Search results for: low dose spinal
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1528

Search results for: low dose spinal

1378 A Systematic Review of Efficacy and Safety of Radiofrequency Ablation in Patients with Spinal Metastases

Authors: Pascale Brasseur, Binu Gurung, Nicholas Halfpenny, James Eaton

Abstract:

Development of minimally invasive treatments in recent years provides a potential alternative to invasive surgical interventions which are of limited value to patients with spinal metastases due to short life expectancy. A systematic review was conducted to explore the efficacy and safety of radiofrequency ablation (RFA), a minimally invasive treatment in patients with spinal metastases. EMBASE, Medline and CENTRAL were searched from database inception to March 2017 for randomised controlled trials (RCTs) and non-randomised studies. Conference proceedings for ASCO and ESMO published in 2015 and 2016 were also searched. Fourteen studies were included: three prospective interventional studies, four prospective case series and seven retrospective case series. No RCTs or studies comparing RFA with another treatment were identified. RFA was followed by cement augmentation in all patients in seven studies and some patients (40-96%) in the remaining seven studies. Efficacy was assessed as pain relief in 13/14 studies with the use of a numerical rating scale (NRS) or a visual analogue scale (VAS) at various time points. Ten of the 13 studies reported a significant decrease in pain outcome, post-RFA compared to baseline. NRS scores improved significantly at 1 week (5.9 to 3.5, p < 0.0001; 8 to 4.3, p < 0.02 and 8 to 3.9, p < 0.0001) and this improvement was maintained at 1 month post-RFA compared to baseline (5.9 to 2.6, p < 0.0001; 8 to 2.9, p < 0.0003; 8 to 2.9, p < 0.0001). Similarly, VAS scores decreased significantly at 1 week (7.5 to 2.7, p=0.00005; 7.51 to 1.73, p < 0.0001; 7.82 to 2.82, p < 0.001) and this pattern was maintained at 1 month post-RFA compared to baseline (7.51 to 2.25, p < 0.0001; 7.82 to 3.3; p < 0.001). A significant pain relief was achieved regardless of whether patients had cement augmentation in two studies assessing the impact of RFA with or without cement augmentation on VAS pain scores. In these two studies, a significant decrease in pain scores was reported for patients receiving RFA alone and RFA+cement at 1 week (4.3 to 1.7. p=0.0004 and 6.6 to 1.7, p=0.003 respectively) and 15-36 months (7.9 to 4, p=0.008 and 7.6 to 3.5, p=0.005 respectively) after therapy. Few minor complications were reported and these included neural damage, radicular pain, vertebroplasty leakage and lower limb pain/numbness. In conclusion, the efficacy and safety of RFA were consistently positive between prospective and retrospective studies with reductions in pain and few procedural complications. However, the lack of control groups in the identified studies indicates the possibility of selection bias inherent in single arm studies. Controlled trials exploring efficacy and safety of RFA in patients with spinal metastases are warranted to provide robust evidence. The identified studies provide an initial foundation for such future trials.

Keywords: pain relief, radiofrequency ablation, spinal metastases, systematic review

Procedia PDF Downloads 138
1377 Dosimetric Application of α-Al2O3:C for Food Irradiation Using TA-OSL

Authors: A. Soni, D. R. Mishra, D. K. Koul

Abstract:

α-Al2O3:C has been reported to have deeper traps at 600°C and 900°C respectively. These traps have been reported to accessed at relatively earlier temperatures (122 and 322 °C respectively) using thermally assisted OSL (TA-OSL). In this work, the dose response α-Al2O3:C was studied in the dose range of 10Gy to 10kGy for its application in food irradiation in low ( upto 1kGy) and medium(1 to 10kGy) dose range. The TOL (Thermo-optically stimulated luminescence) measurements were carried out on RisØ TL/OSL, TL-DA-15 system having a blue light-emitting diodes (λ=470 ±30nm) stimulation source with power level set at the 90% of the maximum stimulation intensity for the blue LEDs (40 mW/cm2). The observations were carried on commercial α-Al2O3:C phosphor. The TOL experiments were carried out with number of active channel (300) and inactive channel (1). Using these settings, the sample is subjected to linear thermal heating and constant optical stimulation. The detection filter used in all observations was a Hoya U-340 (Ip ~ 340 nm, FWHM ~ 80 nm). Irradiation of the samples was carried out using a 90Sr/90Y β-source housed in the system. A heating rate of 2 °C/s was preferred in TL measurements so as to reduce the temperature lag between the heater plate and the samples. To study the dose response of deep traps of α-Al2O3:C, samples were irradiated with various dose ranging from 10 Gy to 10 kGy. For each set of dose, three samples were irradiated. In order to record the TA-OSL, initially TL was recorded up to a temperature of 400°C, to deplete the signal due to 185°C main dosimetry TL peak in α-Al2O3:C, which is also associated with the basic OSL traps. After taking TL readout, the sample was subsequently subjected to TOL measurement. As a result, two well-defined TA-OSL peaks at 121°C and at 232°C occur in time as well as temperature domain which are different from the main dosimetric TL peak which occurs at ~ 185°C. The linearity of the integrated TOL signal has been measured as a function of absorbed dose and found to be linear upto 10kGy. Thus, it can be used for low and intermediate dose range of for its application in food irradiation. The deep energy level defects of α-Al2O3:C phosphor can be accessed using TOL section of RisØ reader system.

Keywords: α-Al2O3:C, deep traps, food irradiation, TA-OSL

Procedia PDF Downloads 259
1376 Optimizing Exposure Parameters in Digital Mammography: A Study in Morocco

Authors: Talbi Mohammed, Oustous Aziz, Ben Messaoud Mounir, Sebihi Rajaa, Khalis Mohammed

Abstract:

Background: Breast cancer is the leading cause of death for women around the world. Screening mammography is the reference examination, due to its sensitivity for detecting small lesions and micro-calcifications. Therefore, it is essential to ensure quality mammographic examinations with the most optimal dose. These conditions depend on the choice of exposure parameters. Clinically, practices must be evaluated in order to determine the most appropriate exposure parameters. Material and Methods: We performed our measurements on a mobile mammography unit (PLANMED Sofie-classic.) in Morocco. A solid dosimeter (AGMS Radcal) and a MTM 100 phantom allow to quantify the delivered dose and the image quality. For image quality assessment, scores are defined by the rate of visible inserts (MTM 100 phantom), obtained and compared for each acquisition. Results: The results show that the parameters of the mammography unit on which we have made our measurements can be improved in order to offer a better compromise between image quality and breast dose. The last one can be reduced up from 13.27% to 22.16%, while preserving comparable image quality.

