62 Experimental Investigation on the Effect of Adding CuO Nanoparticles to R-600a Refrigerant on Heat Transfer Enhancement of a Horizontal Flattened Tube

Authors: M. A. Akhavan-Behabadi, M. Najafi, A. Abbasi

Abstract:

An empirical investigation was performed in order to study the heat transfer characteristics of R600a flow boiling inside horizontal flattened tubes and the simultaneous effect of nanoparticles on boiling heat transfer in flattened channel. Round copper tubes of 8.7 mm I.D. were deformed into flattened shapes with different inside heights of 6.9, 5.5, and 3.4 mm as test areas. The effect of different parameters such as mass flux, vapor quality and inside height on heat transfer coefficient was studied. Flattening the tube caused significant enhancement in heat transfer performance so that the maximum augmentation ratio of 163% was obtained in flattened channel with lowest internal height. A new correlation was developed based on the present experimental data to predict the heat transfer coefficient in flattened tubes. This correlation estimated 90% of the entire database within ±20%.

Keywords: nano particles, flattend tube, R600a, CuO

Procedia PDF Downloads 288
61 The Effect of Adding CuO Nanoparticles on Boiling Heat Transfer Enhancement in Horizontal Flattened Tubes

Authors: M. A. Akhavan-Behabadi, M. Najafi, A. Abbasi

Abstract:

An empirical investigation was performed in order to study the heat transfer characteristics of R600a flow boiling inside horizontal flattened tubes and the simultaneous effect of nanoparticles on boiling heat transfer in flattened channel. Round copper tubes of 8.7 mm I.D. were deformed into flattened shapes with different inside heights of 6.9, 5.5, and 3.4 mm as test areas. The effect of different parameters such as mass flux, vapor quality and inside height on heat transfer coefficient was studied. Flattening the tube caused a significant enhancement in heat transfer performance, so that the maximum augmentation ratio of 163% was obtained in flattened channel with lowest internal height. A new correlation was developed based on the present experimental data to predict the heat transfer coefficient in flattened tubes. This correlation estimated 90% of the entire database within ±20%. The best flat channel with the point of view of heat transfer performance was selected to study the effect of nanoparticle on heat transfer enhancement. Four homogenized mixtures containing 1% weight fraction of R600a/oil with different CuO nanoparticles concentration including 0.5%, 1% and 1.5% mass fraction of R600a/oil/CuO were studied. Observations show that heat transfer was improved by adding nanoparticles, which lead to maximum enhancement of 79% compare to the pure refrigerant at the same test condition.

Keywords: nano fluids, heat transfer, flattend tube, transport phenomena

Procedia PDF Downloads 394
60 Commissioning of a Flattening Filter Free (FFF) using an Anisotropic Analytical Algorithm (AAA)

Authors: Safiqul Islam, Anamul Haque, Mohammad Amran Hossain

Abstract:

Aim: To compare the dosimetric parameters of the flattened and flattening filter free (FFF) beam and to validate the beam data using anisotropic analytical algorithm (AAA). Materials and Methods: All the dosimetric data’s (i.e. depth dose profiles, profile curves, output factors, penumbra etc.) required for the beam modeling of AAA were acquired using the Blue Phantom RFA for 6 MV, 6 FFF, 10MV & 10FFF. Progressive resolution Optimizer and Dose Volume Optimizer algorithm for VMAT and IMRT were are also configured in the beam model. Beam modeling of the AAA were compared with the measured data sets. Results: Due to the higher and lover energy component in 6FFF and 10 FFF the surface doses are 10 to 15% higher compared to flattened 6 MV and 10 MV beams. FFF beam has a lower mean energy compared to the flattened beam and the beam quality index were 6 MV 0.667, 6FFF 0.629, 10 MV 0.74 and 10 FFF 0.695 respectively. Gamma evaluation with 2% dose and 2 mm distance criteria for the Open Beam, IMRT and VMAT plans were also performed and found a good agreement between the modeled and measured data. Conclusion: We have successfully modeled the AAA algorithm for the flattened and FFF beams and achieved a good agreement with the calculated and measured value.

Keywords: commissioning of a Flattening Filter Free (FFF) , using an Anisotropic Analytical Algorithm (AAA), flattened beam, parameters

Procedia PDF Downloads 270
59 Designing a Dispersion Flattened Single Mode PCF for E-Band to U-Band with Less Effective Area

Authors: Shabbir Chowdhury

Abstract:

A signal is broadened when it is gone through a channel, this phenomenon is known as dispersion. And dispersion is different for different wavelength. So bandwidth become limited. Research have tried to design an optical fiber with flattened dispersion to use more bandwidth and also for wavelength division multiplexing. In this paper, a single mode photonic crystal fiber with a flattened dispersion and less effective area has been proposed where silica is used as fiber materials. The effective dispersion varies from -1.996 to 0.1783 [ps/(nm-km)] for enter E-band to U-band. This fiber will take only 3.048 [micrometer^2] (for 1.75 micrometer wavelength). Silica is being used as the fiber material.

Keywords: photonic crystal fiber, dispersion, bandwidth, chromatic dispersion, effective dispersion, dispersion compensation, effective area, effective refractive index

Procedia PDF Downloads 374
58 The First Report of Aberrant Corneal Occlusion in Rabbit in Iran

Authors: Bahador Bardshiri, Omid Moradi, Amir Komeilian, Nima Panahifar

Abstract:

Formation of a conjunctival membrane over the corneal surface is a condition unique to rabbits that has been labeled aberrant corneal occlusion or pseudopterygium. In the summer of 2013, a five years old male Standard Chinchilla rabbit were presented to Karaj Central Veterinary hospital and the owner complained that his rabbit shows degrees of blindness and there were opacities on both eyes of the presented rabbit. Ophthalmic examination of the affected eyes revealed a conjunctival fold stretching over the cornea of both eyes. The fold originated from limbus and it was vascularized and centrally thickened. There were no attachments to the corneal epithelium and the fold could be easily lifted. Surgery was performed under general anesthesia. The conjunctival fold was incised centrifugally up to its attachment at the limbus and the lid margin using small scissors. The central rim of the segment was then replaced to its normal position in the fornix and fixed with mattress sutures (7/0) passing through outside skin. After the surgery, eye drops containing dexamethasone, gentamicin and polymixin were applied twice daily up to 3 weeks. Within the observation period (8 months) no recurrence was noted. "Pseudo" in the term pseudopterygium refers to the fact that the conjunctival membrane is not adhering to the underlying cornea, but growing over it. In rare cases, the membrane may be loosely attached to the cornea, but can be easily separated without causing damage. It can cover only a small part of the cornea with an annular peripheral opacification of the cornea, or cover it almost fully, leading to blindness. Ethiopathogenesis remains unclear and recurrence of the problem is very likely. The surgical technique that used here decreases probability of recurrence of conjunctival fold.

