both cancer incidence, as well as cardiac diseases incidence, are inevitably growing figures. Materials and methods: Female patient, age 69, was diagnozed with valvular cardiomyopathy and got implanted a pacemaker in 2005 and prosthetic mitral valve in 1993 (cancer was diagnosed in 2012). She was stable cardiologically and came to radiation therapy department with the diagnosis of right breast cancer, with the tumor in upper lateral quadrant of the right breast. Since she had all lymph nodes positive (28 in total), she had to have irradiated the supraclavicular region, as well as the breast with the tumor bed. She previously received chemotherapy, approved by the cardiologist. The patient was estimated to be with the high risk as device was within the field of irradiation, and the patient had high dependence on her pacemaker. The radiation therapy plan was conducted as 3D conformal therapy. The delineated target was breast with supraclavicular region, where the pacemaker was actually placed, with the addition of a pacemaker as organ at risk, to estimate the dose to the device and its components as recommended, and the breast. The targets received both 50 Gy in 25 fractions (where 20% of a pacemaker received 50 Gy, and 60% of a device received 40 Gy). The electrode to the heart received between 1 Gy and 50 Gy. Verification of dose planned and delivered was performed. Results: Evaluation of the patient status according to the guidelines and especially evaluation of all associated risks to the patient during treatment was done. Patient was irradiated by prescribed dose and followed up for the whole year, with no symptoms of failure of the pacemaker device during, or after treatment in follow up period. The functionality of a device was estimated to be unchanged, according to the parameters (electrode impedance and battery energy). Conclusion: Patient was closely monitored according to published guidelines during irradiation and afterwards. Pacemaker irradiated with the full dose did not show any signs of failure despite recommendations data, but in correlation with other published data.

Keywords: cardiac pacemaker, breast cancer, radiotherapy treatment planning, complications of treatment

Procedia PDF Downloads 401
23 A Comparative Study on a Tilt-Integral-Derivative Controller with Proportional-Integral-Derivative Controller for a Pacemaker

Authors: Aysan Esgandanian, Sabalan Daneshvar

Abstract:

The study is done to determine the comparison between proportional-integral-derivative controller (PID controller) and tilt-integral-derivative (TID controller) for cardiac pacemaker systems, which can automatically control the heart rate to accurately track a desired preset profile. The controller offers good adaption of heart to the physiological needs of the patient. The parameters of the both controllers are tuned by particle swarm optimization (PSO) algorithm which uses the integral of time square error as a fitness function to be minimized. Simulation results are performed on the developed cardiovascular system of humans and results demonstrate that the TID controller produces superior control performance than PID controllers. In this paper, all simulations were performed in Matlab.

Keywords: integral of time square error, pacemaker systems, proportional-integral-derivative controller, PSO algorithm, tilt-integral-derivative controller

Procedia PDF Downloads 423
22 Powering Pacemakers from Heart Pressure Variation with Piezoelectric Energy Harvesters

Authors: A. Mathieu, B. Aubry, E. Chhim, M. Jobe, M. Arnaud

Abstract:

Present project consists in a study and a development of piezoelectric devices for supplying power to new generation pacemakers. They are miniaturized leadless implants without battery placed directly in right ventricle. Amongst different acceptable energy sources in cardiac environment, we choose the solution of a device based on conversion of the energy produced by pressure variation inside the heart into electrical energy. The proposed energy harvesters can meet the power requirements of pacemakers, and can be a good solution to solve the problem of regular surgical operation. With further development, proposed device should provide enough energy to allow pacemakers autonomy, and could be good candidate for next pacemaker generation.

Keywords: energy harvester, heart, leadless pacemaker, piezoelectric cells, pressure variation

Procedia PDF Downloads 412
21 Study on the Transition to Pacemaker of Two Coupled Neurons

Authors: Sun Zhe, Ruggero Micheletto

Abstract:

The research of neural network is very important for the development of advanced next generation intelligent devices and the medical treatment. The most important part of the neural network research is the learning. The process of learning in our brain is essentially several adjustment processes of connection strength between neurons. It is very difficult to figure out how this mechanism works in the complex network and how the connection strength influences brain functions. For this reason, we made a model with only two coupled neurons and studied the influence of connection strength between them. To emulate the neuronal activity of realistic neurons, we prefer to use the Izhikevich neuron model. This model can simulate the neuron variables accurately and it’s simplicity is very suitable to implement on computers. In this research, the parameter ρ is used to estimate the correlation coefficient between spike train of two coupling neurons.We think the results is very important for figuring out the mechanism between synchronization of coupling neurons and synaptic plasticity. The result also presented the importance of the spike frequency adaptation in complex systems.