Keywords: Mammography, Breast Dose, Image Quality, Phantom

Procedia PDF Downloads 127
1375 Influence of Pediococcus Pentasaceus Isolate “Dadih” (Buffalo Milk Fermended in Bamboo) the Bowel Frequence, Secretory Immunoglobulin a Level and Height of Ileum Villi of the Mice EPEC Induced Diarrhea

Authors: Endang Purwati Rahayuningsih

Abstract:

The aim of this study is Enteropathogenic Eschericia coli O157 (EPEC) is one of the pathogen that can cause inflamation and damage intestinal mucosa, which is leading diarrhea. Inflamation in the intestinal mucosa proved by the presence of secretory Immunoglobulin A (sIgA) on the feces. Isolate dadih is Pediococcus pentosaceus (P. pentosaceus) as a probiotic lactic acid bacteria (LAB) is very usefull to improve sIgA and intestinal mucosa. The objective, to determine the dose and duration administration of P. pentosaceus for bowel frequence, sIgA level and height of illeum villi in mice EPEC-induced diarrhea. Method, using Complete Randomized design studies in mice EPEC-induced diarrhea. Mice was classified into 2 factors. A factor (dose of probiotic) and B factor (duration of probiotic observation) consisted of 0 hour, 12 hours, 24 hours and 36 hours. A factor consisted of negative control, positive control (mice induced by EPEC) and 3 different dose experimental mice. The results were a very significant interaction between dose and duration administration of P. pentosaceus. Mean of the most frequent defecation of mice EPEC-induced was 55 graetly reduced into 12 ,after 24 hours administration P. pentosaceus dose 2 x 1010 cfu/g, Mean of sIgA level of mice induced EPEC was 1,60 μg/ml, very significant different (p<0,01). Mean of sIgA level after 24 administration P. pentosaceus dose 2 x 1010cfu/g was 2,65 μg/ml. Mean of height of illeum villi after induced EPEC 53,04 μm with very significant different after 24 hours administration P. pentosaceus dose 2 x 1010cfu/g (142,881μm). This study concluded that P. pentosaceus dose 2 x 1010cfu/g after 24 hours is very beneficial to reduced bowel frequence, increase sIgA level and improve the height illeum villi of mice EPEC-induced diarrhea.

Keywords: Pediococcus pentosaceus, sIgA, enteropathogenic Eschericia coli O157, diarrhea, illeum villi

Procedia PDF Downloads 425
1374 Dosimetric Comparison of Conventional Optimization Methods with Inverse Planning Simulated Annealing Technique

Authors: Shraddha Srivastava, N. K. Painuly, S. P. Mishra, Navin Singh, Muhsin Punchankandy, Kirti Srivastava, M. L. B. Bhatt

Abstract:

Various optimization methods used in interstitial brachytherapy are based on dwell positions and dwell weights alteration to produce dose distribution based on the implant geometry. Since these optimization schemes are not anatomy based, they could lead to deviations from the desired plan. This study was henceforth carried out to compare anatomy-based Inverse Planning Simulated Annealing (IPSA) optimization technique with graphical and geometrical optimization methods in interstitial high dose rate brachytherapy planning of cervical carcinoma. Six patients with 12 CT data sets of MUPIT implants in HDR brachytherapy of cervical cancer were prospectively studied. HR-CTV and organs at risk (OARs) were contoured in Oncentra treatment planning system (TPS) using GYN GEC-ESTRO guidelines on cervical carcinoma. Three sets of plans were generated for each fraction using IPSA, graphical optimization (GrOPT) and geometrical optimization (GOPT) methods. All patients were treated to a dose of 20 Gy in 2 fractions. The main objective was to cover at least 95% of HR-CTV with 100% of the prescribed dose (V100 ≥ 95% of HR-CTV). IPSA, GrOPT, and GOPT based plans were compared in terms of target coverage, OAR doses, homogeneity index (HI) and conformity index (COIN) using dose-volume histogram (DVH). Target volume coverage (mean V100) was found to be 93.980.87%, 91.341.02% and 85.052.84% for IPSA, GrOPT and GOPT plans respectively. Mean D90 (minimum dose received by 90% of HR-CTV) values for IPSA, GrOPT and GOPT plans were 10.19 ± 1.07 Gy, 10.17 ± 0.12 Gy and 7.99 ± 1.0 Gy respectively, while D100 (minimum dose received by 100% volume of HR-CTV) for IPSA, GrOPT and GOPT plans was 6.55 ± 0.85 Gy, 6.55 ± 0.65 Gy, 4.73 ± 0.14 Gy respectively. IPSA plans resulted in lower doses to the bladder (D₂

Keywords: cervical cancer, HDR brachytherapy, IPSA, MUPIT

Procedia PDF Downloads 145
1373 Gamma Irradiation Effects on the Magnetic Properties of Hard Ferrites

Authors: F. Abbas Pour Khotbehsara, B. Salehpour, A. Kianvash

Abstract:

Many industrial materials like magnets need to be tested for the radiation environment expected at linear colliders (LC) where the accelerator and detectors will be subjected to large influences of beta, neutron and gamma’s over their life Gamma irradiation of the permanent sample magnets using a 60Co source was investigated up to an absorbed dose of 700Mrad shows a negligible effect on some magnetic properties of Nd-Fe-B. In this work, it has been tried to investigate the change of some important properties of Barium hexa ferrite. Results showed little decreases of magnetic properties at doses rang of 0.5 to 2.5 Mrad. But at the gamma irradiation dose up to 10 Mrad it is showed a few increase of properties. Also study of gamma irradiation of Nd-Fe-B showed considerably increase of magnetic properties.

Keywords: gamma ray irradiation, hard ferrite, magnetic coefficient, magnetic material, radiation dose

Procedia PDF Downloads 205
1372 Assessment of Dose: Area Product of Common Radiographic Examinations in Selected Southern Nigerian Hospitals

Authors: Lateef Bamidele

Abstract:

Over the years, radiographic examinations are the most used diagnostic tools in the Nigerian health care system, but most diagnostic examinations carried out do not have records of patient doses. Lack of adequate information on patient doses has been a major hindrance in quantifying the radiological risk associated with radiographic examinations. This study aimed at estimating dose–area product (DAP) of patient examined in X-Ray units in selected hospitals in Southern Nigeria. The standard projections selected are chest posterior-anterior (PA), abdomen anterior-posterior (AP), pelvis AP, pelvis lateral (LAT), skull AP/PA, skull LAT, lumbar spine AP, lumbar spine, LAT. Measurement of entrance surface dose (ESD) was carried out using thermoluminescent dosimeter (TLD). Measured ESDs were converted into DAP using the beam area of patients. The results show that the mean DAP ranged from 0.17 to 18.35 Gycm². The results obtained in this study when compared with those of NRPB-HPE were found to be higher. These are an indication of non optimization of operational conditions.

