Search results for: heart failure
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3266

Search results for: heart failure

3236 Comparative Efficacy of Angiotensin Converting Enzymes Inhibitors and Angiotensin Receptor Blockers in Patients with Heart Failure in Tanzania: A Prospective Cohort Study

Authors: Mark P. Mayala, Henry Mayala, Khuzeima Khanbhai

Abstract:

Background: Heart failure has been a rising concern in Tanzania. New drugs have been introduced, including the group of drugs called Angiotensin receptor Neprilysin Inhibitor (ARNI), but due to their high cost, angiotensin-converting enzymes inhibitors (ACEIs) and Angiotensin receptor blockers (ARBs) have been mostly used in Tanzania. However, according to our knowledge, the efficacy comparison of the two groups is yet to be studied in Tanzania. The aim of this study was to compare the efficacy of ACEIs and ARBs among patients with heart failure. Methodology: This was a hospital-based prospective cohort study done at Jakaya Kikwete Cardiac Institution (JKCI), Tanzania, from June to December 2020. Consecutive enrollment was done until fulfilling the inclusion criteria. Clinical details were measured at baseline. We assessed the relationship between ARBs and ACEIs users with N-terminal pro-brain natriuretic peptide (NT pro-BNP) levels at admission and at 1-month follow-up using a chi-square test. A Kaplan-Meier curve was used to estimate the survival time of the two groups. Results: 155 HF patients were enrolled, with a mean age of 48 years, whereby 52.3% were male, and their mean left ventricular ejection fraction (LVEF) was 37.3%. 52 (33.5%) heart failure patients were on ACEIs, 57 (36.8%) on ARBs, and 46 (29.7%) were neither using ACEIs nor ARBs. At least half of the patients did not receive a guideline-directed medical therapy (GDMT), with only 82 (52.9%) receiving a GDMT. A drop in NT pro-BNP levels was observed during admission and at 1-month follow-up on both groups, from 6389.2 pg/ml to 4000.1 pg/ml for ARB users and 5877.7 pg/ml to 1328.2 pg/ml for the ACEIs users. There was no statistical difference between the two groups when estimated by the Kaplan-Meier curve, though more deaths were observed in those who were neither on ACEIs nor ARBs, with a calculated P value of 0.01. Conclusion: This study demonstrates that ACEIs have more efficacy and overall better clinical outcome than ARBs, but this should be taken under the patient-based case, considering the side effects of ACEIs and patients’ adherence.

Keywords: angiotensin converting enzymes inhibitors, angiotensin receptor blockers, guideline direct medical therapy, N-terminal pro-brain natriuretic peptide

Procedia PDF Downloads 49
3235 Causes of Death in Neuromuscular Disease Patients: 15-Year Experience in a Tertiary Care Hospital

Authors: Po-Ching Chou, Wen-Chen Liang, I. Chen Chen, Jong-Hau Hsu, Yuh-Jyh Jong

Abstract:

Background:Cardiopulmonary complications seem to cause high morbidity and mortality in patients with neuromuscular diseases (NMD) but so far there is no domestic data reported in Taiwan. We, therefore attempted to analyze the factors to cause the death in NMD patients from our cohort. Methods:From 1998 to 2013, we retrospectively collected the information of the NMD patients treated and followed up in Kaohsiung Medical University Hospital. Forty-two patients with NMD who expired during these fifteen years were enrolled. The medical records of these patients were reviewed and the causes of death and the associated affecting factors were analyzed. Results:Eighteen patients with NMD (mean age=13.3, SD=12.4) with complete medical record and detailed information were finally included in this study, including spinal muscular atrophy (SMA) (n=9, 7/9: type 1), Duchenne muscular dystrophy (n=6), congenital muscular dystrophy (n=1), carnitine acyl-carnitine translocase (CACT) deficiency (n=1) and spinal muscular atrophy with respiratory distress (SMARD)(n=1). The place of death was in ICU (n=11, 61%), emergency room (n=3, 16.6%) or home (n=4, 22.2%). For SMA type 1 patients, most of them (71.4%, 5/7) died in emergency room or home and the other two expired during an ICU admission. The causes of death included acute respiratory failure due to pneumonia (n=13, 72.2 %), ventilator failure or dislocation (n=2, 11.1%), suffocation/choking (n=2, 11.1%), and heart failure with hypertrophic cardiomyopathy (n=1, 5.55%). Among the 15 patients died of respiratory failure or choking, 73.3% of the patients (n=11) received no ventilator care at home. 80% of the patients (n=12) received no cough assist at home. The patient died of cardiomyopathy received no medications for heart failure until the last admission. Conclusion: Respiratory failure and choking are the leading causes of death in NMD patients. Appropriate respiratory support and airway clearance play the critical role to reduce the mortality.

Keywords: neuromuscular disease, cause of death, tertiary care hospital, medical sciences

Procedia PDF Downloads 498
3234 Assessment of Physical Activity Patterns in Patients with Cardiopulmonary Diseases

Authors: Ledi Neçaj

Abstract:

Objectives: The target of this paper is (1) to explain objectively physical activity model throughout three chronic cardiopulmonary conditions, and (2) to study the connection among physical activity dimensions with disease severity, self-reported physical and emotional functioning, and exercise performance. Material and Methods: This is a cross-sectional study of patients in their domestic environment. Patients with cardiopulmonary diseases were: chronic obstructive pulmonary disease (COPD), (n-63), coronary heart failure (n=60), and patients with implantable cardioverter defibrillator (n=60). Main results measures: Seven ambulatory physical activity dimensions (total steps, percentage time active, percentage time ambulating at low, medium, and hard intensity, maximum cadence for 30 non-stop minutes, and peak performance) have been measured with an accelerometer. Results: Subjects with COPD had the lowest amount of ambulatory physical activity compared with topics with coronary heart failure and cardiac dysrhythmias (all 7 interest dimensions, P<.05); total step counts have been: 5319 as opposed to 7464 as opposed to 9570, respectively. Six-minute walk distance becomes correlated (r=.44-.65, P<.01) with all physical activity dimensions inside the COPD pattern, the most powerful correlations being with total steps and peak performance. In topics with cardiac impairment, maximal oxygen intake had the most effective small to slight correlations with five of the physical activity dimensions (r=.22-.40, P<.05). In contrast, correlations among 6-minute walk test distance and physical activity have been higher (r=.48-.61, P<.01) albeit in a smaller pattern of most effective patients with coronary heart failure. For all three samples, self-reported physical and mental health functioning, age, frame mass index, airflow obstruction, and ejection fraction had both exceptionally small and no significant correlations with physical activity. Conclusions: Findings from this study present a profitable benchmark of physical activity patterns in individuals with cardiopulmonary diseases for comparison with future studies. All seven dimensions of ambulatory physical activity have disfavor between subjects with COPD, heart failure, and cardiac dysrhythmias. Depending on the research or clinical goal, the use of one dimension, such as total steps, may be sufficient. Although physical activity had high correlations with performance on a six-minute walk test relative to other variables, accelerometers-based physical activity monitoring provides unique, important information about real-world behavior in patients with cardiopulmonary not already captured with existing measures.

Keywords: ambulatory physical activity, walking, monitoring, COPD, heart failure, implantable defibrillator, exercise performance

Procedia PDF Downloads 58
3233 Study of the Design and Simulation Work for an Artificial Heart

Authors: Mohammed Eltayeb Salih Elamin

Abstract:

This study discusses the concept of the artificial heart using engineering concepts, of the fluid mechanics and the characteristics of the non-Newtonian fluid. For the purpose to serve heart patients and improve aspects of their lives and since the Statistics review according to world health organization (WHO) says that heart disease and blood vessels are the first cause of death in the world. Statistics shows that 30% of the death cases in the world by the heart disease, so simply we can consider it as the number one leading cause of death in the entire world is heart failure. And since the heart implantation become a very difficult and not always available, the idea of the artificial heart become very essential. So it’s important that we participate in the developing this idea by searching and finding the weakness point in the earlier designs and hoping for improving it for the best of humanity. In this study a pump was designed in order to pump blood to the human body and taking into account all the factors that allows it to replace the human heart, in order to work at the same characteristics and the efficiency of the human heart. The pump was designed on the idea of the diaphragm pump. Three models of blood obtained from the blood real characteristics and all of these models were simulated in order to study the effect of the pumping work on the fluid. After that, we study the properties of this pump by using Ansys15 software to simulate blood flow inside the pump and the amount of stress that it will go under. The 3D geometries modeling was done using SOLID WORKS and the geometries then imported to Ansys design modeler which is used during the pre-processing procedure. The solver used throughout the study is Ansys FLUENT. This is a tool used to analysis the fluid flow troubles and the general well-known term used for this branch of science is known as Computational Fluid Dynamics (CFD). Basically, Design Modeler used during the pre-processing procedure which is a crucial step before the start of the fluid flow problem. Some of the key operations are the geometry creations which specify the domain of the fluid flow problem. Next is mesh generation which means discretization of the domain to solve governing equations at each cell and later, specify the boundary zones to apply boundary conditions for the problem. Finally, the pre–processed work will be saved at the Ansys workbench for future work continuation.

Keywords: Artificial heart, computational fluid dynamic heart chamber, design, pump

Procedia PDF Downloads 430
3232 Statistical Analysis of Failure Cases in Aerospace

Authors: J. H. Lv, W. Z. Wang, S.W. Liu

Abstract:

The major concern in the aviation industry is the flight safety. Although great effort has been put onto the development of material and system reliability, the failure cases of fatal accidents still occur nowadays. Due to the complexity of the aviation system, and the interaction among the failure components, the failure analysis of the related equipment is a little difficult. This study focuses on surveying the failure cases in aviation, which are extracted from failure analysis journals, including Engineering Failure Analysis and Case studies in Engineering Failure Analysis, in order to obtain the failure sensitive factors or failure sensitive parts. The analytical results show that, among the failure cases, fatigue failure is the largest in number of occurrence. The most failed components are the disk, blade, landing gear, bearing, and fastener. The frequently failed materials consist of steel, aluminum alloy, superalloy, and titanium alloy. Therefore, in order to assure the safety in aviation, more attention should be paid to the fatigue failures.

Keywords: aerospace, disk, failure analysis, fatigue

Procedia PDF Downloads 293
3231 Breaking Stress Criterion that Changes Everything We Know About Materials Failure

Authors: Ali Nour El Hajj

Abstract:

Background: The perennial deficiencies of the failure models in the materials field have profoundly and significantly impacted all associated technical fields that depend on accurate failure predictions. Many preeminent and well-known scientists from an earlier era of groundbreaking discoveries attempted to solve the issue of material failure. However, a thorough understanding of material failure has been frustratingly elusive. Objective: The heart of this study is the presentation of a methodology that identifies a newly derived one-parameter criterion as the only general failure theory for noncompressible, homogeneous, and isotropic materials subjected to multiaxial states of stress and various boundary conditions, providing the solution to this longstanding problem. This theory is the counterpart and companion piece to the theory of elasticity and is in a formalism that is suitable for broad application. Methods: Utilizing advanced finite-element analysis, the maximum internal breaking stress corresponding to the maximum applied external force is identified as a unified and universal material failure criterion for determining the structural capacity of any system, regardless of its geometry or architecture. Results: A comparison between the proposed criterion and methodology against design codes reveals that current provisions may underestimate the structural capacity by 2.17 times or overestimate the capacity by 2.096 times. It also shows that existing standards may underestimate the structural capacity by 1.4 times or overestimate the capacity by 2.49 times. Conclusion: The proposed failure criterion and methodology will pave the way for a new era in designing unconventional structural systems composed of unconventional materials.