Keywords: neural networks, noise, stochastic processes, coupled neurons, correlation coefficient, synchronization, pacemaker, synaptic plasticity

Procedia PDF Downloads 238
20 Anaesthetic Management of Congenitally Corrected Transposition of Great Arteries with Complete Heart Block in a Parturient for Emergency Caesarean Section

Authors: Lokvendra S. Budania, Yogesh K Gaude, Vamsidhar Chamala

Abstract:

Introduction: Congenitally corrected transposition of great arteries (CCTGA) is a complex congenital heart disease where there are both atrioventricular and ventriculoarterial discordances, usually accompanied by other cardiovascular malformations. Case Report: A 24-year-old primigravida known case of CCTGA at 37 weeks of gestation was referred to our hospital for safe delivery. Her electrocardiogram showed HR-40/pm, echocardiography showed Ejection Fraction of 65% and CCTGA. Temporary pacemaker was inserted by cardiologist in catheterization laboratory, before giving trial of labour in view of complete heart block. She was planned for normal delivery, but emergency Caesarean section was planned due to non-reassuring foetal Cardiotocography Pre-op vitals showed PR-50 bpm with temporary pacemaker, Blood pressure-110/70 mmHg, SpO2-99% on room air. Nil per oral was inadequate. Patency of two peripheral IV cannula checked and left radial arterial line secured. Epidural Anaesthesia was planned, and catheter was placed at L2-L3. Test dose was given, Anaesthesia was provided with 5ml + 5ml of 2% Lignocaine with 25 mcg Fentanyl and further 2.5Ml of 0.5% Bupivacaine was given to achieve a sensory level of T6. Cesarean section was performed and baby was delivered. Cautery was avoided during this procedure. IV Oxytocin (15U) was added to 500 mL of ringer’s lactate. Hypotension was treated with phenylephrine boluses. Patient was shifted to post-operative care unit and later to high dependency unit for monitoring. Post op vitals remained stable. Temporary pacemaker was removed after 24 hours of surgery. Her post-operative period was uneventful and discharged from hospital. Conclusion: Rare congenital cardiac disorders require detail knowledge of pathophysiology and associated comorbidities with the disease. Meticulously planned and carefully titrated neuraxial techniques will be beneficial for such cases.

Keywords: congenitally corrected transposition of great arteries, complete heart block, emergency LSCS, epidural anaesthesia

Procedia PDF Downloads 86
19 Comparison of Peri- and Post-Operative Outcomes of Three Left Atrial Incisions: Conventional Direct, Transseptal and Superior Septal Left Atriotomy

Authors: Estelle Démoulin, Dionysios Adamopoulos, Tornike Sologashvili, Mathieu Van Steenberghe, Jalal Jolou, Haran Burri, Christoph Huber, Mustafa Cikirikcioglu

Abstract:

Background & objective: Mitral valve surgeries are mainly performed by median sternotomy with conventional direct atriotomy. Good exposure to the mitral valve is challenging, especially for acute pathologies, where left atrium dilation does not occur. Other atriotomies, such as transseptal or superior septal, are used as they allow better access and visualization. Peri- and postoperative outcomes of these three different left atriotomies were compared. Methods: Patients undergoing mitral valve surgery between January 2010 and December 2020 were included and divided into three groups: group 1 (conventional direct, n=115), group 2 (transseptal, n=33) and group 3 (superior septal, n=59). To improve the sampling size, all patients underwent mitral valve surgery with or without associated procedures (CABG, aortic-tricuspid surgery, Maze procedure). The study protocol was approved by SwissEthics. Results: No difference was shown for the etiology of mitral valve disease, except endocarditis, which was more frequent in group 3 (p = 0.014). Elective surgeries and isolated mitral valve surgery were more frequent in group 1 (p = 0.008, p = 0.011) and aortic clamping and cardiopulmonary bypass were shorter (p = 0.002, p<0.001). Group 3 had more emergency procedures (p = 0.011) and longer lengths of intensive care unit and hospital stay (p = 0.000, p = 0.003). There was no difference in permanent pacemaker implantation, postoperative complications and mortality between the groups. Conclusion: Mitral valve surgeries can be safely performed using those three left atriotomies. Conventional direct may lead to shorter aortic clamping and cardiopulmonary bypass times. Superior septal is mostly used for acute pathologies, and it does not increase postoperative arrhythmias and permanent pacemaker implantation. However, intensive care unit and hospital lengths of stay were found to be longer in this group. In our opinion, this outcome is more related to the pathology and type of surgery than the incision itself.

Keywords: Mitral valve surgery, cardiac surgery, atriotomy, Operative outcomes

Procedia PDF Downloads 39
18 Evidence-Based in Telemonitoring of Users with Pacemakers at Five Years after Implant: The Poniente Study

Authors: Antonio Lopez-Villegas, Daniel Catalan-Matamoros, Remedios Lopez-Liria

Abstract:

Objectives: The purpose of this study was to analyze clinical data, health-related quality of life (HRQoL) and functional capacity of patients using a telemonitoring follow-up system (TM) compared to patients followed-up through standard outpatient visits (HM) 5 years after the implantation of a pacemaker. Methods: This is a controlled, non-randomised, nonblinded clinical trial, with data collection carried out at 5 years after the pacemakers implant. The study was developed at Hospital de Poniente (Almeria, Spain), between October 2012 and November 2013. The same clinical outcomes were analyzed in both follow-up groups. Health-Related Quality of Life and Functional Capacity was assessed through EuroQol-5D (EQ-5D) questionnaire and Duke Activity Status Index (DASI) respectively. Sociodemographic characteristics and clinical data were also analyzed. Results: 5 years after pacemaker implant, 55 of 82 initial patients finished the study. Users with pacemakers were assigned to either a conventional follow-up group at hospital (HM=34, 50 initials) or a telemonitoring system group (TM=21, 32 initials). No significant differences were found between both groups according to sociodemographic characteristics, clinical data, Health-Related Quality of Life and Functional Capacity according to medical record and EQ5D and DASI questionnaires. In addition, conventional follow-up visits to hospital were reduced in 44,84% (p < 0,001) in the telemonitoring group in relation to hospital monitoring group. Conclusion: Results obtained in this study suggest that the telemonitoring of users with pacemakers is an equivalent option to conventional follow-up at hospital, in terms of Health-Related Quality of Life and Functional Capacity. Furthermore, it allows for the early detection of cardiovascular and pacemakers-related problem events and significantly reduces the number of in-hospital visits. Trial registration: ClinicalTrials.gov NCT02234245. The PONIENTE study has been funded by the General Secretariat for Research, Development and Innovation, Regional Government of Andalusia (Spain), project reference number PI/0256/2017, under the research call 'Development and Innovation Projects in the Field of Biomedicine and Health Sciences', 2017.