Keywords: dose–area product, radiographic examinations, patient doses, optimization

Procedia PDF Downloads 140
1371 A Reminder of a Rare Anatomical Variant of the Spinal Accessory Nerve Encountered During Routine Neck Dissection: A Case Report and Updated Review of the Literature

Authors: Sophie Mills, Constantinos Aristotelous, Leila L. Touil, Richard C. W. James

Abstract:

Objectives: Historical studies of the anatomy of the spinal accessory nerve (SAN) have reported conflicting results regarding its relationship with the internal jugular vein (IJV). A literature review was undertaken to establish the prevalence of anatomical variations of the SAN encountered during routine neck dissection surgery in order to increase awareness and reduce morbidity associated with iatrogenic SAN injury. Materials and Methods: The largest systematic review to date was performed using PRISMA-ScR guidelines, which yielded nine articles following the application of inclusion and exclusion criteria. A case report is also included, which demonstrates the rare anatomical relationship of the SAN traversing a fenestrated IJV, seen for the first time in the senior author’s career. Results: The mean number of dissections per study was 119, of which 55.6% (n=5) studies were performed on cadaver subjects, and 44.4% (n=4) were surgical dissections. Incidences of the SAN lateral to the IJV and medial to the IJV ranged from 38.9%-95.7% and 2.8%-57.4%, respectively. Over half of the studies reported incidences of the SAN traversing the IJV in 0.9%-2.8% of dissections. One study reported an isolated variant of the SAN dividing around the IJV with a prevalence of 0.5%. Conclusion: At the level of the posterior belly of the digastric muscle, the surgeon can anticipate the identification of the SAN lateral to the IJV in approximately three-quarters of cases, whilst around one-quarter are estimated to be medial. A mean of 1.6% of SANs traverses a fenestration of the vein. It is essential for surgeons to be aware of these anatomical variations and their prevalence to prevent injury to vital structures during surgery.

Keywords: anatomical variant, internal jugular vein, neck dissection, spinal accessory nerve

Procedia PDF Downloads 99
1370 Abnormal Branching Pattern of Lumbar Plexus in an Adult Male Cadaver: A Case Report

Authors: Deepthinath Reghunathan, Satheesha Nayak, Sudarshan S., Prasad Alathady Maloor, Prakash Shetty

Abstract:

Lumbar plexus is formed by the union of ventral rami of T12, L1, L2, L3 spinal nerves and the larger upper division of L4 lumbar spinal nerves. Variations in the normal anatomy of the lumbar and sacral plexus might be seen in some cases and are reported in the literature, but finding such an unusual case comprising of multiple variations which is normally not expected in a clinical setup, proves to be a vital piece of information for clinicians and medical practitioners. During the dissection of the abdomen and pelvis of an approximately 70 year old cadaver, we observed the following variations in the formation of the lumbar and sacral nerves. 1. The genitofemoral nerve bifurcated at a higher level; genital branch of genitofemoral nerve gave branches to the anterior abdominal wall muscles, 2. A communicating branch was given from the lateral cutaneous nerve of thigh to the medial cutaneous nerve of thigh, 3. A muscular branch was given from femoral nerve to psoas major, 4. There was absence of contribution of L4 spinal nerve in the formation of the lumbosacral trunk and 5. Lumbosacral trunk gave communicating branches to the femoral and obturator nerves. Most of the variations found were rare and finding all the above said variations in a single cadaver is even rare. Documentation of such rare cases with multiple variations in the formation of nerves from the lumbar plexus provides vital information on such occurrences. This information would in turn improve the knowledge of clinicians and surgeons dealing with this region. Emphasizing such knowledge of this region would prevent accidental damage to the structures with a variant anatomy.

Keywords: femoral nerve, genitofemoral nerve, lumbar plexus, lumbosacral trunk

Procedia PDF Downloads 244
1369 Low-Dose Chest Computed Tomography Can Help in Differential Diagnosis of Asthma–COPD Overlap Syndrome in Children

Authors: Frantisek Kopriva, Kamila Michalkova, Radim Dudek, Jana Volejnikova

Abstract:

Rationale: Diagnostic criteria of asthma–COPD overlap syndrome (ACOS) are controversial in pediatrics. Emphysema is characteristic of COPD and usually does not occur in typical asthma; its presence in patients with asthma suggests the concurrence with COPD. Low-dose chest computed tomography (CT) allows a non-invasive assessment of the lung tissue structure. Here we present CT findings of emphysematous changes in a child with ACOS. Patient and Methods: In a 6-year-old boy, atopy was confirmed by a skin prick test using common allergen extracts (grass and tree pollen, house dust mite, molds, cat, dog; manufacturer Stallergenes Greer, London, UK), where reactions over 3 mm were considered positive. Treatment with corticosteroids was started during the course of severe asthma. At 12 years of age, his spirometric parameters deteriorated despite treatment adjustment (VC 1.76 L=85%, FEV1 1.13 L=67%, TI%VCmax 64%, MEF25 19%, TLC 144%) and the bronchodilator test became negative. Results: Low-dose chest CT displayed irregular regions with increased radiolucency of pulmonary parenchyma (typical for hyperinflation in emphysematous changes) in both lungs. This was in accordance with the results of spirometric examination. Conclusions: ACOS is infrequent in children. However, low-dose chest CT scan can be considered to confirm this diagnosis or eliminate other diagnoses when the clinical condition is deteriorating and treatment response is poor.

Keywords: child, asthma, low-dose chest CT, ACOS

Procedia PDF Downloads 109
1368 How Geant4 Hadronic Models Handle Tracking of Pion Particles Resulting from Antiproton Annihilation

Authors: M. B. Tavakoli, R. Reiazi, M. M. Mohammadi, K. Jabbari

Abstract:

From 2003, AD4/ACE experiment in CERN tried to investigate different aspects of antiproton as a new modality in particle therapy. Because of lack of reliable absolute dose measurements attempts to find out the radiobiological characteristics of antiproton have not reached to a reasonable result yet. From the other side, application of Geant4 in medical approaches is increased followed by Geant4-DNA project which focuses on using this code to predict radiation effects in the cellular scale. This way we can exploit Geant4-DNA results for antiproton. Unfortunately, previous studies showed there are serious problem in simulating an antiproton beam using Geant4. Since most of the problem was in the Bragg peak region which antiproton annihilates there, in this work we tried to understand if the problem came from the way in which Geant4 handles annihilation products especially pion particles. This way, we can predict the source of the dose discrepancies between Geant4 simulations and dose measurements done in CERN.

Keywords: Geant4, antiproton, annihilation, pion plus, pion minus

Procedia PDF Downloads 621
1367 Toxicities associated with EBRT and Brachytherapy for Intermediate and High Risk Prostate Cancer, Correlated with Intra-operative Dosing

Authors: Rebecca Dunne, Cormac Small, Geraldine O'Boyle, Nazir Ibrahim, Anisha

Abstract:

Prostate cancer is the most common cancer among men, excluding non-melanoma skin cancers. It is estimated that approximately 12% of men will develop prostate cancer during their lifetime. Patients with intermediate, high risk, and very-high risk prostate cancer often undergo a combination of radiation treatments. These treatments include external beam radiotherapy with a low-dose rate or high-dose rate brachytherapy boost, often with concomitant androgen deprivation therapy. The literature on follow-up of patients that receive brachytherapy is scarce, particularly follow-up of patients that undergo high-dose rate brachytherapy. This retrospective study aims to investigate the biochemical failure and toxicities associated with triple therapy and external beam radiotherapy given in combination with brachytherapy. Reported toxicities and prostate specific antigen (PSA) were retrospectively evaluated in eighty patients that previously underwent external beam radiotherapy with a low-dose rate or high dose-rate brachytherapy boost. The severity of toxicities were correlated with intra-operative dosing during brachytherapy on ultrasound and CT scan. The results of this study will provide further information for clinicians and patients when considering treatment options.