Keywords: failure criteria, strength theory, failure mechanics, materials mechanics, rock mechanics, concrete strength, finite-element analysis, mechanical engineering, aeronautical engineering, civil engineering

Procedia PDF Downloads 48
3230 Simulation of Human Heart Activation Based on Diffusion Tensor Imaging

Authors: Ihab Elaff

Abstract:

Simulating the heart’s electrical stimulation is essential in modeling and evaluating the electrophysiology behavior of the heart. For achieving that, there are two structures in concern: the ventricles’ Myocardium, and the ventricles’ Conduction Network. Ventricles’ Myocardium has been modeled as anisotropic material from Diffusion Tensor Imaging (DTI) scan, and the Conduction Network has been extracted from DTI as a case-based structure based on the biological properties of the heart tissues and the working methodology of the Magnetic Resonance Imaging (MRI) scanner. Results of the produced activation were much similar to real measurements of the reference model that was presented in the literature.

Keywords: diffusion tensor, DTI, heart, conduction network, excitation propagation

Procedia PDF Downloads 215
3229 Ibrutinib and the Potential Risk of Cardiac Failure: A Review of Pharmacovigilance Data

Authors: Abdulaziz Alakeel, Roaa Alamri, Abdulrahman Alomair, Mohammed Fouda

Abstract:

Introduction: Ibrutinib is a selective, potent, and irreversible small-molecule inhibitor of Bruton's tyrosine kinase (BTK). It forms a covalent bond with a cysteine residue (CYS-481) at the active site of Btk, leading to inhibition of Btk enzymatic activity. The drug is indicated to treat certain type of cancers such as mantle cell lymphoma (MCL), chronic lymphocytic leukaemia and Waldenström's macroglobulinaemia (WM). Cardiac failure is a condition referred to inability of heart muscle to pump adequate blood to human body organs. There are multiple types of cardiac failure including left and right-sided heart failure, systolic and diastolic heart failures. The aim of this review is to evaluate the risk of cardiac failure associated with the use of ibrutinib and to suggest regulatory recommendations if required. Methodology: Signal Detection team at the National Pharmacovigilance Center (NPC) of Saudi Food and Drug Authority (SFDA) performed a comprehensive signal review using its national database as well as the World Health Organization (WHO) database (VigiBase), to retrieve related information for assessing the causality between cardiac failure and ibrutinib. We used the WHO- Uppsala Monitoring Centre (UMC) criteria as standard for assessing the causality of the reported cases. Results: Case Review: The number of resulted cases for the combined drug/adverse drug reaction are 212 global ICSRs as of July 2020. The reviewers have selected and assessed the causality for the well-documented ICSRs with completeness scores of 0.9 and above (35 ICSRs); the value 1.0 presents the highest score for best-written ICSRs. Among the reviewed cases, more than half of them provides supportive association (four probable and 15 possible cases). Data Mining: The disproportionality of the observed and the expected reporting rate for drug/adverse drug reaction pair is estimated using information component (IC), a tool developed by WHO-UMC to measure the reporting ratio. Positive IC reflects higher statistical association while negative values indicates less statistical association, considering the null value equal to zero. The results of (IC=1.5) revealed a positive statistical association for the drug/ADR combination, which means “Ibrutinib” with “Cardiac Failure” have been observed more than expected when compared to other medications available in WHO database. Conclusion: Health regulators and health care professionals must be aware for the potential risk of cardiac failure associated with ibrutinib and the monitoring of any signs or symptoms in treated patients is essential. The weighted cumulative evidences identified from causality assessment of the reported cases and data mining are sufficient to support a causal association between ibrutinib and cardiac failure.

Keywords: cardiac failure, drug safety, ibrutinib, pharmacovigilance, signal detection

Procedia PDF Downloads 98
3228 Chest Pain as a Predictor for Heart Issues in Geriatrics

Authors: Leila Kargar, Homa Abri, Golsa Safai

Abstract:

The occurrence of chest pain among geriatrics could be considered as a predictor of heart issues. There is a need for attention to this pain among this population. This review paper has tried to collect the recent data with attention to the chest pain among geriatrics. This review paper has focused on specific keywords, including chest pain, heart issues, and geriatrics, among published papers from 2015 till 2020. To collect data for this purpose, Scopus, Web of Sciences, and PubMed were used. After inserting related papers to the Endnote, an independent researcher checked the abstract, and papers with unclear methods or non-English language were excluded. Finally, 7-papers were included in this review paper. The findings of those papers showed that chest pain could be a predictor for heart issues, and also, there is a direct relationship between chest pain and heart issues among geriatrics. So, early detection and an accurate decision could be helpful to prevent heart issues in this population.

Keywords: pain, heart issue, geriatrics, health

Procedia PDF Downloads 180
3227 Slovenia in the Heart of Europe

Authors: M. Žibert, T. Špindler, S. Uhan, A. Lisec

Abstract:

We can find Slovenia in the heart of Europe and has really good geographical location. With same slogan are promoted Switzerland, Montenegro, Greece and probably many others. However, from anatomic point of view, injustice is being made to someone because the heart is placed only in left part of chest cavity and there we can`t find place for the entire territory from Switzerland to the south of Balkan.