Keywords: rabbit, cornea, aberrant corneal occlusion, pseudopterygium

Procedia PDF Downloads 298
57 Moral Obligation as a Governor to Skeptical Theism's Relativism

Authors: Peter J. Morgan

Abstract:

In response to evidential arguments from evil, Stephen Wykstra presents CORNEA (Condition of Reasonable Epistemic Access) as a foundational principle for Skeptical Theism which urges one to think in terms of what can be expected in a given situation. The use of CORNEA results in skepticism regarding the ability of human ken to know divine levels of knowledge in instances of intense evil. However, William Rowe presents a critique of Skeptical Theism that questions its ability to argue successfully for theism. Rowe contends that siding with Skeptical Theism is akin to boarding a trolley car that does not stop. Contra Wykstra, Rowe observes that, for all that can be known, there could be greater amounts of evils than goods, and the goods that are seen may not be the best possible goods. This amounts to a mortally challenging critique of Skeptical Theism. However, there is a brake on Rowe’s Trolley. This paper makes the argument that the ubiquitous presence of Moral Obligation (MO) serves as a braking system for Rowe’s Trolley. When the rider begins to feel lost in an epistemic stalemate of good and evil it is MO that turns the tide: MO serves as evidence towards the good on a basic human level, and it is a reminder that God’s character will result in actions towards the good.

Keywords: CORNEA, moral obligation, problem of evil, skeptical theism

Procedia PDF Downloads 170
56 Light and Scanning Electron Microscopic Studies on Corneal Ontogeny in Buffalo

Authors: M. P. S. Tomar, Neelam Bansal

Abstract:

Histomorphological, histochemical and scanning electron microscopic observations were recorded in developing cornea of buffalo fetuses. The samples from fetal cornea were collected in appropriate fixative from slaughter house and Veterinary Clinics, GADVASU, Ludhiana. The microscopic slides were stained for detailed histomorphological and histochemical studies. The scanning electron microscopic studies were performed at Electron microscopy & Nanobiology Lab, PAU Ludhiana. In present study, it was observed that, in 36 days (d) fetus, the corneal epithelium was well marked single layered structure which was placed on stroma mesenchyme. Cornea appeared as the continuation of developing sclera. The thickness of cornea and its epithelium increased as well as the epithelium started becoming double layered in 47d fetus at corneo-scleral junction. The corneal thickness in this stage suddenly increased thus easily distinguished from developing sclera. The separation of corneal endothelium from stroma was evident as a single layered epithelium. The stroma possessed numerous fibroblasts in 49d stage eye. Descemet’s membrane was appeared at 52d stage. The limbus area was separated by a depression from the developing cornea in 61d stage. In 65d stage, the Bowman’s layer was more developed. Fibroblasts were arranged parallel to each other as well as parallel to the surface of developing cornea in superficial layers. These fibroblasts and fibers were arranged in wavy pattern in the center of stroma. Corneal epithelium started to be stratified as a double layered epithelium was present in this age of fetal eye. In group II (>120 Days), the corneal epithelium was stratified towards a well marked irido-corneal angle. The stromal fibroblasts followed a complete parallel arrangement in its entire thickness. In full term fetuses, a well developed cornea was observed. It was a fibrous layer which had five distinct layers. From outside to inwards were described as the outer most layer was the 7-8 layered corneal epithelial, subepithelial basement membrane (Bowman’s membrane), substantia propria or stroma, posterior limiting membrane (Descemet’s membrane) and the posterior epithelium (corneal endothelium). The corneal thickness and connective tissue elements were continued to be increased. It was 121.39 + 3.73µ at 36d stage which increased to 518.47 + 4.98 µ in group III fetuses. In fetal life, the basement membrane of corneal epithelium and endothelium depicted strong to intense periodic Acid Schiff’s (PAS) reaction. At the irido-corneal angle, the endothelium of blood vessels was also positive for PAS activity. However, cornea was found mild positive for alcian blue reaction. The developing cornea showed strong reaction for basic proteins in outer epithelium and the inner endothelium layers. Under low magnification scanning electron microscope, cornea showed two types of cells viz. light cells and dark cells. The light cells were smaller in size and had less number of microvilli in their surface than in the dark cells. Despite these surface differences between light and dark cells, the corneal surface showed the same general pattern of microvilli studding all exposed surfaces out to the cell margin. which were long (with variable height), slight tortuous slender and possessed a micro villus shaft with a very prominent knob.

Keywords: buffalo, cornea, eye, fetus, ontogeny, scanning electron microscopy

Procedia PDF Downloads 113
55 Alternate Optical Coherence Tomography Technologies in Use for Corneal Diseases Diagnosis in Dogs and Cats

Authors: U. E. Mochalova, A. V. Demeneva, Shilkin A. G., J. Yu. Artiushina

Abstract:

Objective. In medical ophthalmology OCT has been actively used in the last decade. It is a modern non-invasive method of high-precision hardware examination, which gives a detailed cross-sectional image of eye tissues structure with a high level of resolution, which provides in vivo morphological information at the microscopic level about corneal tissue, structures of the anterior segment, retina and optic nerve. The purpose of this study was to explore the possibility of using the OCT technology in complex ophthalmological examination in dogs and cats, to characterize the revealed pathological structural changes in corneal tissue in cats and dogs with some of the most common corneal diseases. Procedures. Optical coherence tomography of the cornea was performed in 112 animals: 68 dogs and 44 cats. In total, 224 eyes were examined. Pathologies of the organ of vision included: dystrophy and degeneration of the cornea, endothelial corneal dystrophy, dry eye syndrome, chronic superficial vascular keratitis, pigmented keratitis, corneal erosion, ulcerative stromal keratitis, corneal sequestration, chronic glaucoma and also postoperative period after performed keratoplasty. When performing OCT, we used certified medical devices: "Huvitz HOCT-1/1F», «Optovue iVue 80» and "SOCT Copernicus Revo (60)". Results. The results of a clinical study on the use of optical coherence tomography (OCT)of the cornea in cats and dogs, performed by the authors of the article in the complex diagnosis of keratopathies of variousorigins: endothelial corneal dystrophy, pigmented keratitis, chronic keratoconjunctivitis, chronic herpetic keratitis, ulcerative keratitis, traumatic corneal damage, sequestration of the cornea of cats, chronic keratitis, complicating the course of glaucoma. The characteristics of the OCT scans are givencorneas of cats and dogs that do not have corneal pathologies. OCT scans of various corneal pathologies in dogs and cats with a description of the revealed pathological changes are presented. Of great clinical interest are the data obtained during OCT of the cornea of animals undergoing keratoplasty operations using various forms of grafts. Conclusions. OCT makes it possible to assess the thickness and pathological structural changes of the corneal surface epithelium, corneal stroma and descemet membrane. We can measure them, determine the exact localization, and record pathological changes. Clinical observation of the dynamics of the pathological process in the cornea using OCT makes it possible to evaluate the effectiveness of drug treatment. In case of negative dynamics of corneal disease, it is necessary to determine the indications for surgical treatment (to assess the thickness of the cornea, the localization of its thinning zones, to characterize the depth and area of pathological changes). According to the OCT of the cornea, it is possible to choose the optimal surgical treatment for the patient, the technique and depth of optically constructive surgery (penetrating or anterior lamellar keratoplasty).; determine the depth and diameter of the planned microsurgical trepanation of corneal tissue, which will ensure good adaptation of the edges of the donor material.

Keywords: optical coherence tomography, corneal sequestration, optical coherence tomography of the cornea, corneal transplantation, cat, dog

Procedia PDF Downloads 26
54 Comparison of Intraocular Pressure Measurement Prior and Following Full Intracorneal Ring Implantation in Patient with Keratoconus by Three Different Instruments

Authors: Seyed Aliasghar Mosavi, Mostafa Naderi, Khosrow Jadidi, Amir Hashem Mohammadi

Abstract:

To study the measurement of intraocular pressure (IOP) before and after implantation of intrastromal corneal ring (MyoRing) in patients with keratoconus. Setting: Baqiyatallah University of Medical Sciences, Tehran, Iran. Methods: We compared the IOP of 13 eyes which underwent MyoRing implantation prior and six months post operation using Goldman applanation (as gold standard), Icare, and Corvis ST (uncorrected, corrected and corrected with cornea biomechanics). Results: The resulting intraocular pressure measurements prior to surgery, Icare, Corvis (corrected with cornea biomechanics) overestimated the IOP, however measurements by Corvis uncorrected underestimate the IOP. The resulting intraocular pressure measurements after surgery, Icare, Corvis (corrected with cornea biomechanics) overestimated the IOP but measurements by Corvis uncorrected underestimate the IOP. Conclusion: Consistent intraocular pressure measurements on eyes with Myoring in keratoconus can be obtained with the Goldman applanation tonometer as the gold standard measurement. We were not able to obtain consistent results when we measured the IOP by Icare and Corvis prior and after surgery.

Keywords: intraocular pressure, MyoRing, Keratoconus, Goldmann applanation, Icare, Corvis ST

Procedia PDF Downloads 210
53 Study into the Interactions of Primary Limbal Epithelial Stem Cells and HTCEPI Using Tissue Engineered Cornea

Authors: Masoud Sakhinia, Sajjad Ahmad

Abstract:

Introduction: Though knowledge of the compositional makeup and structure of the limbal niche has progressed exponentially during the past decade, much is yet to be understood. Identifying the precise profile and role of the stromal makeup which spans the ocular surface may inform researchers of the most optimum conditions needed to effectively expand LESCs in vitro, whilst preserving their differentiation status and phenotype. Limbal fibroblasts, as opposed to corneal fibroblasts are thought to form an important component of the microenvironment where LESCs reside. Methods: The corneal stroma was tissue engineered in vitro using both limbal and corneal fibroblasts embedded within a tissue engineered 3D collagen matrix. The effect of these two different fibroblasts on LESCs and hTCEpi corneal epithelial cell line were then subsequently determined using phase contrast microscopy, histolological analysis and PCR for specific stem cell markers. The study aimed to develop an in vitro model which could be used to determine whether limbal, as opposed to corneal fibroblasts, maintained the stem cell phenotype of LESCs and hTCEpi cell line. Results: Tissue culture analysis was inconclusive and required further quantitative analysis for remarks on cell proliferation within the varying stroma. Histological analysis of the tissue-engineered cornea showed a comparable structure to that of the human cornea, though with limited epithelial stratification. PCR results for epithelial cell markers of cells cultured on limbal fibroblasts showed reduced expression of CK3, a negative marker for LESC’s, whilst also exhibiting a relatively low expression level of P63, a marker for undifferentiated LESCs. Conclusion: We have shown the potential for the construction of a tissue engineered human cornea using a 3D collagen matrix and described some preliminary results in the analysis of the effects of varying stroma consisting of limbal and corneal fibroblasts, respectively, on the proliferation of stem cell phenotype of primary LESCs and hTCEpi corneal epithelial cells. Although no definitive marker exists to conclusively illustrate the presence of LESCs, the combination of positive and negative stem cell markers in our study were inconclusive. Though it is less traslational to the human corneal model, the use of conditioned medium from that of limbal and corneal fibroblasts may provide a more simple avenue. Moreover, combinations of extracellular matrices could be used as a surrogate in these culture models.

Keywords: cornea, Limbal Stem Cells, tissue engineering, PCR

Procedia PDF Downloads 243
52 Computational Modeling of Perpendicular to Grain Stress in a Non-Standard Glulam Beam

Authors: Wojciech Gilewski, Anna Al Sabouni-Zawadzka, Jan Pelczynski

Abstract:

This paper focuses on the analysis of tensile stresses perpendicular to the grain in simply supported beams with different geometry made of glued laminated timber. Two types of beams are considered: standard double-tapered beams described in Eurocode 5 and non-standard glulam beams with a flattened apex. The beams are analyzed using two methodology approaches: a code design verification method and a finite element method (FEM) in terms of the linear theory of elasticity with plane stress assumption. The performed analyses proved that both methodologies lead to consistent results in case of standard glulam beams and therefore, the FEM can be used in case of non-standard structures, which are not included in Eurocode 5. Moreover, the FE analysis of the glulam beam with a flattened apex showed that it can be treated as a structure with two apex zones.