Keywords: toxicities, combination, brachytherapy, intra-operative dosing, biochemical failure

Procedia PDF Downloads 186
1366 Optimizing the Doses of Chitosan/Tripolyphosphate Loaded Nanoparticles of Clodinofop Propargyl and Fenoxaprop-P-Ethyl to Manage Avena Fatua L.: An Environmentally Safer Alternative to Control Weeds

Authors: Muhammad Ather Nadeem, Bilal Ahmad Khan, Hussam F. Najeeb Alawadi, Athar Mahmood, Aneela Nijabat, Tasawer Abbas, Muhammad Habib, Abdullah

Abstract:

The global prevalence of Avena fatua infestation poses a significant challenge to wheat sustainability. While chemical control stands out as an efficient and rapid way to control weeds, concerns over developing resistance in weeds and environmental pollution have led to criticisms of herbicide use. Consequently, this study was designed to address these challenges through the chemical synthesis, characterization, and optimization of chitosan-based nanoparticles containing clodinofop Propargyl and fenoxaprop-P-ethyl for the effective management of A. fatua. Utilizing the ionic gelification technique, chitosan-based nanoparticles of clodinofop Propargyl and fenoxaprop-P-ethyl were prepared. These nanoparticles were applied at the 3-4 leaf stage of Phalaris minor weed, applying seven altered doses. These nanoparticles were applied at the 3-4 leaf stage of Phalaris minor weed, applying seven altered doses (D0 (Check weeds), D1 (Recommended dose of traditional-herbicide (TH), D2 (Recommended dose of Nano-herbicide (NPs-H)), D3 (NPs-H with 05-fold lower dose), D4 ((NPs-H) with 10-fold lower dose), D5 (NPs-H with 15-fold lower dose), and D6 (NPs-H with 20-fold lower dose)). Characterization of the chitosan-containing herbicide nanoparticles (CHT-NPs) was conducted using FT-IR analysis, demonstrating a perfect match with standard parameters. UV–visible spectrum further revealed absorption peaks at 310 nm for NPs of clodinofop propargyl and at 330 nm for NPs of fenoxaprop-p-ethyl. This research aims to contribute to sustainable weed management practices by addressing the challenges associated with chemical herbicide use. The application of chitosan-based nanoparticles (CHT-NPs) containing fenoxaprop-P-ethyl and clodinofop-propargyl at the recommended dose of the standard herbicide resulted in 100% mortality and visible injury to weeds. Surprisingly, when applied at a lower dose with 5-folds, these chitosan-containing nanoparticles of clodinofop Propargyl and fenoxaprop-P-ethyl demonstrated extreme control efficacy. Furthermore, at a 10-fold lower dose compared to standard herbicides and the recommended dose of clodinofop-propargyl and fenoxaprop-P-ethyl, the chitosan-based nanoparticles exhibited comparable effects on chlorophyll content, visual injury (%), mortality (%), plant height (cm), fresh weight (g), and dry weight (g) of A. fatua. This study indicates that chitosan/tripolyphosphate-loaded nanoparticles containing clodinofop-propargyl and fenoxaprop-P-ethyl can be effectively utilized for the management of A. fatua at a 10-fold lower dose, highlighting their potential for sustainable and efficient weed control.

Keywords: mortality, chitosan-based nanoparticles, visual injury, chlorophyl contents, 5-fold lower dose.

Procedia PDF Downloads 6
1365 Measurement of 238U, 232Th and 40K in Soil Samples Collected from Coal City Dhanbad, India

Authors: Zubair Ahmad

Abstract:

Specific activities of the natural radionuclides 238U, 232Th and 40K were measured by using γ - ray spectrometric technique in soil samples collected from the city of Dhanbad, which is located near coal mines. Mean activity values for 238U, 232Th and 40K were found to be 60.29 Bq/kg, 64.50 Bq/kg and 481.0 Bq/kg, respectively. Mean radium equivalent activity, absorbed dose rate, outdoor dose, external hazard index, internal hazard index, for the area under study were determined as 189.53 Bq/kg, 87.21 nGy/h, 0.37 mSv/y, 0.52 and 0.64, respectively. The annual effective dose to the general public was found 0.44 mSv/y. This value lies well below the limit of 1 mSv/y as recommended by International Commission on Radiological Protection. Measured values were found safe for environment and public health.

Keywords: coal city Dhanbad, gamma-ray spectroscopy, natural radioactivity, soil samples

Procedia PDF Downloads 229
1364 Increasing Access to Upper Limb Reconstruction in Cervical Spinal Cord Injury

Authors: Michelle Jennett, Jana Dengler, Maytal Perlman

Abstract:

Background: Cervical spinal cord injury (SCI) is a devastating event that results in upper limb paralysis, loss of independence, and disability. People living with cervical SCI have identified improvement of upper limb function as a top priority. Nerve and tendon transfer surgery has successfully restored upper limb function in cervical SCI but is not universally used or available to all eligible individuals. This exploratory mixed-methods study used an implementation science approach to better understand these factors that influence access to upper limb reconstruction in the Canadian context and design an intervention to increase access to care. Methods: Data from the Canadian Institute for Health Information’s Discharge Abstracts Database (CIHI-DAD) and the National Ambulatory Care Reporting System (NACRS) were used to determine the annual rate of nerve transfer and tendon transfer surgeries performed in cervical SCI in Canada over the last 15 years. Semi-structured interviews informed by the consolidated framework for implementation research (CFIR) were used to explore Ontario healthcare provider knowledge and practices around upper limb reconstruction. An inductive, iterative constant comparative process involving descriptive and interpretive analyses was used to identify themes that emerged from the data. Results: Healthcare providers (n = 10 upper extremity surgeons, n = 10 SCI physiatrists, n = 12 physical and occupational therapists working with individuals with SCI) were interviewed about their knowledge and perceptions of upper limb reconstruction and their current practices and discussions around upper limb reconstruction. Data analysis is currently underway and will be presented. Regional variation in rates of upper limb reconstruction and trends over time are also currently being analyzed. Conclusions: Utilization of nerve and tendon transfer surgery to improve upper limb reconstruction in Canada remains low. There are a complex array of interrelated individual-, provider- and system-level barriers that prevent individuals with cervical SCI from accessing upper limb reconstruction. In order to offer equitable access to care, a multi-modal approach addressing current barriers is required.