Keywords: cardiovascular diseases, health-related quality of life, pacemakers follow-up, remote monitoring, telemedicine

Procedia PDF Downloads 92
17 Application First and Second Digits Number in the Benford Law

Authors: Teguh Sugiarto

Abstract:

Background: This study aims to explore the fraud that occurred in the financial statements using the Benford distribution law of 1st and 2nd case study of PT AKR Corporindo Tbk. Research Methods: In this study the authors use the first digit of the analysis and the analysis of the second digit of Bedford’s law. Having obtained the results of the analysis of the first and second digits, authors will make the difference between implementations using the scale above and below 5%. The number that has the level of difference in the range of 5% above or below, then a financial report in may, to analyse in the followup to the direction of the audit investigation, and authors assume happens a confusion in the financial statements. Findings: From research done, we found that there was a difference in the results of the appearance of the first digit of the number with the proper use of Benford's law, according to PT AKR Corporindo financial reports Tbk for the fiscal year 2006-2010, above and below the level the difference in set 5%. Conclusions: From the research that has been done, it can be concluded that on PT AKR Corporindo financial report 2006, 2007, 2008, 2009 and 2010, there is a level difference of appearance of numbers according to Benford's law is significant, as presented in the table analysis.

Keywords: Benford law, first digits, second digits, Indonesian company

Procedia PDF Downloads 389
16 An Examination of the Effects of Implantable Technologies on the Practices of Governmentality

Authors: Benn Van Den Ende

Abstract:

Over the last three decades, there has been an exponential increase in developments in implantable technologies such as the cardiac pacemaker, bionic prosthesis, and implantable chips. The effect of these technologies has been well researched in many areas. However, there is a lack of critical research in security studies. This paper will provide preliminary findings to an ongoing research project which aims to examine how implantable technologies effect the practices of governmentality in the context of security. It will do this by looking at the practices and techniques of governmentality along with different implantable technologies which increase, change or otherwise affect governmental practices. The preliminary research demonstrates that implantable technologies have a profound effect on the practices of governmentality, while also paving the way for further research into a potential ‘new’ form of governmentality in relation to these implantable technologies.

Keywords: critical security studies, governmentality, security theory, political theory, Foucault

Procedia PDF Downloads 145
15 Possible Exposure of Persons with Cardiac Pacemakers to Extremely Low Frequency (ELF) Electric and Magnetic Fields

Authors: Leena Korpinen, Rauno Pääkkönen, Fabriziomaria Gobba, Vesa Virtanen

Abstract:

The number of persons with implanted cardiac pacemakers (PM) has increased in Western countries. The aim of this paper is to investigate the possible situations where persons with a PM may be exposed to extremely low frequency (ELF) electric (EF) and magnetic fields (MF) that may disturb their PM. Based on our earlier studies, it is possible to find such high public exposure to EFs only in some places near 400 kV power lines, where an EF may disturb a PM in unipolar mode. Such EFs cannot be found near 110 kV power lines. Disturbing MFs can be found near welding machines. However, we do not have measurement data from welding. Based on literature and earlier studies at Tampere University of Technology, it is difficult to find public EF or MF exposure that is high enough to interfere with PMs.

Keywords: cardiac pacemaker, electric field, magnetic field, electrical engineering

Procedia PDF Downloads 392
14 The Effect of Meta-Cognitive Therapy on Meta-Cognitive Defects and Emotional Regulation in Substance Dependence Patients

Authors: Sahra Setorg

Abstract:

The purpose of this study was to determine the effect of meta-cognitive therapy on meta-cognitive defects and emotional regulation in industrial substance dependence patients. This quasi-experimental research was conducted with post-test and two-month follow-up design with control and experimental groups. The statistical population consisted of all industrial Substance dependence patients refer to addictive withdrawal clinics in Esfahan city, in Iran in 2013. 45 patients were selected from three clinics through the convenience sampling method and were randomly divided into two experimental groups (15 crack dependences, 15 amphetamine dependences) and one control group (n=15). The meta-cognitive questionnaire (MCQ) and difficulties in emotional regulation questionnaire (DERS) were used as pre-test measures and the experimental groups (crack and amphetamine) received 8 MC therapy sessions in groups. The data were analyzed via multivariate covariance statistic method by spss-18. The results showed that MCT had a significant effect in improving the meta-cognitive defects in crack and amphetamine dependences. Also, this therapy can increase the emotional regulation in both groups (p<0/05).The effect of this therapy is confirmed in two months followup. According to these findings, met-cognitive is as an interface and important variable in prevention, control, and treatment of the new industrial substance dependences.