Keywords: double-tapered beams, finite element analysis, glued laminated timber, perpendicular to grain stress

Procedia PDF Downloads 200
51 3D Shape Knitting: Loop Alignment on a Surface with Positive Gaussian Curvature

Authors: C. T. Cheung, R. K. P. Ng, T. Y. Lo, Zhou Jinyun

Abstract:

This paper aims at manipulating loop alignment in knitting a three-dimensional (3D) shape by its geometry. Two loop alignment methods are introduced to handle a surface with positive Gaussian curvature. As weft knitting is a two-dimensional (2D) knitting mechanism that the knitting cam carrying the feeders moves in two directions only, left and right, the knitted fabric generated grows in width and length but not in depth. Therefore, a 3D shape is required to be flattened to a 2D plane with surface area preserved for knitting. On this flattened plane, dimensional measurements are taken for loop alignment. The way these measurements being taken derived two different loop alignment methods. In this paper, only plain knitted structure was considered. Each knitted loop was taken as a basic unit for loop alignment in order to achieve the required geometric dimensions, without the inclusion of other stitches which give textural dimensions to the fabric. Two loop alignment methods were experimented and compared. Only one of these two can successfully preserve the dimensions of the shape.

Keywords: 3D knitting, 3D shape, loop alignment, positive Gaussian curvature

Procedia PDF Downloads 312
50 Kocuria Keratitis: A Rare and Diagnostically Challenging Infection of the Cornea

Authors: Sarah Jacqueline Saram, Diya Baker, Jaishree Gandhewar

Abstract:

Named after the Slovakian microbiologist, Miroslav Kocur, the Kocuria spp. are an emerging cause of significant human infections. Their predilection for immunocompromised states, such as malignancy and metabolic disorders, is highlighted in the literature. The coagulase-negative, gram-positive cocci are commensals found in the skin and oropharynx of humans, and their growing presence as responsible organisms in ocular infections cannot be ignored. The severe, rapid, and unrelenting disease course associated with Kocuria keratitis is underlined in the literature. However, the clinical features are variable, which may impede making a diagnosis. Here, we describe a first account of an initial misdiagnosis due to reliance on subjective analysis features on a confocal microscope, which ultimately led to a delay in commencing the correct treatment. In documenting this, we hope to underline to clinicians the difficulties in recognising a Kocuria Rhizophilia keratitis due to its similar clinical presentation to an Acanthamoeba Keratitis, thus emphasizing the need for early investigations such as corneal scrapes to secure the correct diagnosis and prevent further harm and vision loss for the patient.

Keywords: keratitis, cornea, infection, rare, Kocuria

Procedia PDF Downloads 13
49 A Case Report on Neonatal Conjunctivitis in Pugs

Authors: Maria L. G. Lourenco, Viviane Y. Hibaru, Keylla H. N. P. Pereira, Fabiana F. Souza, Joao C. P. Ferreira, Simone B. Chiacchio, Luiz H. A. Machado

Abstract:

Neonatal conjunctivitis, or ophthalmia, is an infection of the conjunctiva or cornea before opening the eyelids. It is believed that immunodeficiency contributes to the development of the condition. This study aims at reporting a case of ophthalmia neonatorum in a dog, in addition to its diagnosis and treatment. A litter of five pug neonates was admitted to the Sao Paulo State University (UNESP) Veterinary Hospital, Botucatu, Sao Paulo, Brazil, with complaints of ocular secretion. The neonates were five days old. The clinical examination revealed that three newborns presented swelling in the ocular region and a purulent secretion in the medial corner of the eye that was exerting pressure on the ocular globes, which are compatible with the description of this disease. The diagnosis was made based on the clinical signs and bacterial culture of the secretion, which revealed the presence of bacteria belonging to the genus Staphylococcus sp. The laboratory assays did not reveal any alterations. The treatment was instituted gently, opening the eyelids early and cleaning the purulent ocular secretion with saline solution. An ophthalmic ointment with retinol, amino acids, methionine, and chloramphenicol (Epitezan®) was prescribed four times a day for seven days. Blood plasma (2 mL/100 g) was administered subcutaneously because bacterial infections in neonates may represent a failure in the transference of passive immunity. A more thorough cleaning of the environment was also recommended. Neonatal conjunctivitis has a simple diagnosis and treatment. If not treated early, it can evolve to adherence of the eyelids to the cornea, ulceration, and perforation of the cornea. Therefore, the prognosis is favorable as long as the condition is diagnosed early, and the treatment is instituted quickly.

Keywords: ophthalmia neonatorum, neonatal infection, puppy, newborn

Procedia PDF Downloads 100
48 Umbilical Cord-Derived Cells in Corneal Epithelial Regeneration

Authors: Hasan Mahmud Reza

Abstract:

Extensive studies of the human umbilical cord, both basic and translational, over the last three decades have unveiled a plethora of information. The cord lining harbors at least two phenotypically different multipotent stem cells: mesenchymal stem cells (MSCs) and cord lining epithelial stem cells (CLECs). These cells exhibit a mixed genetic profiling of both embryonic and adult stem cells, hence display a broader stem features than cells from other sources. We have observed that umbilical cord-derived cells are immunologically privileged and non-tumorigenic by animal study. These cells are ethically acceptable, thus provides a significant advantage over other stem cells. The high proliferative capacity, viability, differentiation potential, and superior harvest of these cells have made them better candidates in comparison to contemporary adult stem cells. Following 30 replication cycles, these cells have been observed to retain their stemness, with their phenotype and karyotype intact. Transplantation of bioengineered CLEC sheets in limbal stem cell-deficient rabbit eyes resulted in regeneration of clear cornea with phenotypic expression of the normal cornea-specific epithelial cytokeratin markers. The striking features of low immunogenicity protecting self along with co-transplanted allografts from rejection largely define the transplantation potential of umbilical cord-derived stem cells.