Keywords: cervical spinal cord injury, nerve and tendon transfer surgery, spinal cord injury, upper extremity reconstruction

Procedia PDF Downloads 65
1363 Predicting Dose Level and Length of Time for Radiation Exposure Using Gene Expression

Authors: Chao Sima, Shanaz Ghandhi, Sally A. Amundson, Michael L. Bittner, David J. Brenner

Abstract:

In a large-scale radiologic emergency, potentially affected population need to be triaged efficiently using various biomarkers where personal dosimeters are not likely worn by the individuals. It has long been established that radiation injury can be estimated effectively using panels of genetic biomarkers. Furthermore, the rate of radiation, in addition to dose of radiation, plays a major role in determining biological responses. Therefore, a better and more accurate triage involves estimating both the dose level of the exposure and the length of time of that exposure. To that end, a large in vivo study was carried out on mice with internal emitter caesium-137 (¹³⁷Cs). Four different injection doses of ¹³⁷Cs were used: 157.5 μCi, 191 μCi, 214.5μCi, and 259 μCi. Cohorts of 6~7 mice from the control arm and each of the dose levels were sacrificed, and blood was collected 2, 3, 5, 7 and 14 days after injection for microarray RNA gene expression analysis. Using a generalized linear model with penalized maximum likelihood, a panel of 244 genes was established and both the doses of injection and the number of days after injection were accurately predicted for all 155 subjects using this panel. This has proven that microarray gene expression can be used effectively in radiation biodosimetry in predicting both the dose levels and the length of exposure time, which provides a more holistic view on radiation exposure and helps improving radiation damage assessment and treatment.

Keywords: caesium-137, gene expression microarray, multivariate responses prediction, radiation biodosimetry

Procedia PDF Downloads 164
1362 A Prospective Study of a Clinically Significant Anatomical Change in Head and Neck Intensity-Modulated Radiation Therapy Using Transit Electronic Portal Imaging Device Images

Authors: Wilai Masanga, Chirapha Tannanonta, Sangutid Thongsawad, Sasikarn Chamchod, Todsaporn Fuangrod

Abstract:

The major factors of radiotherapy for head and neck (HN) cancers include patient’s anatomical changes and tumour shrinkage. These changes can significantly affect the planned dose distribution that causes the treatment plan deterioration. A measured transit EPID images compared to a predicted EPID images using gamma analysis has been clinically implemented to verify the dose accuracy as part of adaptive radiotherapy protocol. However, a global gamma analysis dose not sensitive to some critical organ changes as the entire treatment field is compared. The objective of this feasibility study is to evaluate the dosimetric response to patient anatomical changes during the treatment course in HN IMRT (Head and Neck Intensity-Modulated Radiation Therapy) using a novel comparison method; organ-of-interest gamma analysis. This method provides more sensitive to specific organ change detection. Random replanned 5 HN IMRT patients with causes of tumour shrinkage and patient weight loss that critically affect to the parotid size changes were selected and evaluated its transit dosimetry. A comprehensive physics-based model was used to generate a series of predicted transit EPID images for each gantry angle from original computed tomography (CT) and replan CT datasets. The patient structures; including left and right parotid, spinal cord, and planning target volume (PTV56) were projected to EPID level. The agreement between the transit images generated from original CT and replanned CT was quantified using gamma analysis with 3%, 3mm criteria. Moreover, only gamma pass-rate is calculated within each projected structure. The gamma pass-rate in right parotid and PTV56 between predicted transit of original CT and replan CT were 42.8%( ± 17.2%) and 54.7%( ± 21.5%). The gamma pass-rate for other projected organs were greater than 80%. Additionally, the results of organ-of-interest gamma analysis were compared with 3-dimensional cone-beam computed tomography (3D-CBCT) and the rational of replan by radiation oncologists. It showed that using only registration of 3D-CBCT to original CT does not provide the dosimetric impact of anatomical changes. Using transit EPID images with organ-of-interest gamma analysis can provide additional information for treatment plan suitability assessment.

Keywords: re-plan, anatomical change, transit electronic portal imaging device, EPID, head, and neck

Procedia PDF Downloads 184
1361 Radon Concentration in the Water Samples of Hassan District, Karnataka, India

Authors: T. S. Shashikumar

Abstract:

Radon is a radioactive gas emitted from radium, a daughter product of uranium that occurs naturally in rocks and soil. Radon, together with its decay products, emits alpha particles that can damage lung tissue. The activity concentration of 222Ra has been analyzed in water samples collected from borewells and rivers in and around Hassan city, Karnataka State, India. The measurements were performed by Emanometry technique. The concentration of 222Rn in borewell waters varies from 18.49±1.89 to 397.26±12.3 Bql-1 with geometric mean 120.48±12.87 Bql-1 and in river waters it varies from 92.63±9.31 to 93.98±9.51 Bql-1 with geometric mean of 93.16±9.33 Bql-1. In the present study, the radon concentrations are higher in Adarshanagar and Viveka Nagar which are found to be 397.26±12.3 Bql-1 and 325.78±32.56 Bql-1. Most of the analysed samples show a 222Rn concentration more than 100 Bql-1 and this can be attributed to the geology of the area where the ground waters are located, which is predominantly of granitic characteristic. The average inhalation dose and ingestion dose in the borewell water are found to be 0.405 and 0.033 µSvy-1; and in river water it is found to be 0.234 and 0.019 µSvy-1, respectively. The average total effective dose rate in borewell waters and river waters are found to be 0.433 and 0.253 µSvy-1, which does not cause any health risk to the population of Hassan region.

Keywords: borewell, effective dose, emanometry, 222Rn

Procedia PDF Downloads 395
1360 Project Paulina: A Human-Machine Interface for Individuals with Limited Mobility and Conclusions from Research and Development

Authors: Radoslaw Nagay

Abstract:

The Paulina Project aims to address the challenges faced by immobilized individuals, such as those with multiple sclerosis, muscle dystrophy, or spinal cord injuries, by developing a flexible hardware and software solution. This paper presents the research and development efforts of our team, which commenced in 2019 and is now in its final stage. Recognizing the diverse needs and limitations of individuals with limited mobility, we conducted in-depth testing with a group of 30 participants. The insights gained from these tests led to the complete redesign of the system. Our presentation covers the initial project ideas, observations from in-situ tests, and the newly developed system that is currently under construction. Moreover, in response to the financial constraints faced by many disabled individuals, we propose an affordable business model for the future commercialization of our invention. Through the Paulina Project, we strive to empower immobilized individuals, providing them with greater independence and improved quality of life.

Keywords: UI, human-machine interface, social inclusion, multiple sclerosis, muscular dystrophy, spinal cord injury, quadriplegic

Procedia PDF Downloads 32
1359 Comparison of Radiation Dosage and Image Quality: Digital Breast Tomosynthesis vs. Full-Field Digital Mammography

Authors: Okhee Woo

Abstract:

Purpose: With increasing concern of individual radiation exposure doses, studies analyzing radiation dosage in breast imaging modalities are required. Aim of this study is to compare radiation dosage and image quality between digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM). Methods and Materials: 303 patients (mean age 52.1 years) who studied DBT and FFDM were retrospectively reviewed. Radiation dosage data were obtained by radiation dosage scoring and monitoring program: Radimetrics (Bayer HealthCare, Whippany, NJ). Entrance dose and mean glandular doses in each breast were obtained in both imaging modalities. To compare the image quality of DBT with two-dimensional synthesized mammogram (2DSM) and FFDM, 5-point scoring of lesion clarity was assessed and the better modality between the two was selected. Interobserver performance was compared with kappa values and diagnostic accuracy was compared using McNemar test. The parameters of radiation dosages (entrance dose, mean glandular dose) and image quality were compared between two modalities by using paired t-test and Wilcoxon rank sum test. Results: For entrance dose and mean glandular doses for each breasts, DBT had lower values compared with FFDM (p-value < 0.0001). Diagnostic accuracy did not have statistical difference, but lesion clarity score was higher in DBT with 2DSM and DBT was chosen as a better modality compared with FFDM. Conclusion: DBT showed lower radiation entrance dose and also lower mean glandular doses to both breasts compared with FFDM. Also, DBT with 2DSM had better image quality than FFDM with similar diagnostic accuracy, suggesting that DBT may have a potential to be performed as an alternative to FFDM.