Keywords: Ljubljana, logistics, Slovenia, tourism

Procedia PDF Downloads 334
3226 Design of Demand Pacemaker Using an Embedded Controller

Authors: C. Bala Prashanth Reddy, B. Abhinay, C. Sreekar, D. V. Shobhana Priscilla

Abstract:

The project aims in designing an emergency pacemaker which is capable of giving shocks to a human heart which has stopped working suddenly. A pacemaker is a machine commonly used by cardiologists. This machine is used in order to shock a human’s heart back into usage. The way the heart works is that there are small cells called pacemakers sending electrical pulses to cardiac muscles that tell the heart when to pump blood. When these electrical pulses stop, the heart stops beating. When this happens, a pacemaker is used to shock the heart muscles and the pacemakers back into action. The way this is achieved is by rubbing the two panels of the pacemaker together to create an adequate electrical current, and then the heart gets back to the normal state. The project aims in designing a system which is capable of continuously displaying the heart beat and blood pressure of a person on LCD. The concerned doctor gets the heart beat and also the blood pressure details continuously through the GSM Modem in the form of SMS alerts. In case of abnormal condition, the doctor sends message format regarding the amount of electric shock needed. Automatically the microcontroller gives the input to the pacemaker which in turn gives the shock to the patient. Heart beat monitor and display system is a portable and a best replacement for the old model stethoscope which is less efficient. The heart beat rate is calculated manually using stethoscope where the probability of error is high because the heart beat rate lies in the range of 70 to 90 per minute whose occurrence is less than 1 sec, so this device can be considered as a very good alternative instead of a stethoscope.

Keywords: missing R wave, PWM, demand pacemaker, heart

Procedia PDF Downloads 437
3225 Failure Localization of Bipolar Integrated Circuits by Implementing Active Voltage Contrast

Authors: Yiqiang Ni, Xuanlong Chen, Enliang Li, Linting Zheng, Shizheng Yang

Abstract:

Bipolar ICs are playing an important role in military applications, mainly used in logic gates, such as inverter and NAND gate. The defect of metal break located on the step is one of the main failure mechanisms of bipolar ICs, resulting in open-circuit or functional failure. In this situation, general failure localization methods like optical beam-induced resistance change (OBIRCH) and photon emission microscopy (PEM) might not be fully effective. However, active voltage contrast (AVC) can be used as a voltage probe, which may pinpoint the incorrect potential and thus locate the failure position. Two case studies will be present in this paper on how to implement AVC for failure localization, and the detailed failure mechanism will be discussed.

Keywords: bipolar IC, failure localization, metal break, open failure, voltage contrast

Procedia PDF Downloads 249
3224 The Genetic Architecture Underlying Dilated Cardiomyopathy in Singaporeans

Authors: Feng Ji Mervin Goh, Edmund Chee Jian Pua, Stuart Alexander Cook

Abstract:

Dilated cardiomyopathy (DCM) is a common cause of heart failure. Genetic mutations account for 50% of DCM cases with TTN mutations being the most common, accounting for up to 25% of DCM cases. However, the genetic architecture underlying Asian DCM patients is unknown. We evaluated 68 patients (female= 17) with DCM who underwent follow-up at the National Heart Centre, Singapore from 2013 through 2014. Clinical data were obtained and analyzed retrospectively. Genomic DNA was subjected to next-generation targeted sequencing. Nextera Rapid Capture Enrichment was used to capture the exons of a panel of 169 cardiac genes. DNA libraries were sequenced as paired-end 150-bp reads on Illumina MiSeq. Raw sequence reads were processed and analysed using standard bioinformatics techniques. The average age of onset of DCM was 46.1±10.21 years old. The average left ventricular ejection fraction (LVEF), left ventricular diastolic internal diameter (LVIDd), left ventricular systolic internal diameter (LVIDs) were 26.1±11.2%, 6.20±0.83cm, and 5.23±0.92cm respectively. The frequencies of mutations in major DCM-associated genes were as follows TTN (5.88% vs published frequency of 20%), LMNA (4.41% vs 6%), MYH7 (5.88% vs 4%), MYH6 (5.88% vs 4%), and SCN5a (4.41% vs 3%). The average callability at 10 times coverage of each major gene were: TTN (99.7%), LMNA (87.1%), MYH7 (94.8%), MYH6 (95.5%), and SCN5a (94.3%). In conclusion, TTN mutations are not common in Singaporean DCM patients. The frequencies of other major DCM-associated genes are comparable to frequencies published in the current literature.

Keywords: heart failure, dilated cardiomyopathy, genetics, next-generation sequencing

Procedia PDF Downloads 216
3223 Heart Rate Variability Responses Pre-, during, and Post-Exercise among Special Olympics Athletes

Authors: Kearney Dover, Viviene Temple, Lynneth Stuart-Hill

Abstract:

Heart Rate Variability (HRV) is the beat-to-beat variation in adjacent heartbeats. HRV is a non-invasive measure of the autonomic nervous system (ANS) and provides information about the sympathetic (SNS) and parasympathetic (PNS) nervous systems. The HRV of a well-conditioned heart is generally high at rest, whereas low HRV has been associated with adverse outcomes/conditions, including congestive heart failure, diabetic neuropathy, depression, and hospital admissions. HRV has received very little research attention among individuals with intellectual disabilities in general or Special Olympic athletes. Purpose: 1) Having a longer post-exercise rest and recovery time to establish how long it takes for the athletes’ HRV components to return to pre-exercise levels, 2) To determine if greater familiarization with the testing processes influences HRV. Participants: Two separate samples of 10 adult Special Olympics athletes will be recruited for 2 separate studies. Athletes will be between 18 and 50 years of age and will be members of Special Olympics BC. Anticipated Findings: To answer why the Special Olympics athletes display poor cardiac responsiveness to changes in autonomic modulation during exercise. By testing the cortisol levels in the athletes, we can determine their stress levels which will then explain their measured HRV.