Keywords: cord lining epithelial stem cells, mesenchymal stem cell, regenerative medicine, umbilical cord

Procedia PDF Downloads 114
47 The Possible Role of the Endoneurial Fibroblast-like Cells in Resolution of the Endoneurial Edema Following Nerve Crush Injury

Authors: Faris M. Altaf, Abdullah M Elkeshy

Abstract:

Forty-two albino male rats aged between 30 and 40 days (weighted 200 g to 250 g) were used in the present study. The left sural nerves of 36 rats were subjected to crush injury at 1 to 6 weeks intervals using 6 animals at each interval. The right and left sural nerves of the rest 6 rats were used as a control. After 2 weeks of the crush injury, the endoneurium showed channel-like spaces that were lined by the fibroblast-like cells and collagen bundles. These channels contained degenerated myelin and were connected with the perivascular and subperineurial spaces. Some of the flattened fibroblast-like cells were arranged in several layers in the subperineurial and perivascular spaces, forming barrier-like cellular sheets localizing the endoneurial edema in these spaces. Fibroblast-like cells also wrapped the regenerating nerve fibers by their branching cytoplasmic processes. At the end of the third week, the flattened fibroblasts formed nearly continuous sheets in the subperineurial and perivascular spaces. Macrophages were frequently noticed between these cellular barrier-like sheets and in the subperineurial and perivascular spaces. Conclusion: it could be concluded that the endoneurial fibroblast-like cells form barrier-like cellular sheets that localized the endoneurial edema in the subperineurial and perivascular spaces and create also the endoneurial channel-like spaces containing degenerated myelin and endoneurial edema helping the resolution of such edema.

Keywords: sural nerve, endoneurial fibroblast-like cells, endoneurial edema, barrier-like and channel-like spaces

Procedia PDF Downloads 314
46 Pluripotent Stem Cells as Therapeutic Tools for Limbal Stem Cell Deficiencies and Drug Testing

Authors: Aberdam Edith, Sangari Linda, Petit Isabelle, Aberdam Daniel

Abstract:

Background and Rationale: Transparent avascularised cornea is essential for normal vision and depends on limbal stem cells (LSC) that reside between the cornea and the conjunctiva. Ocular burns or injuries may destroy the limbus, causing limbal stem cell deficiency (LSCD). The cornea becomes vascularised by invaded conjunctival cells, the stroma is scarring, resulting in corneal opacity and loss of vision. Grafted autologous limbus or cultivated autologous LCS can restore the vision, unless the two eyes are affected. Alternative cellular sources have been tested in the last decades, including oral mucosa or hair follicle epithelial cells. However, only partial success has been achieved by the use of these cells since they were not able to uniformly commit into corneal epithelial cells. Human pluripotent stem cells (iPSC) display both unlimited growth capacity and ability to differentiate into any cell type. Our goal was to design a standardized and reproducible protocol to produce transplantable autologous LSC from patients through cell reprogramming technology. Methodology: First, keratinocyte primary culture was established from a small number of plucked hair follicles of healthy donors. The resulting epithelial cells were reprogrammed into induced pluripotent stem cells (iPSCs) and further differentiate into corneal epithelial cells (CEC), according to a robust protocol that recapitulates the main step of corneal embryonic development. qRT-PCR analysis and immunofluorescent staining during the course of differentiation confirm the expression of stage specific markers of corneal embryonic lineage. First appear ectodermal progenitor-specific cytokeratins K8/K18, followed at day 7 by limbal-specific PAX6, TP63 and cytokeratins K5/K14. At day 15, K3/K12+-corneal cells are present. To amplify the iPSC-derived LSC (named COiPSC), intact small epithelial colonies were detached and cultivated in limbal cell-specific medium. In that culture conditions, the COiPSC can be frozen and thaw at any passage, while retaining their corneal characteristics for at least eight passages. To evaluate the potential of COiPSC as an alternative ocular toxicity model, COiPSC were treated at passage P0 to P4 with increasing amounts of SDS and Benzalkonium. Cell proliferation and apoptosis of treated cells was compared to LSC and the SV40-immortalized human corneal epithelial cell line (HCE) routinely used by cosmetological industrials. Of note, HCE are more resistant to toxicity than LSC. At P0, COiPSC were systematically more resistant to chemical toxicity than LSC and even to HCE. Remarkably, this behavior changed with passage since COiPSC at P2 became identical to LSC and thus closer to physiology than HCE. Comparative transcriptome analysis confirmed that COiPSC from P2 are similar to a mixture of LSC and CEC. Finally, by organotypic reconstitution assay, we demonstrated the ability of COiPSC to produce a 3D corneal epithelium on a stromal equivalent made of keratocytes. Conclusion: COiPSC could become valuable for two main applications: (1) an alternative robust tool to perform, in a reproducible and physiological manner, toxicity assays for cosmetic products and pharmacological tests of drugs. (2). COiPSC could become an alternative autologous source for cornea transplantation for LSCD.

Keywords: Limbal stem cell deficiency, iPSC, cornea, limbal stem cells

Procedia PDF Downloads 374
45 A Cross Cultural Study of Jewish and Arab Listeners: Perception of Harmonic Sequences

Authors: Roni Granot

Abstract:

Musical intervals are the building blocks of melody and harmony. Intervals differ in terms of their size, direction, or quality as consonants or dissonants. In Western music, perceptual dissonance is mostly associated with the sensation of beats or periodicity, whereas cognitive dissonance is associated with rules of harmony and voice leading. These two perceptions can be studied separately in musical cultures which include melodic with little or no harmonic structures. In the Arab musical system, there is a number of different quarter- tone intervals creating various combinations of consonant and dissonant intervals. While traditional Arab music includes only melody, today’s Arab pop music includes harmonization of songs, often using typical Western harmonic sequences. Therefore, the Arab population in Israel presents an interesting case which enables us to examine the distinction between perceptual and cognitive dissonance. In the current study, we compared the responses of 34 Jewish Western listeners and 56 Arab listeners to two types of stimuli and their relationships: Harmonic sequences and isolated harmonic intervals (dyads). Harmonic sequences were presented in synthesized piano tones and represented five levels of Harmonic prototypicality (Tonic ending; Tonic ending with half flattened third; Deceptive cadence; Half cadence; and Dissonant unrelated ending) and were rated on 5-point scales of closure and surprise. Here we report only findings related to the harmonic sequences. One-way repeated measures ANOVA with one within subjects factor with five levels (Type of sequence) and one between- subjects factor (Musical background) indicates a main effect of Type of sequence for surprise ratings F (4, 85) = 51 p<.001, and for closure ratings F (4, 78) 9.54 p < .001, no main effect of Background on either surprise or closure ratings, and a marginally significant Type X Background interaction for surprise F (4, 352) = 6.05 p = .069 and closure ratings F (4, 324) 3.89 p < .01). Planned comparisons show that the interaction of Type of sequence X Background center around surprise and closure ratings of the regular versus the half- flattened third tonic and the deceptive versus the half cadence. The half- flattened third tonic is rated as less surprising and as demanding less continuation than the regular tonic by the Arab listeners as compared to the Western listeners. In addition, the half cadence is rated as more surprising but demanding less continuation than the deceptive cadence in the Arab listeners as compared to the Western listeners. Together, our results suggest that despite the vast exposure of Arab listeners to Western harmony, sensitivity to harmonic rules seems to be partial with preference to oriental sonorities such as half flattened third. In addition, the percept of directionality which demands sensitivity to the level on which closure is obtained and which is strongly entrenched in Western harmony, may not be fully integrated into the Arab listeners’ mental harmonic scheme. Results will be discussed in terms of broad differences between Western and Eastern aesthetic ideals.