Keywords: radiation dose, DBT, digital mammography, image quality

Procedia PDF Downloads 310
1358 Comparative Evaluation of Pharmacologically Guided Approaches (PGA) to Determine Maximum Recommended Starting Dose (MRSD) of Monoclonal Antibodies for First Clinical Trial

Authors: Ibraheem Husain, Abul Kalam Najmi, Karishma Chester

Abstract:

First-in-human (FIH) studies are a critical step in clinical development of any molecule that has shown therapeutic promise in preclinical evaluations, since preclinical research and safety studies into clinical development is a crucial step for successful development of monoclonal antibodies for guidance in pharmaceutical industry for the treatment of human diseases. Therefore, comparison between USFDA and nine pharmacologically guided approaches (PGA) (simple allometry, maximum life span potential, brain weight, rule of exponent (ROE), two species methods and one species methods) were made to determine maximum recommended starting dose (MRSD) for first in human clinical trials using four drugs namely Denosumab, Bevacizumab, Anakinra and Omalizumab. In our study, the predicted pharmacokinetic (pk) parameters and the estimated first-in-human dose of antibodies were compared with the observed human values. The study indicated that the clearance and volume of distribution of antibodies can be predicted with reasonable accuracy in human and a good estimate of first human dose can be obtained from the predicted human clearance and volume of distribution. A pictorial method evaluation chart was also developed based on fold errors for simultaneous evaluation of various methods.

Keywords: clinical pharmacology (CPH), clinical research (CRE), clinical trials (CTR), maximum recommended starting dose (MRSD), clearance and volume of distribution

Procedia PDF Downloads 340
1357 Accuracy of Computed Tomography Dose Monitor Values: A Multicentric Study in India

Authors: Adhimoolam Saravana Kumar, K. N. Govindarajan, B. Devanand, R. Rajakumar

Abstract:

The quality of Computed Tomography (CT) procedures has improved in recent years due to technological developments and increased diagnostic ability of CT scanners. Due to the fact that CT doses are the peak among diagnostic radiology practices, it is of great significance to be aware of patient’s CT radiation dose whenever a CT examination is preferred. CT radiation dose delivered to patients in the form of volume CT dose index (CTDIvol) values, is displayed on scanner monitors at the end of each examination and it is an important fact to assure that this information is accurate. The objective of this study was to estimate the CTDIvol values for great number of patients during the most frequent CT examinations, to study the comparison between CT dose monitor values and measured ones, as well as to highlight the fluctuation of CTDIvol values for the same CT examination at different centres and scanner models. The output CT dose indices measurements were carried out on single and multislice scanners for available kV, 5 mm slice thickness, 100 mA and FOV combination used. The 100 CT scanners were involved in this study. Data with regard to 15,000 examinations in patients, who underwent routine head, chest and abdomen CT were collected using a questionnaire sent to a large number of hospitals. Out of the 15,000 examinations, 5000 were head CT examinations, 5000 were chest CT examinations and 5000 were abdominal CT examinations. Comprehensive quality assurance (QA) was performed for all the machines involved in this work. Followed by QA, CT phantom dose measurements were carried out in South India using actual scanning parameters used clinically by the hospitals. From this study, we have measured the mean divergence between the measured and displayed CTDIvol values were 5.2, 8.4, and -5.7 for selected head, chest and abdomen procedures for protocols as mentioned above, respectively. Thus, this investigation revealed an observable change in CT practices, with a much wider range of studies being performed currently in South India. This reflects the improved capacity of CT scanners to scan longer scan lengths and at finer resolutions as permitted by helical and multislice technology. Also, some of the CT scanners have used smaller slice thickness for routine CT procedures to achieve better resolution and image quality. It leads to an increase in the patient radiation dose as well as the measured CTDIv, so it is suggested that such CT scanners should select appropriate slice thickness and scanning parameters in order to reduce the patient dose. If these routine scan parameters for head, chest and abdomen procedures are optimized than the dose indices would be optimal and lead to the lowering of the CT doses. In South Indian region all the CT machines were routinely tested for QA once in a year as per AERB requirements.

Keywords: CT dose index, weighted CTDI, volumetric CTDI, radiation dose

Procedia PDF Downloads 215
1356 Impact of a Biopesticide Formulated an Entomopathogenic Fungus Metarhizium Anisopliae et Abstracts of Two Different Plants Sage (Salvia officinalis) and American Paper (Schinus molle) on Aphis Fabae (Homoptera - Aphididae)

Authors: Hicham Abidallah

Abstract:

In this work we realized a formulation of an entomopathogenic fungus Metarhizium anisopliae with a dose of 1,7 x 105 spores/ml, and aqueous abstracts of two different plants sage (Salvia officinalis) and American paper (Schinus molle) with they’re full dose and half dose, on a black bean aphid populations (Aphis fabae) on a bean crop planted in pots at semi-controlled conditions. Five formulations were achieved (Met, Fd, F1/2d, Sd et S1/2d) and tested on six blocks each one contained six pots. This study revealed that four (04) formulations exercised an influence over black bean aphid (Met, Fd, F1/2d, Sd), of which Metarhizium marked the most elevated and aggressive toxicity with an efficiency of 99,24%, however, sage formulation with the half dose (S1/2d ) marked a weak toxicity with an efficiency of 18%. Test of Metarhizium anisopliae on bees didn’t show toxicity, and no mortality has been marked, and no trace of green Muscardine observed.