Keywords: 6MWT, autonomic modulation, cortisol levels, intellectual disability

Procedia PDF Downloads 277
3222 Poincare Plot for Heart Rate Variability

Authors: Mazhar B. Tayel, Eslam I. AlSaba

Abstract:

The heart is the most important part in any body organisms. It effects and affected by any factor in the body. Therefore, it is a good detector of any matter in the body. When the heart signal is non-stationary signal, therefore, it should be study its variability. So, the Heart Rate Variability (HRV) has attracted considerable attention in psychology, medicine and have become important dependent measure in psychophysiology and behavioral medicine. Quantification and interpretation of heart rate variability. However, remain complex issues are fraught with pitfalls. This paper presents one of the non-linear techniques to analyze HRV. It discusses 'What Poincare plot is?', 'How it is work?', 'its usage benefits especially in HRV', 'the limitation of Poincare cause of standard deviation SD1, SD2', and 'How overcome this limitation by using complex correlation measure (CCM)'. The CCM is most sensitive to changes in temporal structure of the Poincaré plot as compared to SD1 and SD2.

Keywords: heart rate variability, chaotic system, poincare, variance, standard deviation, complex correlation measure

Procedia PDF Downloads 365
3221 A Study of NT-ProBNP and ETCO2 in Patients Presenting with Acute Dyspnoea

Authors: Dipti Chand, Riya Saboo

Abstract:

OBJECTIVES: Early and correct diagnosis may present a significant clinical challenge in diagnosis of patients presenting to Emergency Department with Acute Dyspnoea. The common cause of acute dyspnoea and respiratory distress in Emergency Department are Decompensated Heart Failure (HF), Chronic Obstructive Pulmonary Disease (COPD), Asthma, Pneumonia, Acute Respiratory Distress Syndrome (ARDS), Pulmonary Embolism (PE), and other causes like anaemia. The aim of the study was to measure NT-pro Brain Natriuretic Peptide (BNP) and exhaled End-Tidal Carbon dioxide (ETCO2) in patients presenting with dyspnoea. MATERIAL AND METHODS: This prospective, cross-sectional and observational study was performed at the Government Medical College and Hospital, Nagpur, between October 2019 and October 2021 in patients admitted to the Medicine Intensive Care Unit. Three groups of patients were compared: (1) HFrelated acute dyspnoea group (n = 52), (2) pulmonary (COPD/PE)-related acute dyspnoea group (n = 31) and (3) sepsis with ARDS-related dyspnoea group (n = 13). All patients underwent initial clinical examination with a recording of initial vital parameters along with on-admission ETCO2 measurement, NT-proBNP testing, arterial blood gas analysis, lung ultrasound examination, 2D echocardiography, chest X-rays, and other relevant diagnostic laboratory testing. RESULTS: 96 patients were included in the study. Median NT-proBNP was found to be high for the Heart Failure group (11,480 pg/ml), followed by the sepsis group (780 pg/ml), and pulmonary group had an Nt ProBNP of 231 pg/ml. The mean ETCO2 value was maximum in the pulmonary group (48.610 mmHg) followed by Heart Failure (31.51 mmHg) and the sepsis group (19.46 mmHg). The results were found to be statistically significant (P < 0.05). CONCLUSION: NT-proBNP has high diagnostic accuracy in differentiating acute HF-related dyspnoea from pulmonary (COPD and ARDS)-related acute dyspnoea. The higher levels of ETCO2 help in diagnosing patients with COPD.

Keywords: NT PRO BNP, ETCO2, dyspnoea, lung USG

Procedia PDF Downloads 46
3220 Automatic Classification of Periodic Heart Sounds Using Convolutional Neural Network

Authors: Jia Xin Low, Keng Wah Choo

Abstract:

This paper presents an automatic normal and abnormal heart sound classification model developed based on deep learning algorithm. MITHSDB heart sounds datasets obtained from the 2016 PhysioNet/Computing in Cardiology Challenge database were used in this research with the assumption that the electrocardiograms (ECG) were recorded simultaneously with the heart sounds (phonocardiogram, PCG). The PCG time series are segmented per heart beat, and each sub-segment is converted to form a square intensity matrix, and classified using convolutional neural network (CNN) models. This approach removes the need to provide classification features for the supervised machine learning algorithm. Instead, the features are determined automatically through training, from the time series provided. The result proves that the prediction model is able to provide reasonable and comparable classification accuracy despite simple implementation. This approach can be used for real-time classification of heart sounds in Internet of Medical Things (IoMT), e.g. remote monitoring applications of PCG signal.

Keywords: convolutional neural network, discrete wavelet transform, deep learning, heart sound classification

Procedia PDF Downloads 312
3219 HRV Analysis Based Arrhythmic Beat Detection Using kNN Classifier

Authors: Onder Yakut, Oguzhan Timus, Emine Dogru Bolat

Abstract:

Health diseases have a vital significance affecting human being's life and life quality. Sudden death events can be prevented owing to early diagnosis and treatment methods. Electrical signals, taken from the human being's body using non-invasive methods and showing the heart activity is called Electrocardiogram (ECG). The ECG signal is used for following daily activity of the heart by clinicians. Heart Rate Variability (HRV) is a physiological parameter giving the variation between the heart beats. ECG data taken from MITBIH Arrhythmia Database is used in the model employed in this study. The detection of arrhythmic heart beats is aimed utilizing the features extracted from the HRV time domain parameters. The developed model provides a satisfactory performance with ~89% accuracy, 91.7 % sensitivity and 85% specificity rates for the detection of arrhythmic beats.

Keywords: arrhythmic beat detection, ECG, HRV, kNN classifier

Procedia PDF Downloads 309
3218 Hemocompatible Thin-Film Materials Recreating the Structure of the Cell Niches with High Potential for Endothelialization

Authors: Roman Major, Klaudia Trembecka- Wojciga, Juergen Markus Lackner, Boguslaw Major

Abstract:

The future and the development of science is therefore seen in interdisciplinary areas such as bio medical engineering. Self-assembled structures, similar to stem cell niches would inhibit fast division process and subsequently capture the stem cells from the blood flow. By means of surface topography and the stiffness as well as micro structure progenitor cells should be differentiated towards the formation of endothelial cells monolayer which effectively will inhibit activation of the coagulation cascade. The idea of the material surface development met the interest of the clinical institutions, which support the development of science in this area and are waiting for scientific solutions that could contribute to the development of heart assist systems. This would improve the efficiency of the treatment of patients with myocardial failure, supported with artificial heart assist systems. Innovative materials would enable the redesign, in the post project activity, construction of ventricular heart assist.