Keywords: harmony, cross cultural, Arab music, closure

Procedia PDF Downloads 246
44 The Morphological Changes of POV in Diabetic Patients and Its Correlation with Changes in Corneal Epithelium, Corneal Nerve, and the Fundus in Using Vivo Confocal Microscopy

Authors: Ji Jiazheng, Wang Jingrao, Jin Xin, Zhang Hong

Abstract:

Diabetes mellitus is a metabolic disease characterized by high blood sugar. A long-standing hyperglycemic state can lead to various tissue damage. Diabetic retinopathy is the most common and widely studied ocular complication and has become the leading cause of blindness in my country. At the same time, diabetes has profound clinically relevant effects on the cornea, leading to keratopathy and vision-threatening. The cornea is an avascular tissue and is sensitive to hyperglycemia, Keratopathy caused by diabetes is usually chronic, they are called diabetic keratopathy or diabetic neurotrophic keratopathy, leading to several diabetic corneal complications including delayed epithelial wound healing, recurrent erosions, neuropathy, loss of sensitivity. Corneal stem cell dysfunction in diabetic patients as an important influencing factor of diabetic keratopathy. The consequences of this condition are often underestimated. The limbus is located between the cornea and the sclera tissue. The limbal stroma consists of a series of radial elevations with fibrovascular centers known as palisades of Vogt (POV). Previous studies have shown that palisades of Vogt (POV), as the main site of limbal stem cells, plays an important role in the homeostasis of the corneal epithelium. Therefore, POV plays a vital role in the healing of corneal epithelial surgery and postoperative evaluation. IVCM can observe the condition of the corneal epithelium at the cellular level. It has profound significance and guidance for the evaluation of limbal and limbal stem cells. We have previously observed structural changes in POV in HSK and HZO patients on IVCM. At present, there have been reports involving limbal stem cell dysfunction in diabetic patients, but the specific pathogenesis is still unclear. However, there are no studies on POV morphological changes in patients with DM. Therefore, we performed statistics and compared the correlation between POV morphological changes and corneal epithelial basal cell density, corneal nerves, and length of disease in DM patients and normal humans using IVCM studies. At the same time, fundoscopy was used to observe the correlation between the thickness of RNFL and the thickness of GCC and POV in diabetic patients. And to observe the correlation between SVD, DVD and POV for research.

Keywords: confocal microscopy, fundus, limbal stem cells, diabetes

Procedia PDF Downloads 34
43 Phenotypic Diversity of the Tomato Germplasm from the Lazio Region in Central Italy, with a Case Study on Molecular Distinctiveness

Authors: Barbara Farinon, Maurizio E. Picarella, Lorenzo Mancini, Andrea Mazzucato

Abstract:

Italy is notoriously a secondary center of diversification for cultivated tomatoes (Solanum lycopersicum L.). The study of phenotypic and genetic diversity in landrace collections is important for germplasm conservation and biodiversity protection. Here, we set up to study the germplasm collected in the region of Lazio in Central Italy with a focus on the distinctiveness among landraces and the attribution of membership to unnamed accessions. Our regional collection included 30 accessions belonging to six different locally recognized landraces and 21 unnamed accessions. All accessions were gathered in Lazio and belonged to the collection held at the Regional Agency for the Development and Innovation of Agriculture in Lazio (ARSIAL, in the application of the Regional Act n. 15/2000, funded by Lazio Rural Development Plan 2014 – 2020 Agro-environmental Measure, Action 10.2.1) and at the University of Tuscia. We included 13 control genotypes as references. The collection showed wide phenotypic variability for several traits, such as fruit weight (range 14-277 g), locule number (2-12), shape index (0.54-2.65), yield (0.24-3.08 kg/plant), and soluble solids (3.4-7.5 °B). A few landraces showed uncommon phenotypes, such as potato leaf, colorless fruit epidermis, or delayed ripening. Multivariate analysis of 25 cardinal phenotypic variables grouped the named varieties and allowed to assign of some of the unnamed to recognized groups. A case study for distinctiveness is presented for the flattened-ribbed types that presented overlapping distribution according to the phenotypic data. Molecular markers retrieved by previous studies revealed differences compared to the phenotyping clustering, indicating that the named varieties “Scatolone di Bolsena” and “Pantano Romanesco” belong to the Marmande group, together with the reference landrace from Tuscany “Costoluto Fiorentino”. Differently, the landrace “Spagnoletta di Formia e Gaeta” was clearly distinct from the former at the molecular level. Therefore, a genotypic analysis of the analyzed collection appears needed to better define the molecular distinctiveness among the flattened-ribbed accessions, as well as to properly attribute the membership group of the unnamed accessions.

Keywords: distinctiveness, flattened-ribbed fruits, regional landraces, tomato

Procedia PDF Downloads 91
42 Characterization of Optical Systems for Intraocular Projection

Authors: Charles Q. Yu, Victoria H. Fan, Ahmed F. Al-Qahtani, Ibraim Viera

Abstract:

Introduction: Over 12 million people are blind due to opacity of the cornea, the clear tissue forming the front of the eye. Current methods use plastic implants to produce a clear optical pathway into the eye but are limited by a high rate of complications. New implants utilizing completely inside-the-eye projection technology can overcome blindness due to scarring of the eye by producing images on the retina without need for a clear optical pathway into the eye and may be free of the complications of traditional treatments. However, the interior of the eye is a challenging location for the design of optical focusing systems which can produce a sufficiently high quality image. No optical focusing systems have previously been characterized for this purpose. Methods: 3 optical focusing systems for intraocular (inside the eye) projection were designed and then modeled with ray tracing software, including a pinhole system, a planoconvex, and an achromatic system. These were then constructed using off-the-shelf components and tested in the laboratory. Weight, size, magnification, depth of focus, image quality and brightness were characterized. Results: Image quality increased with complexity of system design, as did weight and size. A dual achromatic doublet optical system produced the highest image quality. The visual acuity equivalent achieved with this system was better than 20/200. Its weight was less than that of the natural human crystalline lens. Conclusions: We demonstrate for the first time that high quality images can be produced by optical systems sufficiently small and light to be implanted within the eye.