Keywords: Metarhizium anisopliae, salvia officinalis, Schinus molle, Aphis fabae, efficiency degree

Procedia PDF Downloads 324
1355 Structural and Morphological Characterization of Inorganic Deposits in Spinal Ligaments

Authors: Sylwia Orzechowska, Andrzej Wróbel, Eugeniusz Rokita

Abstract:

The mineralization is a curious problem of connective tissues. Factors which may play a decisive role in the regulation of the yellow ligaments (YL) mineralization are still open questions. The aim of the studies was a detailed description of the chemical composition and morphology of mineral deposits in the human yellow ligaments. Investigations of the structural features of deposits were used to explain the impact of various factors on mineralization process. The studies were carried out on 24 YL samples, surgically removed from patients suffer from spinal canal stenosis and the patients who sustained a trauma. The micro-computed tomography was used to describe the morphology of mineral deposits. The X-ray fluorescence method and Fourier transform infrared spectroscopy were applied to determine the chemical composition of the samples. In order to eliminate the effect of blur in microtomographic images, the correction method of partial volume effect was used. The mineral deposits appear in 60% of YL samples, both in patients with a stenosis and following injury. The mineral deposits have a heterogeneous structure and they are a mixture of the tissue and mineral grains. The volume of mineral grains amounts to (1.9 ± 3.4)*10-3 mm3 while the density distribution of grains occurs in two distinct ranges (1.75 - 2.15 and 2.15-2.5) g/cm3. Application of the partial volume effect correction allows accurate calculations by eliminating the averaging effect of gray levels in tomographic images. The B-type carbonate-containing hydroxyapatite constitutes the mineral phase of majority YLs. The main phase of two samples was calcium pyrophosphate dihydrate (CPPD). The elemental composition of minerals in all samples is almost identical. This pathology may be independent on the spine diseases and it does not evoke canal stenosis. The two ranges of grains density indicate two stages of grains growth and the degree of maturity. The presence of CPPD crystals may coexist with other pathologies.

Keywords: FTIR, micro-tomography, mineralization, spinal ligaments

Procedia PDF Downloads 346
1354 Study of Effects of Hydro-Alcoholic Extract of Asparagus Root (Asparagus officinalis) Ontestes Spermyogenesis Index of Laboratory Mouse

Authors: Hamid Karimi, Naegar Mahdavi, Hossein Tayefi Nasrabadi

Abstract:

Spermatozoids production rate and its quality are more important factors in the diagnosis of infertility. Also, spematozids activity have a more important role in fertilization. Some medicinal plants as Asparagus(Asparagus officinalis) has many antioxidant component. Therefore, They can affect testes tissue to production more and high-quality spermatozoids. In this survey, Asparagus root extract is studied on spermatogenesis index in the laboratory mouse testes. Hydro-alcoholic extract of asparagus root is prepared and examined on four group of the mature male mouse. Blank group without extract, group 1,100ml/kg dose, group 2, 200 ml/kg dose and group 3, 300ml/kg dose. Then, mice are euthanized, and testes are removed. Testes are weighted, and paraffinized blocks are prepared. TDI(Tubular Differentiation Index) and SPI(Spermiation Index) are studied on histological sections by light microscope. This study results were showed that TDI and SPI in treatments groups with 200 and 300 ml/kg dose had significant enhancement (P<0.05). Consequently, Extract of Asparagus root can enhance spermatozoid production and, therefore, cause improve fertility in male laboratory mice.

Keywords: histology, spermatozoid, ASP [aragus, testes

Procedia PDF Downloads 125
1353 Status of Radiation Protection at Radiation Oncology, BPKM Cancer Hospital, Nepal

Authors: Surendra B. Chand, P. P. Chaurasia, M. P. Adhikari, R. N. Yadav

Abstract:

Objective: The objective of this work was to evaluate all the safety procedures toward the radiation protection for workers in the radiation oncology department. Materials and Methods: The annual thermoluminescent dosimeters (TLDs) reports for five years of the staffs were evaluated, radiation surveys were done in the control consoles, radiotherapy machines room and waiting areas of all machines using Aloka survey meter. Results: The five years TLD reports shows that the whole body dose of the individual staffs is found within the annual dose limit except the accidental exposures. Radiation exposures in the working areas are also safe limits. Conclusion: The radiation safety practices for radiation protection are satisfactory and the radiation workers of the departments are found working within the safe limit.

Keywords: radiation protection, safety, ICRP, dose limits, TLD, radiation devices

Procedia PDF Downloads 533
1352 Comparison of Titanium and Aluminum Functions as Spoilers for Dose Uniformity Achievement in Abutting Oblique Electron Fields: A Monte Carlo Simulation Study

Authors: Faranak Felfeliyan, Parvaneh Shokrani, Maryam Atarod

Abstract:

Introduction Using electron beam is widespread in radiotherapy. The main criteria in radiation therapy is to irradiate the tumor volume with maximum prescribed dose and minimum dose to vital organs around it. Using abutting fields is common in radiotherapy. The main problem in using abutting fields is dose inhomogeneity in the junction region. Electron beam divergence and lateral scattering may lead to hot and cold spots in the junction region. One solution for this problem is using of a spoiler to broaden the penumbra and uniform dose in the junction region. The goal of this research was to compare titanium and aluminum effects as a spoiler for dose uniformity achievement in the junction region of oblique electron fields with Monte Carlo simulation. Dose uniformity in the junction region depends on density, scattering power, thickness of the spoiler and the angle between two fields. Materials and Methods In this study, Monte Carlo model of Siemens Primus linear accelerator was simulated for a 5 MeV nominal energy electron beam using manufacture provided specifications. BEAMnrc and EGSnrc user code were used to simulate the treatment head in electron mode (simulation of beam model). The resulting phase space file was used as a source for dose calculations for 10×10 cm2 field size at SSD=100 cm in a 30×30×45 cm3 water phantom using DOSXYZnrc user code (dose calculations). An automatic MP3-M water phantom tank, MEPHYSTO mc2 software platform and a Semi-Flex Chamber-31010 with sensitive vol­ume of 0.125 cm3 (PTW, Freiburg, Germany) were used for dose distribution measurements. Moreover, the electron field size was 10×10 cm2 and SSD=100 cm. Validation of devel­oped beam model was done by comparing the measured and calculated depth and lateral dose distributions (verification of electron beam model). Simulation of spoilers (using SLAB compo­nent module) placed at the end of the electron applicator, was done using previously vali­dated phase space file for a 5 MeV nominal energy and 10×10 cm2 field size (simulation of spoiler). An in-house routine was developed in order to calculate the combined isodose curves re­sulting from the two simulated abutting fields (calculation of dose distribution in abutting electron fields). Results Verification of the developed 5.9 MeV elec­tron beam model was done by comparing the calculated and measured dose distributions. The maximum percentage difference between calculated and measured PDD was 1%, except for the build-up region in which the difference was 2%. The difference between calculated and measured profile was 2% at the edges of the field and less than 1% in other regions. The effect of PMMA, aluminum, titanium and chromium in dose uniformity achievement in abutting normal electron fields with equivalent thicknesses to 5mm PMMA was evaluated. Comparing R90 and uniformity index of different materials, aluminum was chosen as the optimum spoiler. Titanium has the maximum surface dose. Thus, aluminum and titanium had been chosen to use for dose uniformity achievement in oblique electron fields. Using the optimum beam spoiler, junction dose decreased from 160% to 110% for 15 degrees, from 180% to 120% for 30 degrees, from 160% to 120% for 45 degrees and from 180% to 100% for 60 degrees oblique abutting fields. Using Titanium spoiler, junction dose decreased from 160% to 120% for 15 degrees, 180% to 120% for 30 degrees, 160% to 120% for 45 degrees and 180% to 110% for 60 degrees. In addition, penumbra width for 15 degrees, without spoiler in the surface was 10 mm and was increased to 15.5 mm with titanium spoiler. For 30 degrees, from 9 mm to 15 mm, for 45 degrees from 4 mm to 6 mm and for 60 degrees, from 5 mm to 8 mm. Conclusion Using spoilers, penumbra width at the surface increased, size and depth of hot spots was decreased and dose homogeneity improved at the junc­tion of abutting electron fields. Dose at the junction region of abutting oblique fields was improved significantly by using spoiler. Maximum dose at the junction region for 15⁰, 30⁰, 45⁰ and 60⁰ was decreased about 40%, 60%, 40% and 70% respectively for Titanium and about 50%, 60%, 40% and 80% for Aluminum. Considering significantly decrease in maximum dose using titanium spoiler, unfortunately, dose distribution in the junction region was not decreased less than 110%.