Keywords: meta-cognitive therapy, meta-cognitive defects, emotional regulation, substance dependence disorder

Procedia PDF Downloads 464
13 An Inverse Docking Approach for Identifying New Potential Anticancer Targets

Authors: Soujanya Pasumarthi

Abstract:

Inverse docking is a relatively new technique that has been used to identify potential receptor targets of small molecules. Our docking software package MDock is well suited for such an application as it is both computationally efficient, yet simultaneously shows adequate results in binding affinity predictions and enrichment tests. As a validation study, we present the first stage results of an inverse-docking study which seeks to identify potential direct targets of PRIMA-1. PRIMA-1 is well known for its ability to restore mutant p53's tumor suppressor function, leading to apoptosis in several types of cancer cells. For this reason, we believe that potential direct targets of PRIMA-1 identified in silico should be experimentally screened for their ability to inhibitcancer cell growth. The highest-ranked human protein of our PRIMA-1 docking results is oxidosqualene cyclase (OSC), which is part of the cholesterol synthetic pathway. The results of two followup experiments which treat OSC as a possible anti-cancer target are promising. We show that both PRIMA-1 and Ro 48-8071, a known potent OSC inhibitor, significantly reduce theviability of BT-474 breast cancer cells relative to normal mammary cells. In addition, like PRIMA-1, we find that Ro 48-8071 results in increased binding of mutant p53 to DNA in BT- 474cells (which highly express p53). For the first time, Ro 48-8071 is shown as a potent agent in killing human breast cancer cells. The potential of OSC as a new target for developing anticancer therapies is worth further investigation.

Keywords: inverse docking, in silico screening, protein-ligand interactions, molecular docking

Procedia PDF Downloads 402
12 Modeling and Design of Rectenna for Low Power Medical Implants

Authors: Madhav Pant, Khem N. Poudel

Abstract:

Wireless power transfer is continuously becoming more powerful and compact in medical implantable devices and the wide range of applications. A rectenna is designed for wireless power transfer technique that can be applied to medical implant devices. The experiment is performed using ANSYS HFSS, a full wave electromagnetic simulation. The dipole antenna combinations operating at 2.4 GHz are used for wireless power transfer and the maximum DC voltage reception by the implant considering International Commission on Non-Ionizing Radiation Protection (ICNIRP) regulation. The power receiving dipole antenna is placed inside the cylindrical geometry having the similar properties of the human body at the frequency of 2.4 GHz. Our design can provide the power at the depth of 5 mm skin and 5mm of bone for the implant. The voltage doubler/quadrupler rectifier in ANSYS Simplorer is used to calculate the exact DC current utilized by implant inside the human body. The qualitative design and analysis of this wireless power transfer method could also be used for other biomedical implants systems such as cardiac pacemaker, insulin pump, and retinal implants.

Keywords: dipole antenna, medical implants, wireless power transfer, rectifier

Procedia PDF Downloads 132
11 Analysis of Cardiovascular Diseases Using Artificial Neural Network

Authors: Jyotismita Talukdar

Abstract:

In this paper, a study has been made on the possibility and accuracy of early prediction of several Heart Disease using Artificial Neural Network. (ANN). The study has been made in both noise free environment and noisy environment. The data collected for this analysis are from five Hospitals. Around 1500 heart patient’s data has been collected and studied. The data is analysed and the results have been compared with the Doctor’s diagnosis. It is found that, in noise free environment, the accuracy varies from 74% to 92%and in noisy environment (2dB), the results of accuracy varies from 62% to 82%. In the present study, four basic attributes considered are Blood Pressure (BP), Fasting Blood Sugar (FBS), Thalach (THAL) and Cholesterol (CHOL.). It has been found that highest accuracy(93%), has been achieved in case of PPI( Post-Permanent-Pacemaker Implementation ), around 79% in case of CAD(Coronary Artery disease), 87% in DCM (Dilated Cardiomyopathy), 89% in case of RHD&MS(Rheumatic heart disease with Mitral Stenosis), 75 % in case of RBBB +LAFB (Right Bundle Branch Block + Left Anterior Fascicular Block), 72% for CHB(Complete Heart Block) etc. The lowest accuracy has been obtained in case of ICMP (Ischemic Cardiomyopathy), about 38% and AF( Atrial Fibrillation), about 60 to 62%.

Keywords: coronary heart disease, chronic stable angina, sick sinus syndrome, cardiovascular disease, cholesterol, Thalach

Procedia PDF Downloads 140
10 Investigating the Efficacy of HIV/AIDS Psycho-Education and Behavioural Skills Training in Reducing Sexual Risk Behaviours in a Trucking Population in Nigeria

Authors: Abiodun Musbau Lawal, Benjamin Oladapo Olley

Abstract:

Long Distance Truck Drivers (LDTDs) have been found to be a high-risk group in the spread of HIV/AIDS globally; perhaps, due to their high Sexual Risk Behaviours (SRBs). Interventions for reducing SRBs in trucking population have not been fully exploited. A quasi-experimental control group pretest-posttest design was used to assess the efficacy of psycho-education and behavioural skills training in reducing SRBs among LDTDs. Sixteen drivers rivers were randomly assigned into either experimental or control groups using balloting technique. A questionnaire was used as an instrument for data collection. Repeated measures t-test and independent t-test were used to test hypotheses. The intervention had a significant effect on the SRBs among LDTDs at post-test(t{7}=6.01, p<.01) and at followup (t{7}=6.42, p<.01). No significant difference in sexual risk behaviour of LDTDs at post-test and at follow-up stage. Similarly, intervention had significant effects on sexual risk behaviour at post-test (t {14}=- 4.69, p<.05) and at follow-up (t {14}= -9.56, p < .05) respectively. At post-test and follow-up stages, drivers in experimental group reported reduced SRBs than those in the control group. Drivers in an experimental group reported lower sexual risk behaviour a week after intervention as well as at three months follow-up than those in the control group. It is concluded that HIV/AIDS preventive intervention that provides the necessary informational and behavioural skills content can significantly impact long distance truck drivers sexual risk behaviours.

