Search results for: deviation.
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1036

Search results for: deviation.

916 Spectrophotometric Determination of Phenylephrine Hydrochloride by Coupling with Diazotized 2,4-Dinitroaniline

Authors: Sulaiman Gafar Muhamad

Abstract:

A rapid spectrophotometric method for the micro-determination of phenylephrine-HCl (PHE) has been developed. The proposed method involves the coupling of phenylephrine-HCl with diazotized 2,4-dinitroaniline in alkaline medium at λmax 455 nm. Under the present optimum condition, Beer’s law was obeyed in the range of 1.0-20 μg/ml of PHE with molar absorptivity of 1.915 ×104 l. mol-1.cm-1, with a relative error of 0.015 and a relative standard deviation of 0.024%. The current method has been applied successfully to estimate phenylephrine-HCl in pharmaceutical preparations (nose drop and syrup).

Keywords: diazo-coupling, 2, 4-dinitroaniline, phenylephrine-HCl, spectrophotometry

Procedia PDF Downloads 223
915 A Method for Precise Vertical Position of the Implant When Using Computerized Surgical Guides and Bone Reduction

Authors: Abraham Finkelman

Abstract:

Computerized Surgical Guides have been proven to be a predictable way to perform dental implants, with a relatively high accuracy in comparison to a treatment plan. When using the CSG Bone supported, it allows us to make the necessary changes of the hard tissue prior to the implant placement and after the implant placement. The CSG gives us an accurate position for the drilling, and during the implant placement it allows us to alter the vertical position of the implant altering the final position of the abutment and avoiding any risk of any damage to the adjacent anatomical structures. Any Changes required to the bone level can be done prior to the fixation of the CSG using a reduction guide, which incur extra surgical fees and the need of a second surgical guide. Any changes of the bone level after the implant placement are at the risk of damaging the implant neck surface. The technique consists of a universal system that allows us to remove the excess bone around the implant sockets prior to the implant placement which then enables us to place the implant in the vertical position with accuracy as planned with the CSG. The systems consist of a hollow pin of different sizes and diameters. Depending on the implant system that we are using. Length sizes are from 6mm-16mm and a diameter of 2.6mm-4.8mm. Upon the completion of the drilling, the pin is then inserted into the implant socket-using the insertion tool. Once the insertion tool has unscrewed the pin, we can continue with the bone reduction. The bone reduction can be done using conventional methods upon the removal of all the excess bone around the pin. The insertion tool is then screwed into the pin and the pin is then removed. We now, have the new bone level at the crest of the implant socket which is our mark for the vertical position of the implant. In some cases, when we are locating the implant very close to anatomical structures, any form of deviation to the vertical position of the implant during the surgery, can cause damage to such anatomical structures, creating irreversible damages such as paresthesia or dysesthesia of the mandibular nerve. If we are planning for immediate loading and we have done our temporary restauration in base of our computerized plan, deviation in the vertical position of the implant will affect the position of the abutment, affecting the accuracy of the temporary prosthesis, extending the working time till we adapt the prosthesis to the new position.

Keywords: bone reduction, computer aided navigation, dental implant placement, surgical guides

Procedia PDF Downloads 305
914 Development of Family Quality of Life Scale for a Family Which Has a Person with Disability: Results of a Delphi Study

Authors: Thirakorn Maneerat, Darunee Jongudomkarn, Jiraporn Khiewyoo

Abstract:

Family quality of life of families who have persons with disabilities is a core concern in government services and community health promotion to deal with the multidimensionality of today’s health and societal issues. The number of families who have persons with disabilities in Thailand is gradually increasing. However, facilitation and evaluation of such family quality of life are limited by the lack of feasible tools. As a consequence, service provided for the families is not optimally facilitated and evaluated. This paper is part of a larger project which is aimed to develop a scale for measuring of family quality of life of families who have persons with developmental disabilities in Thailand, presenting the results of a three-round Delphi method involving 11 experts. The study was obtained during December 2013 to May 2014. The first round consisted of open-ended questionnaire and content analysis of the answers. The second round comprised a 5-point Likert scale structured questionnaire based on the first round analysis, with required the experts to identify the most relevant studied tool aspects. Their feedbacks levels of agreements were statistic analysis using the median, interquartile range and quartile deviation. The included criteria for items acceptance were greater than 3.50 of the median, lesser than 1.50 of interquartile range, and 0.65 or less of a quartile deviation. Finally, the proposed questionnaire was structured and validated by the experts in the third round. The results found that across all three rounds, the experts achieved 100% agreement on the five factors regarding to quality of life of a family who have person with disability were considered. These five factors with 38 items were included: 1) 10 items of family interactions; 2) 9 items of child rearing; 3) 7 items of physical and material resources; 4) 5 items of social-emotional status; and 7 items of disability-related services and welfare. Next step of the study was examined the construct validity by using factor analysis methods.