Keywords: abutting fields, electron beam, radiation therapy, spoilers

Procedia PDF Downloads 130
1351 Random Variation of Treated Volumes in Fractionated 2D Image Based HDR Brachytherapy for Cervical Cancer

Authors: R. Tudugala, B. M. A. I. Balasooriya, W. M. Ediri Arachchi, R. W. M. W. K. Rathnayake, T. D. Premaratna

Abstract:

Brachytherapy involves placing a source of radiation near the cancer site which gives promising prognosis for cervical cancer treatments. The purpose of this study was to evaluate the effect of random variation of treated volumes in between fractions in the 2D image based fractionated high dose rate brachytherapy for cervical cancer at National Cancer Institute Maharagama, Sri Lanka. Dose plans were analyzed for 150 cervical cancer patients with orthogonal radiographs (2D) based brachytherapy. ICRU treated volumes was modeled by translating the applicators with the help of “Multisource HDR plus software”. The difference of treated volumes with respect to the applicator geometry was analyzed by using SPSS 18 software; to derived patient population based estimates of delivered treated volumes relative to ideally treated volumes. Packing was evaluated according to bladder dose, rectum dose and geometry of the dose distribution by three consultant radiation oncologist. The difference of treated volumes depends on types of the applicators, which was used in fractionated brachytherapy. The means of the “Difference of Treated Volume” (DTV) for “Evenly activated tandem (ET)” length” group was ((X_1)) -0.48 cm3 and ((X_2)) 11.85 cm3 for “Unevenly activated tandem length (UET) group. The range of the DTV for ET group was 35.80 cm3 whereas UET group 104.80 cm3. One sample T test was performed to compare the DTV with “Ideal treatment volume difference (0.00cm3)”. It is evident that P value was 0.732 for ET group and for UET it was 0.00 moreover independent two sample T test was performed to compare ET and UET groups and calculated P value was 0.005. Packing was evaluated under three categories 59.38% used “Convenient Packing Technique”, 33.33% used “Fairly Packing Technique” and 7.29% used “Not Convenient Packing” in their fractionated brachytherapy treatments. Random variation of treated volume in ET group is much lower than UET group and there is a significant difference (p<0.05) in between ET and UET groups which affects the dose distribution of the treatment. Furthermore, it can be concluded nearly 92.71% patient’s packing were used acceptable packing technique at NCIM, Sri Lanka.

Keywords: brachytherapy, cervical cancer, high dose rate, tandem, treated volumes

Procedia PDF Downloads 158
1350 Annual Effective Dose Associated with Radon in Groundwater Samples from Mining Communities Within the Ife-Ilesha Schist Belt, Southwestern Nigeria.

Authors: Paulinah Oyindamola Fasanmi, Matthew Omoniyi Isinkaye

Abstract:

In this study, the activity concentration of ²²²Rn in groundwater samples collected from gold and kaolin mining communities within the Ife-Ilesha schist belt, southwestern Nigeria, with their corresponding annual effective doses have been determined using the Durridge RAD-7, radon-in-water detector. The mean concentration of ²²²Rn in all the groundwater samples was 13.83 Bql-¹. In borehole water, ²²²Rn had a mean value of 20.68 Bql-¹, while it had a mean value of 11.67 Bql-¹ in well water samples. The mean activity concentration of radon obtained from the gold mining communities ranged from 1.6 Bql-¹ from Igun town to 4.8 Bql-¹ from Ilesha town. A higher mean value of 41.8 Bql-¹ was, however, obtained from Ijero, which is the kaolin mining community. The mean annual effective dose due to ingestion and inhalation of radon from groundwater samples was obtained to be 35.35 μSvyr-¹ and 34.86 nSvyr-¹, respectively. The mean annual ingestion dose estimated for well water samples was 29.90 μSvyr-¹, while 52.85 μSvyr-¹ was obtained for borehole water samples. On the other hand, the mean annual inhalation dose for well water was 29.49 nSvyr-¹, while for borehole water, 52.13 nSvyr-¹ was obtained. The mean annual effective dose due to ingestion of radon in groundwater from the gold mining communities ranged from 4.10 μSvyr-¹ from Igun to 13.1 μSvyr-¹ from Ilesha, while a mean value of 106.7 μSvyr-¹ was obtained from Ijero kaolin mining community. For inhalation, the mean value varied from 4.0 nSvyr-¹ from Igun to 12.9 nSvyr-¹ from Ilesha, while 105.2 nSvyr-¹ was obtained from the kaolin mining community. The mean annual effective dose due to ingestion and inhalation is lower than the reference level of 100 μSvyr-¹ recommended by World Health Organization except for values obtained from Ijero kaolin mining community, which exceeded the reference levels. It has been concluded that as far as radon-related health risks are concerned, groundwater from gold mining communities is generally safe, while groundwater from kaolin mining communities needs mitigation and monitoring. It has been discovered that Kaolin mining impacts groundwater with ²²²Rn than gold mining. Also, the radon level in borehole water exceeds its level in well water.

Keywords: 222Rn, Groundwater, Radioactivity, Annual Effective Dose, Mining.

Procedia PDF Downloads 26
1349 Effect of Gamma Irradiation on Structural and Optical Properties of ZnO/Mesoporous Silica Nanocomposite

Authors: K. Sowri Babu, P. Srinath, N. Rajeswara Rao, K. Venugopal Reddy

Abstract:

The effect of gamma ray irradiation on morphology and optical properties of ZnO/Mesoporous silica (MPS) nanocomposite was studied. The ZnO/MPS nanocomposite was irradiated with gamma rays of doses 30, 60, and 90 kGy and dose-rate of irradiation was 0.15 kGy/hour. Irradiated samples are characterized with FE-SEM, FT-IR, UV-vis, and Photoluminescence (PL) spectrometers. SEM pictures showed that morphology changed from spherical to flake like morphology. UV-vis analysis showed that the band gap increased with increase of gamma ray irradiation dose. This enhancement of the band gap is assigned to the depletion of oxygen vacancies with irradiation. The intensity of PL peak decreased gradually with increase of gamma ray irradiation dose. The decrease in PL intensity is attributed to the decrease of oxygen vacancies at the interface due to poor interface and improper passivation between ZnO/MPS.

Keywords: ZnO nanoparticles, nanocomposites, mesoporous silica, photoluminescence

Procedia PDF Downloads 191