Keywords: HIV/AIDS interventions, long distance truck drivers, Nigeria, sexual risk behaviours

Procedia PDF Downloads 443
9 Rituximab Therapy for Musculoskeletal Involvement in Systemic Sclerosis

Authors: Liudmila Garzanova, Lidia Ananyeva, Olga Koneva, Olga Ovsyannikova, Oxana Desinova, Mayya Starovoytova, Rushana Shayahmetova, Anna Khelkovskaya-Sergeeva

Abstract:

Objectives. There is very few data on changes of the musculoskeletal manifestations (artritis, arthralgia, muscle weakness, etc.) in systemic sclerosis (SSc) on rituximab (RTX) therapy. The aim of our study was to assess the severity of the musculoskeletal involvement in SSc patients (pts) and its changes during RTX therapy. Methods. Our study included 103 pts with SSc. The mean followup period was 12.6±10.7 months. The mean age was 47±12.9 years, female-87 pts (84%), the diffuse cutaneous subset of the disease had 55 pts (53%). The mean disease duration was 6.2±5.5 years. All pts had interstitial lung disease (ILD) and were positive for ANA, 67% of them were positive for antitopoisomerase-1. All patients received prednisolone at a dose of 11.3±4.5 mg/day, immunosuppressants at inclusion received 47% of them. Pts received RTX due to the ineffectiveness of previous therapy for ILD. The cumulative mean dose of RTX was 1.7±0.6 grams. Arthritis was observed in 22 pts (21%), arthralgias in 47 pts (46%). Muscle weakness was observed in 17 pts (17%). Tendon friction rubs was established in 7 pts (7%). The results at baseline and at the end of the follow up are presented in the form of mean values. Results. There was an improvement of all outcome parameters and musculoskeletal manifestations on RTX therapy. There was a decrease in the number of pts with arthritis from 22 (21%) to 10 (9%), a decrease in the number of pts with arthralgias from 47 (46%) to 31 (30%). The number of pts with muscle weakness decreased from 17 (17%) to 7 (7%). The number of pts with tendon friction rubs decreased from 7 (7%) to 3 (3%). The creatine phosphokinase decreased from 365.5±186 to 70.8±50.4 (p=0.00006). The C-reactive protein (CRP) decreased from 23.2±31.3 to 8.62±7.4 (p=0.001). The dose of prednisolone was reduced from 11.3±4.5 to 9.8±3.5 mg/day (p=0.0004). Conclusion. In our study, musculoskeletal involvement was detected in almost half of the patients with SSc-ILD. There was an improvement of musculoskeletal manifestations despite a small cumulative dose of RTX. We also managed to reduce the dose of glucocorticosteroids. The improvement of musculoskeletal manifestations was accompanied by a decrease in laboratory parameters - creatine phosphokinase and CRP. RTX is effective option for treatment of musculoskeletal manifestations in SSc.

Keywords: arthritis, musculoskeletal involvement, systemic sclerosis, rituximab

Procedia PDF Downloads 46
8 The Judiciary as Pacemaker? Considering the Role of Courts in an Expansion of Protection for War Refugees and People Fleeing Natural Disasters

Authors: Charlotte Lülf

Abstract:

Migration flows, resulting from war, climate change or economic crisis cannot be tackled by single states but need to be addressed as a transnational and international responsibility. The traditional architecture surrounding the work of the UNHCR and the 1951 Convention, however, is not equipped to deal with these challenges. Widely excluded from legal protection are people not individually persecuted for the statutory criteria, people that flee from the indiscriminate effects of an armed conflict as well as people fleeing natural disasters. With the lack of explicit legal protection and the political reluctance of nation states worldwide to extend their commitment in new asylum laws, the judiciary must be put in focus: it plays a unique role in interpreting and potentially expanding the application of existing regulations. This paper as part of an ongoing Ph.D. Project deals with the current and partly contradicting approaches to the protection of war- and climate refugees. Changing jurisprudential practice of national and regional courts will be assessed, as will be their dialogue to interpret the international obligations of human rights law, migration laws, and asylum laws in an interacting world. In recent judgments refoulment to an armed conflict as well as countries without adequate disaster relief or health care was argued as violating fundamental human and asylum law rights and therefore prohibited – even for applicants without refugee status: The first step towards access to subsidiary protection could herewith be established. Can one observe similar developments in other parts of the world? This paper will evaluate the role of the judiciary to define, redefine and potentially expand protection for people seeking refuge from armed conflicts and natural disasters.