Keywords: focusing, projection, blindness, cornea , achromatic, pinhole

Procedia PDF Downloads 94
41 Smart Coating for Enhanced Corneal Healing via Delivering Progranulin

Authors: Dan Yan, Yunuo Zhang, Yuhan Huang, Weijie Ouyang

Abstract:

The cornea serves as a vital protective barrier for the eye; however, it is prone to injury and damage that can disrupt corneal epithelium and nerves, triggering inflammation. Therefore, understanding the biological effects and molecular mechanisms involved in corneal wound healing and identifying drugs targeting these pathways is crucial for researchers in this field. This study aimed to investigate the therapeutic potential of progranulin (PGRN) in treating corneal injuries. Our findings demonstrated that PGRN significantly enhanced corneal wound repair by accelerating corneal re-epithelialization and re-innervation. In vitro experiments with cultured epithelial cells and trigeminal ganglion cells further revealed that PGRN stimulated corneal epithelial cell proliferation and promoted axon growth in trigeminal ganglion cells. Through RNA-sequencing (RNA-seq) analysis and other experimental techniques, we discovered that PGRN exerted its healing effects by modulating the Wnt signaling pathway, which played a critical role in repairing epithelial cells and promoting axon regeneration in trigeminal neurons. Importantly, our study highlighted the anti-inflammatory properties of PGRN by inhibiting the NF-κB signaling pathway, leading to decreased infiltration of macrophages. In conclusion, our findings underscored the potential of PGRN in facilitating corneal wound healing by promoting corneal epithelial cell proliferation, trigeminal ganglion cell axon regeneration, and suppressing ocular inflammation. These results suggest that PGRN could potentially expedite the healing process and improve visual outcomes in patients with corneal injuries.

Keywords: cornea, wound healing, progranulin, corneal epithelial cells, trigeminal ganglion cells

Procedia PDF Downloads 13
40 Complicated Corneal Ulceration in Cats: Clinical Diagnosis and Surgical Management of 80 Cases

Authors: Khaled M. Ali, Ayman A. Mostafa, Soliman M. Soliman

Abstract:

Objectives: To describe the most common clinical and endoscopic findings associated with complicated corneal ulcers in cats, and to determine the short-term outcomes after surgical treatment of these cats. Animals Eighteen client-owned cats of different breeds (52 females and 28 males), ranging in age from 3 months to 6 years, with corneal ulcers. Procedures: Cats were clinically evaluated to initially determine the concurrent corneal abnormalities. Endoscopic examination was performed to determine the anterior and posterior segments abnormalities. Superficial and deep stromal ulcers were treated using conjunctival flap. Corneal sequestrum was treated by partial keratectomy and conjunctival flap. Anterior synechia was treated via peripheral iridectomy and separation of the adhesion between the iris and the inner cornea. Symblepharon was treated by removal of the adhered conjunctival membrane from the cornea. Incurable endophthalmitis was treated surgically by extirpation. Short-term outcomes after surgical managements of selected corneal abnormalities were then assessed clinically and endoscopically. Results: Deep stromal ulcer with descemetocele, endophthalmitis, symblepharon, corneal sequestration and anterior synechia with secondary glaucoma and corneal scarring were the most common complications of corneal ulcer. FHV-1 was a common etiologic factor of corneal ulceration. Persistent corneal scars of varying shape and size developed in cats with deep stromal ulcer, anterior synechia, and corneal sequestration. Conclusions: Domestic shorthaired and Persian cats were the most predisposed breeds to FHV-1 infection and subsequent corneal ulceration. Immediate management of patients with corneal ulcer would prevent serious complications. No age or sex predisposition to complicated corneal ulceration in cats.

Keywords: cats, complicated corneal ulceration, clinical, endoscopic diagnosis, FHV-1

Procedia PDF Downloads 250
39 Analysis of Control by Flattening of the Welded Tubes

Authors: Hannachi Med Tahar, H. Djebaili, B. Daheche

Abstract:

In this approach, we have tried to describe the flattening of welded tubes, and its experimental application. The test is carried out at the (National product processing company dishes and tubes production). Usually, the final products (tubes) undergo a series of non-destructive inspection online and offline welding, and obviously destructive mechanical testing (bending, flattening, flaring, etc.). For this and for the purpose of implementing the flattening test, which applies to the processing of round tubes in other forms, it took four sections of welded tubes draft (before stretching hot) and welded tubes finished (after drawing hot and annealing), it was also noted the report 'health' flattened tubes must not show or crack or tear. The test is considered poor if it reveals a lack of ductility of the metal.

Keywords: flattening, destructive testing, tube drafts, finished tube, Castem 2001

Procedia PDF Downloads 414
38 The Effect of Culture and Managerial Practices on Organizational Leadership Towards Performance

Authors: Anyia Nduka, Aslan Bin Amad Senin, Ayu Azrin Bte Abdul Aziz

Abstract:

A management practice characterised by a value chain as its relatively flexible culture is replacing the old bureaucratic model of organisational practice that was built on dominance. Using a management practice fruition paradigm, the study delves into the implications of organisational culture and leadership. Developing a theory of leadership called the “cultural model” of organisational leadership by explaining how the shift from bureaucracy to management practises altered the roles and interactions of leaders. This model is well-grounded in leadership theory, considering the concept's adaptability to different leadership ideologies. In organisations where operational procedures and borders are not clearly defined, hierarchies are flattened, and work collaborations are sometimes based on contracts rather than employment. This cultural model of organizational leadership is intended to be a useful tool for predicting how effectively a leader will perform.