Keywords: tool development, family quality of life scale, person with disability, Delphi study

Procedia PDF Downloads 323
913 A Safety-Door for Earthquake Disaster Prevention - Part II

Authors: Daniel Y. Abebe, Jaehyouk Choi

Abstract:

The safety of door has not given much attention. The main problem of doors during and after earthquake is that they are unable to be opened because deviation from its original position by the lateral load. The aim of this research is to develop and evaluate a safety door that keeps the door frame in its original position or keeps its edge angles perpendicular during and post-earthquake. Nonlinear finite element analysis was conducted in order to evaluate the structural performance and behavior of the proposed door under both monotonic and cyclic loading.

Keywords: safety-door, earthquake disaster, low yield point steel, passive energy dissipating device, FE analysis

Procedia PDF Downloads 429
912 An Association Model to Correlate the Experimentally Determined Mixture Solubilities of Methyl 10-Undecenoate with Methyl Ricinoleate in Supercritical Carbon Dioxide

Authors: V. Mani Rathnam, Giridhar Madras

Abstract:

Fossil fuels are depleting rapidly as the demand for energy, and its allied chemicals are continuously increasing in the modern world. Therefore, sustainable renewable energy sources based on non-edible oils are being explored as a viable option as they do not compete with the food commodities. Oils such as castor oil are rich in fatty acids and thus can be used for the synthesis of biodiesel, bio-lubricants, and many other fine industrial chemicals. There are several processes available for the synthesis of different chemicals obtained from the castor oil. One such process is the transesterification of castor oil, which results in a mixture of fatty acid methyl esters. The main products in the above reaction are methyl ricinoleate and methyl 10-undecenoate. To separate these compounds, supercritical carbon dioxide (SCCO₂) was used as a green solvent. SCCO₂ was chosen as a solvent due to its easy availability, non-toxic, non-flammable, and low cost. In order to design any separation process, the preliminary requirement is the solubility or phase equilibrium data. Therefore, the solubility of a mixture of methyl ricinoleate with methyl 10-undecenoate in SCCO₂ was determined in the present study. The temperature and pressure range selected for the investigation were T = 313 K to 333 K and P = 10 MPa to 18 MPa. It was observed that the solubility (mol·mol⁻¹) of methyl 10-undecenoate varied from 2.44 x 10⁻³ to 8.42 x 10⁻³ whereas it varied from 0.203 x 10⁻³ to 6.28 x 10⁻³ for methyl ricinoleate within the chosen operating conditions. These solubilities followed a retrograde behavior (characterized by the decrease in the solubility values with the increase in temperature) throughout the range of investigated operating conditions. An association theory model, coupled with regular solution theory for activity coefficients, was developed in the present study. The deviation from the experimental data using this model can be quantified using the average absolute relative deviation (AARD). The AARD% for the present compounds is 4.69 and 8.08 for methyl 10-undecenoate and methyl ricinoleate, respectively in a mixture of methyl ricinoleate and methyl 10-undecenoate. The maximum solubility enhancement of 32% was observed for the methyl ricinoleate in a mixture of methyl ricinoleate and methyl 10-undecenoate. The highest selectivity of SCCO₂ was observed to be 12 for methyl 10-undecenoate in a mixture of methyl ricinoleate and methyl 10-undecenoate.

Keywords: association theory, liquid mixtures, solubilities, supercritical carbon dioxide

Procedia PDF Downloads 103
911 Understanding and Political Participation in Constitutional Monarchy of Dusit District Residents

Authors: Sudaporn Arundee

Abstract:

The purposes of this research were to study in three areas: (1) to study political understanding and participating of the constitutional monarchy, (2) to study the level of participation. This paper drew upon data collected from 395 Dusit residents by using questionnaire. In addition, a simple random sampling was utilized to collect data. The findings revealed that 94 percent of respondents had a very good understanding of constitution monarchy with a mean of 4.8. However, the respondents overall had a very low level of participation with the mean score of 1.69 and standard deviation of .719.

Keywords: political participation, constitutional monarchy, management and social sciences

Procedia PDF Downloads 224
910 Determination of Four Anions in the Ground Layer of Tomb Murals by Ion Chromatography

Authors: Liping Qiu, Xiaofeng Zhang

Abstract:

The ion chromatography method for the rapid determination of four anions (F⁻、Cl⁻、SO₄²⁻、NO₃⁻) in burial ground poles was optimized. The L₉(₃⁴) orthogonal test was used to determine the optimal parameters of sample pretreatment: accurately weigh 2.000g of sample, add 10mL of ultrapure water, and extract for 40min under the conditions of shaking temperature 40℃ and shaking speed 180 r·min-1. The eluent was 25 mmol/L KOH solution, the analytical column was Ion Pac® AS11-SH (250 mm × 4.0 mm), and the purified filtrate was measured by a conductivity detector. Under this method, the detection limit of each ion is 0.066~0.078mg/kg, the relative standard deviation is 0.86%~2.44% (n=7), and the recovery rate is 94.6~101.9.