Keywords: human rights law, asylum-seekers, displacement, migration

Procedia PDF Downloads 242
7 Young Female’s Heart Was Bitten by Unknown Ghost (Isolated Cardiac Sarcoidosis): A Case Report

Authors: Heru Al Amin

Abstract:

Sarcoidosis is a granulomatous inflammatory disorder of unclear etiology that can affect multiple different organ systems. Isolated cardiac sarcoidosis is a very rare condition that causes lethal arrhythmia and heart failure. A definite diagnosis of cardiac sarcoidosis remains challenging. The use of multimodality imaging plays a pivotal role in the diagnosis of this entity. Case summary: In this report, we discuss a case of a 50-year-old woman who presented with recurrent palpitation, dizziness, vertigo and presyncope. Electrocardiogram revealed variable heart blocks, including first-degree AV block, second-degree AV block, high-degree AV block, complete AV block, trifascicular block and sometimes supraventricular arrhythmia. Twenty-four hours of Holter monitoring show atrial bigeminy, first-degree AV block and trifascicular block. Transthoracic echocardiography showed Thinning of basal anteroseptal and inferred septum with LV dilatation with reduction of Global Longitudinal Strain. A dual-chamber pacemaker was implanted. CT Coronary angiogram showed no coronary artery disease. Cardiac magnetic resonance revealed basal anteroseptal and inferior septum thinning with focal edema with LGE suggestive of sarcoidosis. Computed tomography of the chest showed no lymphadenopathy or pulmonary infiltration. 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) of the whole body showed. We started steroids and followed up with the patient. Conclusion: This case serves to highlight the challenges in identifying and managing isolated CS in a young patient with recurrent syncope with variable heart block. Early, even late initiation of steroids can improve arrhythmia as well as left ventricular function.

Keywords: cardiac sarcoidosis, conduction abnormality, syncope, cardiac MRI

Procedia PDF Downloads 52
6 Wharton's Jelly-Derived Mesenchymal Stem Cells Modulate Heart Rate Variability and Improve Baroreflex Sensitivity in Septic Rats

Authors: Cóndor C. José, Rodrigues E. Camila, Noronha L. Irene, Dos Santos Fernando, Irigoyen M. Claudia, Andrade Lúcia

Abstract:

Sepsis induces alterations in hemodynamics and autonomic nervous system (ASN). The autonomic activity can be calculated by measuring heart rate variability (HRV) that represents the complex interplay between ASN and cardiac pacemaker cells. Wharton’s jelly mesenchymal stem cells (WJ-MSCs) are known to express genes and secreted factors involved in neuroprotective and immunological effects, also to improve the survival in experimental septic animals. We hypothesized, that WJ-MSCs present an important role in the autonomic activity and in the hemodynamic effects in a cecal ligation and puncture (CLP) model of sepsis. Methods: We used flow cytometry to evaluate WJ-MSCs phenotypes. We divided Wistar rats into groups: sham (shamoperated); CLP; and CLP+MSC (106 WJ-MSCs, i.p., 6 h after CLP). At 24 h post-CLP, we recorded the systolic arterial pressure (SAP) and heart rate (HR) over 20 min. The spectral analysis of HR and SAP; also the spontaneous baroreflex sensitivity (measure by bradycardic and tachycardic responses) were evaluated after recording. The one-way ANOVA and the post hoc Student– Newman– Keuls tests (P< 0.05) were used to data comparison Results: WJ-MSCs were negative for CD3, CD34, CD45 and HLA-DR, whereas they were positive for CD73, CD90 and CD105. The CLP group showed a reduction in variance of overall variability and in high-frequency power of HR (heart parasympathetic activity); furthermore, there is a low-frequency reduction of SAP (blood vessels sympathetic activity). The treatment with WJ-MSCs improved the autonomic activity by increasing the high and lowfrequency power; and restore the baroreflex sensitive. Conclusions: WJ-MSCs attenuate the impairment of autonomic control of the heart and vessels and might therefore play a protective role in sepsis. (Supported by FAPESP).

Keywords: baroreflex response, heart rate variability, sepsis, wharton’s jelly-derived mesenchymal stem cells

Procedia PDF Downloads 254
5 Informal Carers in Telemonitoring of Users with Pacemakers: Characteristics, Time of Services Provided and Costs

Authors: Antonio Lopez-Villegas, Rafael Bautista-Mesa, Emilio Robles-Musso, Daniel Catalan-Matamoros, Cesar Leal-Costa

Abstract:

Objectives: The purpose of this trial was to evaluate the burden borne by and the costs to informal caregivers of users with telemonitoring of pacemakers. Methods: This is a controlled, non-randomised clinical trial, with data collected from informal caregivers, five years after implantation of pacemakers. The Spanish version of the Survey on Disabilities, Personal Autonomy, and Dependency Situations was used to get information on clinical and social characteristics, levels of professionalism, duration and types of care, difficulties in providing care, health status, economic and job aspects, impact on the family or leisure due to informal caregiving for patients with pacemakers. Results: After five years of follow-up, 55 users with pacemakers finished the study. Of which, 50 were helped by a caregiver, 18 were included in the telemonitoring group (TM) and 32 in the conventional follow-up group (HM). Overall, females represented 96.0% of the informal caregivers (88.89% in TM and 100.0% in HM group). The mean ages were 63.17 ± 15.92 and 63.13 ± 14.56 years, respectively (p = 0.83) in the groups. The majority (88.0%) of the caregivers declared that they had to provide their services between 6 and 7 days per week (83.33% in TM group versus 90.63% in HM group), without significant differences between both groups. The costs related to care provided by the informal caregivers were 47.04% higher in the conventional follow-up group than in the TM group. Conclusions: The results of this trial confirm that there were no significant differences between the informal caregivers regarding to baseline characteristics, workload and time worked in both groups of follow-up. The costs incurred by the informal caregivers providing care for users with pacemakers included in telemonitoring group are significantly lower than those in the conventional follow-up group. Trial registration: ClinicalTrials.gov NCT02234245. Funding: The PONIENTE study, has been funded by the General Secretariat for Research, Development and Innovation, Regional Government of Andalusia (Spain), project reference number PI/0256/2017, under the research call 'Development and Innovation Projects in the Field of Biomedicine and Health Sciences', 2017.