Keywords: bio-inspired materials, electron microscopy, haemocompatibility, niche-like structures, thin coatings

Procedia PDF Downloads 454
3217 A Universal Approach to Categorize Failures in Production

Authors: Konja Knüppel, Gerrit Meyer, Peter Nyhuis

Abstract:

The increasing interconnectedness and complexity of production processes raise the susceptibility of production systems to failure. Therefore, the ability to respond quickly to failures is increasingly becoming a competitive factor. The research project "Sustainable failure management in manufacturing SMEs" is developing a methodology to identify failures in the production and select preventive and reactive measures in order to correct failures and to establish sustainable failure management systems.

Keywords: failure categorization, failure management, logistic performance, production optimization

Procedia PDF Downloads 331
3216 Effect of Nicorandil, Bone Marrow-Derived Mesenchymal Stem Cells and Their Combination in Isoproterenol-Induced Heart Failure in Rats

Authors: Sarah Elsayed Mohammed, Lamiaa Ahmed Ahmed, Mahmoud Mohammed Khattab

Abstract:

Aim: The aim of the present study was to investigate whether combined nicorandil and bone marrow-derived mesenchymal stem cells (BMDMSC) treatment could offer an additional benefit in ameliorating isoproterenol (ISO)-induced heart failure in rats. Methods: ISO (85 and 170 mg/kg/day) was injected subcutaneously for 2 successive days, respectively. By day 3, electrocardiographic changes were recorded and serum was separated for determination of CK-MB level for confirmation of myocardial damage. Nicorandil (3 mg/kg/day) was then given orally with or without a single i.v. BMDMSC administration. Electrocardiography and echocardiography were recorded 2 weeks after beginning of treatment. Rats were then sacrificed and ventricles were isolated for estimation of vascular endothelial growth factor (VEGF), tumor necrosis factor-alpha (TNF-α) and transforming growth factor-beta (TGF-β) contents, caspase-3 activity as well as inducible nitric oxide synthase (iNOS) and connexin-43 protein expressions. Moreover, histological analysis of myocardial fibrosis was performed and cryosections were done for estimation of homing of BMDMSC. Results: ISO induced a significant increase in ventricles/body weight ratio, left ventricular end diastolic (LVEDD) and systolic dimensions (LVESD), ST segment and QRS duration. Moreover, myocardial fibrosis as well as VEGF, TNF-α and TGF-β contents were significantly increased. On the other hand, connexin-43 protein expression was significantly decreased, while caspase-3 and iNOS protein expressions were significantly increased. Combined therapy provided additional improvement compared to cell treatment alone towards reducing cardiac hypertrophy, fibrosis and inflammation. Furthermore, combined therapy induced significant increase in angiogenesis and BMDMSC homing and prevented ISO induced changes in iNOS, connexin-43 and caspase-3 protein expressions. Conclusion: Combined nicorandil/BMDMSC treatment was superior to BMDMSC alone towards preventing ISO-induced heart failure in rats.

Keywords: fibrosis, isoproterenol, mesenchymal stem cells, nicorandil

Procedia PDF Downloads 490
3215 Equation for Predicting Inferior Vena Cava Diameter as a Potential Pointer for Heart Failure Diagnosis among Adult in Azare, Bauchi State, Nigeria

Authors: M. K. Yusuf, W. O. Hamman, U. E. Umana, S. B. Oladele

Abstract:

Background: Dilatation of the inferior vena cava (IVC) is used as the ultrasonic diagnostic feature in patients suspected of congestive heart failure. The IVC diameter has been reported to vary among the various body mass indexes (BMI) and body shape indexes (ABSI). Knowledge of these variations is useful in precision diagnoses of CHF by imaging scientists. Aim: The study aimed to establish an equation for predicting the ultrasonic mean diameter of the IVC among the various BMI/ABSI of inhabitants of Azare, Bauchi State-Nigeria. Methodology: Two hundred physically healthy adult subjects of both sexes were classified into under, normal, over, and obese weights using their BMIs after selection using a structured questionnaire following their informed consent for an abdominal ultrasound scan. The probe was placed on the midline of the body, halfway between the xiphoid process and the umbilicus, with the marker on the probe directed towards the patient's head to obtain a longitudinal view of the IVC. The maximum IVC diameter was measured from the subcostal view using the electronic caliper of the scan machine. The mean value of each group was obtained, and the results were analysed. Results: A novel equation {(IVC Diameter = 1.04 +0.01(X) where X= BMI} has been generated for determining the IVC diameter among the populace. Conclusion: An equation for predicting the IVC diameter from individual BMI values in apparently healthy subjects has been established.

Keywords: equation, ultrasonic, IVC diameter, body adiposities

Procedia PDF Downloads 35
3214 The Influence of Winding Angle on Functional Failure of FRP Pipes

Authors: Roham Rafiee, Hadi Hesamsadat

Abstract:

In this study, a parametric finite element modeling is developed to analyze failure modes of FRP pipes subjected to internal pressure. First-ply failure pressure and functional failure pressure was determined by a progressive damage modeling and then it is validated using experimental observations. The influence of both winding angle and fiber volume fraction is studied on the functional failure of FRP pipes and it corresponding pressure. It is observed that despite the fact that increasing fiber volume fraction will enhance the mechanical properties, it will be resulted in lower values for functional failure pressure. This shortcoming can be compensated by modifying the winding angle in angle plies of pipe wall structure.