Keywords: leadership, organizational culture, management practices, efficiency

Procedia PDF Downloads 37
37 Ocular Delivery of Charged Drugs Using Iontophoresis

Authors: Abraham J. Domb

Abstract:

Nearly every eye disorder and treatment of post operated eyes evolve around ocular drug delivery. Most ocular diseases are treated with repeated topical applications administered as eye drops. Various attempts have been made to improve drug bioavailability by increasing both the retention of the drug in the pre-corneal area and the penetration of the drug through the cornea. However, currently marketed products are associated with vision blurring, irritability, patient discomfort, toxicity, low drug bioavailability, manufacturing difficulties and inadequate aqueous stability. It has been suggested to use iontophoresis for the non-invasive delivery of drugs. The iontophoretic device is composed of a control panel, two electrodes, a cylindrical well for the insertion of a disposable hydrogel, and a disposable hydrogel pellet. The drug-loaded hydrogel is attached to a cylindrical well at the edge of the electrode of the device and placed onto the eye. The device applies a variable electrical current that can vary from 0.1 mA to 1.5 mA for pre-set periods from 10 seconds to 300 seconds. The iontophoretic device developed in the lab was found to be effective in the delivery of the drugs: gentamicin, water-soluble steroids, and various anticancer agents. When testing in rabbits for safety, the device was considered to be non-toxic and effective.

Keywords: iontophoresis, eye disorder, drug delivery, hydrogel

Procedia PDF Downloads 42
36 Sediment Patterns from Fluid-Bed Interactions: A Direct Numerical Simulations Study on Fluvial Turbulent Flows

Authors: Nadim Zgheib, Sivaramakrishnan Balachandar

Abstract:

We present results on the initial formation of ripples from an initially flattened erodible bed. We use direct numerical simulations (DNS) of turbulent open channel flow over a fixed sinusoidal bed coupled with hydrodynamic stability analysis. We use the direct forcing immersed boundary method to account for the presence of the sediment bed. The resolved flow provides the bed shear stress and consequently the sediment transport rate, which is needed in the stability analysis of the Exner equation. The approach is different from traditional linear stability analysis in the sense that the phase lag between the bed topology, and the sediment flux is obtained from the DNS. We ran 11 simulations at a fixed shear Reynolds number of 180, but for different sediment bed wavelengths. The analysis allows us to sweep a large range of physical and modelling parameters to predict their effects on linear growth. The Froude number appears to be the critical controlling parameter in the early linear development of ripples, in contrast with the dominant role of particle Reynolds number during the equilibrium stage.

Keywords: direct numerical simulation, immersed boundary method, sediment-bed interactions, turbulent multiphase flow, linear stability analysis

Procedia PDF Downloads 147
35 Xenografts: Successful Penetrating Keratoplasty Between Two Species

Authors: Francisco Alvarado, Luz Ramírez

Abstract:

Corneal diseases are one of the main causes of visual impairment and affect almost 4 million, and this study assesses the effects of deep anterior lamellar keratoplasty (DALK) with porcine corneal stroma and postoperative topical treatment with tacrolimus in patients with infectious keratitis. No patient was observed with clinical graft rejection. Among the cases: 2 were positive to fungal culture, 2 with Aspergillus and the other 8 cases were confirmed by bacteriological culture. Corneal diseases are one of the main causes of visual impairment and affect almost 4 million. This study assesses the effects of deep anterior lamellar keratoplasty (DALK) with porcine corneal stroma and postoperative topical treatment with tacrolimus in patients with infectious keratitis. Receiver bed diameters ranged from 7.00 to 9.00 mm. No incidents of Descemet's membrane perforation were observed during surgery. During the follow-up period, no corneal graft splitting, IOP increase, or intolerance to tacrolimus were observed. Deep anterior lamellar keratoplasty seems to be the best option to avoid xenograft rejection, and it could help new surgical techniques in humans.

Keywords: ophthalmology, cornea, corneal transplant, xenografts, surgical innovations

Procedia PDF Downloads 51
34 The Optimal Location of Brickforce in Brickwork

Authors: Sandile Daniel Ngidi

Abstract:

A brickforce is a product consisting of two main parallel wires joined by in-line welded cross wires. Embedded in the normal thickness of the brickwork joint, the wires are manufactured to a flattened profile to simplify location into the mortar joint without steel build-up problems at lap positions corners/junctions or when used in conjunction with wall ties. A brickforce has been in continuous use since 1918. It is placed in the cement between courses of bricks. Brickforce is used in every course of the foundations and every course above lintel height. Otherwise, brickforce is used every fourth course in between the foundations and lintel height or a concrete slab and lintel height. The brickforce strengthens and stabilizes the wall, especially if you are building on unstable ground. It provides brickwork increased resistance to tensional stresses. Brickforce uses high tensile steel wires, which can withstand high forces but with a very little stretch. This helps to keep crack widths to a minimum. Recently a debate has opened about the purpose of using brickforce in single-story buildings. The debate has been compounded by the fact that there is no consensus about the spacing of brickforce in brickwork or masonry. In addition, very little information had been published on the relative merits of using the same size of brickforce for the different atmospheric conditions in South Africa. This paper aims to compare different types of brickforce systems used in different countries. Conclusions are made to identify the point and location of brickforce that optimize the system.

Keywords: brickforce, masonry concrete, reinforcement, strengthening, wall panels

Procedia PDF Downloads 195
33 Structural and Histochemical Alterations in the Development of the Stigma in Vibirnum tinus

Authors: Aslihan Cetinbas Genc, Meral Unal

Abstract:

This study presents the structural and cytochemical alterations of stigma at the stages of pre-anthesis, anthesis and post-anthesis in Vibirnum tinus. Capitate stigma continues with a closed style. The receptive surface of stigma is composed of unicellular papillae which are short and flattened at pre-anthesis stage. The papillae in this stage have dense cytoplasm with small vacuoles and a centrally located nucleus. With the start of anthesis, the stigma widens, papillae lengthen and become cylindrical. At anthesis stage, vacuoles enlarge, and nucleus moves to the base of the cell. At post-anthesis stage, the boundaries of the papillae become less noticeable. As proved by Periodic Acid Schiff procedure, the cytoplasm of papillae is rich in insoluble polysaccharides at all stages of development but it becomes remarkable at post-anthesis, particularly at the sub-papillar area. Although there is no significant difference in the content of protein in all stages of the development, it is more abundant at post-anthesis stage, as in Coomassie Brillant Blue stained sections. The surface of papillae is covered by a cuticle which becomes thicker at post-anthesis, and it gives positive reaction with Sudan Black B and Auramine O. The cuticle is covered by a pellicle stained by Coomassie Brillant Blue, indicating dry type of stigma.

Keywords: develeopmental features, histochemistry, stigma, Vibirnum tinus

Procedia PDF Downloads 216