Keywords: costs, disease burden, informal caregiving, pacemaker follow-up, remote monitoring, telemedicine

Procedia PDF Downloads 102
4 Measurements for Risk Analysis and Detecting Hazards by Active Wearables

Authors: Werner Grommes

Abstract:

Intelligent wearables (illuminated vests or hand and foot-bands, smart watches with a laser diode, Bluetooth smart glasses) overflow the market today. They are integrated with complex electronics and are worn very close to the body. Optical measurements and limitation of the maximum light density are needed. Smart watches are equipped with a laser diode or control different body currents. Special glasses generate readable text information that is received via radio transmission. Small high-performance batteries (lithium-ion/polymer) supply the electronics. All these products have been tested and evaluated for risk. These products must, for example, meet the requirements for electromagnetic compatibility as well as the requirements for electromagnetic fields affecting humans or implant wearers. Extensive analyses and measurements were carried out for this purpose. Many users are not aware of these risks. The result of this study should serve as a suggestion to do it better in the future or simply to point out these risks. Commercial LED warning vests, LED hand and foot-bands, illuminated surfaces with inverter (high voltage), flashlights, smart watches, and Bluetooth smart glasses were checked for risks. The luminance, the electromagnetic emissions in the low-frequency as well as in the high-frequency range, audible noises, and nervous flashing frequencies were checked by measurements and analyzed. Rechargeable lithium-ion or lithium-polymer batteries can burn or explode under special conditions like overheating, overcharging, deep discharge or using out of the temperature specification. Some risk analysis becomes necessary. The result of this study is that many smart wearables are worn very close to the body, and an extensive risk analysis becomes necessary. Wearers of active implants like a pacemaker or implantable cardiac defibrillator must be considered. If the wearable electronics include switching regulators or inverter circuits, active medical implants in the near field can be disturbed. A risk analysis is necessary.

Keywords: safety and hazards, electrical safety, EMC, EMF, active medical implants, optical radiation, illuminated warning vest, electric luminescent, hand and head lamps, LED, e-light, safety batteries, light density, optical glare effects

Procedia PDF Downloads 76
3 A Review of Brain Implant Device: Current Developments and Applications

Authors: Ardiansyah I. Ryan, Ashsholih K. R., Fathurrohman G. R., Kurniadi M. R., Huda P. A

Abstract:

The burden of brain-related disease is very high. There are a lot of brain-related diseases with limited treatment result and thus raise the burden more. The Parkinson Disease (PD), Mental Health Problem, or Paralysis of extremities treatments had risen concern, as the patients for those diseases usually had a low quality of life and low chance to recover fully. There are also many other brain or related neural diseases with the similar condition, mainly the treatments for those conditions are still limited as our understanding of the brain function is insufficient. Brain Implant Technology had given hope to help in treating this condition. In this paper, we examine the current update of the brain implant technology. Neurotechnology is growing very rapidly worldwide. The United States Food and Drug Administration (FDA) has approved the use of Deep Brain Stimulation (DBS) as a brain implant in humans. As for neural implant both the cochlear implant and retinal implant are approved by FDA too. All of them had shown a promising result. DBS worked by stimulating a specific region in the brain with electricity. This device is planted surgically into a very specific region of the brain. This device consists of 3 main parts: Lead (thin wire inserted into the brain), neurostimulator (pacemaker-like device, planted surgically in the chest) and an external controller (to turn on/off the device by patient/programmer). FDA had approved DBS for the treatment of PD, Pain Management, Epilepsy and Obsessive Compulsive Disorder (OCD). The target treatment of DBS in PD is to reduce the tremor and dystonia symptoms. DBS has been showing the promising result in animal and limited human trial for other conditions such as Alzheimer, Mental Health Problem (Major Depression, Tourette Syndrome), etc. Every surgery has risks of complications, although in DBS the chance is very low. DBS itself had a very satisfying result as long as the subject criteria to be implanted this device based on indication and strictly selection. Other than DBS, there are several brain implant devices that still under development. It was included (not limited to) implant to treat paralysis (In Spinal Cord Injury/Amyotrophic Lateral Sclerosis), enhance brain memory, reduce obesity, treat mental health problem and treat epilepsy. The potential of neurotechnology is unlimited. When brain function and brain implant were fully developed, it may be one of the major breakthroughs in human history like when human find ‘fire’ for the first time. Support from every sector for further research is very needed to develop and unveil the true potential of this technology.