Keywords: composite pipe, functional failure, progressive modeling, winding angle

Procedia PDF Downloads 509
3213 Fast and Non-Invasive Patient-Specific Optimization of Left Ventricle Assist Device Implantation

Authors: Huidan Yu, Anurag Deb, Rou Chen, I-Wen Wang

Abstract:

The use of left ventricle assist devices (LVADs) in patients with heart failure has been a proven and effective therapy for patients with severe end-stage heart failure. Due to the limited availability of suitable donor hearts, LVADs will probably become the alternative solution for patient with heart failure in the near future. While the LVAD is being continuously improved toward enhanced performance, increased device durability, reduced size, a better understanding of implantation management becomes critical in order to achieve better long-term blood supplies and less post-surgical complications such as thrombi generation. Important issues related to the LVAD implantation include the location of outflow grafting (OG), the angle of the OG, the combination between LVAD and native heart pumping, uniform or pulsatile flow at OG, etc. We have hypothesized that an optimal implantation of LVAD is patient specific. To test this hypothesis, we employ a novel in-house computational modeling technique, named InVascular, to conduct a systematic evaluation of cardiac output at aortic arch together with other pertinent hemodynamic quantities for each patient under various implantation scenarios aiming to get an optimal implantation strategy. InVacular is a powerful computational modeling technique that integrates unified mesoscale modeling for both image segmentation and fluid dynamics with the cutting-edge GPU parallel computing. It first segments the aortic artery from patient’s CT image, then seamlessly feeds extracted morphology, together with the velocity wave from Echo Ultrasound image of the same patient, to the computation model to quantify 4-D (time+space) velocity and pressure fields. Using one NVIDIA Tesla K40 GPU card, InVascular completes a computation from CT image to 4-D hemodynamics within 30 minutes. Thus it has the great potential to conduct massive numerical simulation and analysis. The systematic evaluation for one patient includes three OG anastomosis (ascending aorta, descending thoracic aorta, and subclavian artery), three combinations of LVAD and native heart pumping (1:1, 1:2, and 1:3), three angles of OG anastomosis (inclined upward, perpendicular, and inclined downward), and two LVAD inflow conditions (uniform and pulsatile). The optimal LVAD implantation is suggested through a comprehensive analysis of the cardiac output and related hemodynamics from the simulations over the fifty-four scenarios. To confirm the hypothesis, 5 random patient cases will be evaluated.

Keywords: graphic processing unit (GPU) parallel computing, left ventricle assist device (LVAD), lumped-parameter model, patient-specific computational hemodynamics

Procedia PDF Downloads 105
3212 Intelligent Prediction System for Diagnosis of Heart Attack

Authors: Oluwaponmile David Alao

Abstract:

Due to an increase in the death rate as a result of heart attack. There is need to develop a system that can be useful in the diagnosis of the disease at the medical centre. This system will help in preventing misdiagnosis that may occur from the medical practitioner or the physicians. In this research work, heart disease dataset obtained from UCI repository has been used to develop an intelligent prediction diagnosis system. The system is modeled on a feedforwad neural network and trained with back propagation neural network. A recognition rate of 86% is obtained from the testing of the network.

Keywords: heart disease, artificial neural network, diagnosis, prediction system

Procedia PDF Downloads 413
3211 An Auxiliary Technique for Coronary Heart Disease Prediction by Analyzing Electrocardiogram Based on ResNet and Bi-Long Short-Term Memory

Authors: Yang Zhang, Jian He

Abstract:

Heart disease is one of the leading causes of death in the world, and coronary heart disease (CHD) is one of the major heart diseases. Electrocardiogram (ECG) is widely used in the detection of heart diseases, but the traditional manual method for CHD prediction by analyzing ECG requires lots of professional knowledge for doctors. This paper introduces sliding window and continuous wavelet transform (CWT) to transform ECG signals into images, and then ResNet and Bi-LSTM are introduced to build the ECG feature extraction network (namely ECGNet). At last, an auxiliary system for coronary heart disease prediction was developed based on modified ResNet18 and Bi-LSTM, and the public ECG dataset of CHD from MIMIC-3 was used to train and test the system. The experimental results show that the accuracy of the method is 83%, and the F1-score is 83%. Compared with the available methods for CHD prediction based on ECG, such as kNN, decision tree, VGGNet, etc., this method not only improves the prediction accuracy but also could avoid the degradation phenomenon of the deep learning network.

Keywords: Bi-LSTM, CHD, ECG, ResNet, sliding window

Procedia PDF Downloads 48
3210 Real-Time Nonintrusive Heart Rate Measurement: Comparative Case Study of LED Sensorics' Accuracy and Benefits in Heart Monitoring

Authors: Goran Begović

Abstract:

In recent years, many researchers are focusing on non-intrusive measuring methods when it comes to human biosignals. These methods provide solutions for everyday use, whether it’s health monitoring or finessing the workout routine. One of the biggest issues with these solutions is that the sensors’ accuracy is highly variable due to many factors, such as ambiental light, skin color diversity, etc. That is why we wanted to explore different outcomes under those kinds of circumstances in order to find the most optimal algorithm(s) for extracting heart rate (HR) information. The optimization of such algorithms can benefit the wider, cheaper, and safer application of home health monitoring, without having to visit medical professionals as often when it comes to observing heart irregularities. In this study, we explored the accuracy of infrared (IR), red, and green LED sensorics in a controlled environment and compared the results with a medically accurate ECG monitoring device.

Keywords: data science, ECG, heart rate, holter monitor, LED sensors

Procedia PDF Downloads 87
3209 A Genetic Identification of Candida Species Causing Intravenous Catheter-Associated Candidemia in Heart Failure Patients

Authors: Seyed Reza Aghili, Tahereh Shokohi, Shirin Sadat Hashemi Fesharaki, Mohammad Ali Boroumand, Bahar Salmanian

Abstract:

Introduction: Intravenous catheter-associated fungal infection as nosocomial infection continue to be a deep problem among hospitalized patients, decreasing quality of life and adding healthcare costs. The capacity of catheters in the spread of candidemia in heart failure patients is obvious. The aim of this study was to evaluate the prevalence and genetic identification of Candida species in heart disorder patients. Material and Methods: This study was conducted in Tehran Hospital of Cardiology Center (Tehran, Iran, 2014) during 1.5 years on the patients hospitalized for at least 7 days and who had central or peripheral vein catheter. Culture of catheters, blood and skin of the location of catheter insertion were applied for detecting Candida colonies in 223 patients. Identification of Candida species was made on the basis of a combination of various phenotypic methods and confirmed by sequencing the ITS1-5.8S-ITS2 region amplified from the genomic DNA using PCR and the NCBI BLAST. Results: Of the 223 patients samples tested, we identified totally 15 Candida isolates obtained from 9 (4.04%) catheter cultures, 3 (1.35%) blood cultures and 2 (0.90%) skin cultures of the catheter insertion areas. On the base of ITS region sequencing, out of nine Candida isolates from catheter, 5(55.6%) C. albicans, 2(22.2%) C. glabrata, 1(11.1%) C. membranifiaciens and 1 (11.1%) C. tropicalis were identified. Among three Candida isolates from blood culture, C. tropicalis, C. carpophila and C. membranifiaciens were identified. Non-candida yeast isolated from one blood culture was Cryptococcus albidus. One case of C. glabrata and one case of Candida albicans were isolated from skin culture of the catheter insertion areas in patients with positive catheter culture. In these patients, ITS region of rDNA sequence showed a similarity between Candida isolated from the skin and catheter. However, the blood samples of these patients were negative for fungal growth. We report two cases of catheter-related candidemia caused by C. membranifiaciens and C. tropicalis on the base of genetic similarity of species isolated from blood and catheter which were treated successfully with intravenous fluconazole and catheter removal. In phenotypic identification methods, we could only identify C. albicans and C. tropicalis and other yeast isolates were diagnosed as Candida sp. Discussion: Although more than 200 species of Candida have been identified, only a few cause diseases in humans. There is some evidence that non-albicans infections are increasing. Many risk factors, including prior antibiotic therapy, use of a central venous catheter, surgery, and parenteral nutrition are considered to be associated with candidemia in hospitalized heart failure patients. Identifying the route of infection in candidemia is difficult. Non-albicans candida as the cause of candidemia is increasing dramatically. By using conventional method, many non-albicans isolates remain unidentified. So, using more sensitive and specific molecular genetic sequencing to clarify the aspects of epidemiology of the unknown candida species infections is essential. The positive blood and catheter cultures for candida isolates and high percentage of similarity of their ITS region of rDNA sequence in these two patients confirmed the diagnosis of intravenous catheter-associated candidemia.

Keywords: catheter-associated infections, heart failure patient, molecular genetic sequencing, ITS region of rDNA, Candidemia

Procedia PDF Downloads 297
3208 Computational Fluid Dynamics Simulation and Comparison of Flow through Mechanical Heart Valve Using Newtonian and Non-Newtonian Fluid

Authors: D. Šedivý, S. Fialová

Abstract:

The main purpose of this study is to show differences between the numerical solution of the flow through the artificial heart valve using Newtonian or non-Newtonian fluid. The simulation was carried out by a commercial computational fluid dynamics (CFD) package based on finite-volume method. An aortic bileaflet heart valve (Sorin Bicarbon) was used as a pattern for model of real heart valve replacement. Computed tomography (CT) was used to gain the accurate parameters of the valve. Data from CT were transferred in the commercial 3D designer, where the model for CFD was made. Carreau rheology model was applied as non-Newtonian fluid. Physiological data of cardiac cycle were used as boundary conditions. Outputs were taken the leaflets excursion from opening to closure and the fluid dynamics through the valve. This study also includes experimental measurement of pressure fields in ambience of valve for verification numerical outputs. Results put in evidence a favorable comparison between the computational solutions of flow through the mechanical heart valve using Newtonian and non-Newtonian fluid.

Keywords: computational modeling, dynamic mesh, mechanical heart valve, non-Newtonian fluid

Procedia PDF Downloads 351
3207 The Effect of Heart Rate and Valence of Emotions on Perceived Intensity of Emotion

Authors: Madeleine Nicole G. Bernardo, Katrina T. Feliciano, Marcelo Nonato A. Nacionales III, Diane Frances M. Peralta, Denise Nicole V. Profeta

Abstract:

This study aims to find out if heart rate variability and valence of emotion have an effect on perceived intensity of emotion. Psychology undergraduates (N = 60) from the University of the Philippines Diliman were shown 10 photographs from the Japanese Female Facial Expression (JAFFE) Database, along with a corresponding questionnaire with a Likert scale on perceived intensity of emotion. In this 3 x 2 mixed subjects factorial design, each group was either made to do a simple exercise prior to answering the questionnaire in order to increase the heart rate, listen to a heart rate of 120 bpm, or colour a drawing to keep the heart rate stable. After doing the activity, the participants then answered the questionnaire, providing a rating of the faces according to the participants’ perceived emotional intensity on the photographs. The photographs presented were either of positive or negative emotional valence. The results of the experiment showed that neither an induced fast heart rate or perceived fast heart rate had any significant effect on the participants’ perceived intensity of emotion. There was also no interaction effect of heart rate variability and valence of emotion. The insignificance of results was explained by the Philippines’ high context culture, accompanied by the prevalence of both intensely valenced positive and negative emotions in Philippine society. Insignificance in the effects were also attributed to the Cannon-Bard theory, Schachter-Singer theory and various methodological limitations.

Keywords: heart rate variability, perceived intensity of emotion, Philippines , valence of emotion

Procedia PDF Downloads 211