Keywords: brain implant, deep brain stimulation (DBS), deep brain stimulation, Parkinson

Procedia PDF Downloads 114
2 Finding the Association Rule between Nursing Interventions and Early Evaluation Results of In-Hospital Cardiac Arrest to Improve Patient Safety

Authors: Wei-Chih Huang, Pei-Lung Chung, Ching-Heng Lin, Hsuan-Chia Yang, Der-Ming Liou

Abstract:

Background: In-Hospital Cardiac Arrest (IHCA) threaten life of the inpatients, cause serious effect to patient safety, quality of inpatients care and hospital service. Health providers must identify the signs of IHCA early to avoid the occurrence of IHCA. This study will consider the potential association between early signs of IHCA and the essence of patient care provided by nurses and other professionals before an IHCA occurs. The aim of this study is to identify significant associations between nursing interventions and abnormal early evaluation results of IHCA that can assist health care providers in monitoring inpatients at risk of IHCA to increase opportunities of IHCA early detection and prevention. Materials and Methods: This study used one of the data mining techniques called association rules mining to compute associations between nursing interventions and abnormal early evaluation results of IHCA. The nursing interventions and abnormal early evaluation results of IHCA were considered to be co-occurring if nursing interventions were provided within 24 hours of last being observed in abnormal early evaluation results of IHCA. The rule based methods were utilized 23.6 million electronic medical records (EMR) from a medical center in Taipei, Taiwan. This dataset includes 733 concepts of nursing interventions that coded by clinical care classification (CCC) codes and 13 early evaluation results of IHCA with binary codes. The values of interestingness and lift were computed as Q values to measure the co-occurrence and associations’ strength between all in-hospital patient care measures and abnormal early evaluation results of IHCA. The associations were evaluated by comparing the results of Q values and verified by medical experts. Results and Conclusions: The results show that there are 4195 pairs of associations between nursing interventions and abnormal early evaluation results of IHCA with their Q values. The indication of positive association is 203 pairs with Q values greater than 5. Inpatients with high blood sugar level (hyperglycemia) have positive association with having heart rate lower than 50 beats per minute or higher than 120 beats per minute, Q value is 6.636. Inpatients with temporary pacemaker (TPM) have significant association with high risk of IHCA, Q value is 47.403. There is significant positive correlation between inpatients with hypovolemia and happened abnormal heart rhythms (arrhythmias), Q value is 127.49. The results of this study can help to prevent IHCA from occurring by making health care providers early recognition of inpatients at risk of IHCA, assist with monitoring patients for providing quality of care to patients, improve IHCA surveillance and quality of in-hospital care.

Keywords: in-hospital cardiac arrest, patient safety, nursing intervention, association rule mining

Procedia PDF Downloads 236
1 Complex Dynamics in a Morphologically Heterogeneous Biological Medium

Authors: Turky Al-Qahtani, Roustem Miftahof

Abstract:

Introduction: Under common assumptions of excitabi-lity, morphological (cellular) homogeneity, and spatial structural anomalies added as required, it has been shown that biological systems are able to display travelling wave dynamics. Being not self-sustainable, existence depends on the electrophysiological state of transmembrane ion channels and it requires an extrinsic/intrinsic periodic source. However, organs in the body are highly multicellular, heterogeneous, and their functionality is the outcome of electro-mechanical conjugation, rather than excitability only. Thus, peristalsis in the gut relies on spatiotemporal myoelectrical pattern formations between the mechanical, represented by smooth muscle cells (SM), and the control, comprised of a chain of primary sensory and motor neurones, components. Synaptically linked through the afferent and efferent pathways, they form a functional unit (FU) of the gut. Aims: These are: i) to study numerically the complex dynamics, and ii) to investigate the possibility of self-sustained myoelectrical activity in the FU. Methods: The FU recreates the following sequence of physiological events: deformation of mechanoreceptors of located in SM; generation and propagation of electrical waves of depolarisation - spikes - along the axon to the soma of the primary neurone; discharge of the primary neurone and spike propagation towards the motor neurone; burst of the motor neurone and transduction of spikes to SM, subsequently producing forces of contraction. These are governed by a system of nonlinear partial and ordinary differential equations being a modified version of the Hodgkin-Huxley model and SM fibre mechanics. In numerical experiments; the source of excitation is mechanical stretches of SM at a fixed amplitude and variable frequencies. Results: Low frequency (0.5 < v < 2 Hz) stimuli cause the propagation of spikes in the neuronal chain and, finally, the generation of active forces by SM. However, induced contractions are not sufficient to initiate travelling wave dynamics in the control system. At frequencies, 2 < v < 4 Hz, multiple low amplitude and short-lasting contractions are observed in SM after the termination of stretching. For frequencies (0.5 < v < 4 Hz), primary and sensory neurones demonstrate strong connectivity and coherent electrical activity. Significant qualitative and quantitative changes in dynamics of myoelectical patterns with a transition to a self-organised mode are recorded with the high degree of stretches at v = 4.5 Hz. Increased rates of deformation lead to the production of high amplitude signals at the mechanoreceptors with subsequent self-sustained excitation within the neuronal chain. Remarkably, the connection between neurones weakens resulting in incoherent firing. Further increase in a frequency of stimulation (v > 4.5 Hz) has a detrimental effect on the system. The mechanical and control systems become disconnected and exhibit uncoordinated electromechanical activity. Conclusion: To our knowledge, the existence of periodic activity in a multicellular, functionally heterogeneous biological system with mechano-electrical dynamics, such as the FU, has been demonstrated for the first time. These findings support the notion of possible peristalsis in the gut even in the absence of intrinsic sources - pacemaker cells. Results could be implicated in the pathogenesis of intestinal dysrythmia, a medical condition associated with motor dysfunction.

Keywords: complex dynamics, functional unit, the gut, dysrythmia

Procedia PDF Downloads 169