Keywords: ion chromatography, tomb, anion (F⁻, Cl⁻, SO₄²⁻, NO₃⁻), environmental protection

Procedia PDF Downloads 67
909 Approximate-Based Estimation of Single Event Upset Effect on Statistic Random-Access Memory-Based Field-Programmable Gate Arrays

Authors: Mahsa Mousavi, Hamid Reza Pourshaghaghi, Mohammad Tahghighi, Henk Corporaal

Abstract:

Recently, Statistic Random-Access Memory-based (SRAM-based) Field-Programmable Gate Arrays (FPGAs) are widely used in aeronautics and space systems where high dependability is demanded and considered as a mandatory requirement. Since design’s circuit is stored in configuration memory in SRAM-based FPGAs; they are very sensitive to Single Event Upsets (SEUs). In addition, the adverse effects of SEUs on the electronics used in space are much higher than in the Earth. Thus, developing fault tolerant techniques play crucial roles for the use of SRAM-based FPGAs in space. However, fault tolerance techniques introduce additional penalties in system parameters, e.g., area, power, performance and design time. In this paper, an accurate estimation of configuration memory vulnerability to SEUs is proposed for approximate-tolerant applications. This vulnerability estimation is highly required for compromising between the overhead introduced by fault tolerance techniques and system robustness. In this paper, we study applications in which the exact final output value is not necessarily always a concern meaning that some of the SEU-induced changes in output values are negligible. We therefore define and propose Approximate-based Configuration Memory Vulnerability Factor (ACMVF) estimation to avoid overestimating configuration memory vulnerability to SEUs. In this paper, we assess the vulnerability of configuration memory by injecting SEUs in configuration memory bits and comparing the output values of a given circuit in presence of SEUs with expected correct output. In spite of conventional vulnerability factor calculation methods, which accounts any deviations from the expected value as failures, in our proposed method a threshold margin is considered depending on user-case applications. Given the proposed threshold margin in our model, a failure occurs only when the difference between the erroneous output value and the expected output value is more than this margin. The ACMVF is subsequently calculated by acquiring the ratio of failures with respect to the total number of SEU injections. In our paper, a test-bench for emulating SEUs and calculating ACMVF is implemented on Zynq-7000 FPGA platform. This system makes use of the Single Event Mitigation (SEM) IP core to inject SEUs into configuration memory bits of the target design implemented in Zynq-7000 FPGA. Experimental results for 32-bit adder show that, when 1% to 10% deviation from correct output is considered, the counted failures number is reduced 41% to 59% compared with the failures number counted by conventional vulnerability factor calculation. It means that estimation accuracy of the configuration memory vulnerability to SEUs is improved up to 58% in the case that 10% deviation is acceptable in output results. Note that less than 10% deviation in addition result is reasonably tolerable for many applications in approximate computing domain such as Convolutional Neural Network (CNN).

Keywords: fault tolerance, FPGA, single event upset, approximate computing

Procedia PDF Downloads 156
908 Effectiveness of Medication and Non-Medication Therapy on Working Memory of Children with Attention Deficit and Hyperactivity Disorder

Authors: Mohaammad Ahmadpanah, Amineh Akhondi, Mohammad Haghighi, Ali Ghaleiha, Leila Jahangard, Elham Salari

Abstract:

Background: Working memory includes the capability to keep and manipulate information in a short period of time. This capability is the basis of complicated judgments and has been attended to as the specific and constant character of individuals. Children with attention deficit and hyperactivity are among the people suffering from deficiency in the active memory, and this deficiency has been attributed to the problem of frontal lobe. This study utilizes a new approach with suitable tasks and methods for training active memory and assessment of the effects of the trainings. Participants: The children participating in this study were of 7-15 year age, who were diagnosed by the psychiatrist and psychologist as hyperactive and attention deficit based on DSM-IV criteria. The intervention group was consisted of 8 boys and 6 girls with the average age of 11 years and standard deviation of 2, and the control group was consisted of 2 girls and 5 boys with an average age of 11.4 and standard deviation of 3. Three children in the test group and two in the control group were under medicinal therapy. Results: Working memory training meaningfully improved the performance in not-trained areas as visual-spatial working memory as well as the performance in Raven progressive tests which are a perfect example of non-verbal, complicated reasoning tasks. In addition, motional activities – measured based on the number of head movements during computerized measuring program – was meaningfully reduced in the medication group. The results of the second test showed that training similar exercise to teenagers and adults results in the improvement of cognition functions, as in hyperactive people. Discussion: The results of this study showed that the performance of working memory is improved through training, and these trainings are extended and generalized in other areas of cognition functions not receiving any training. Trainings resulted in the improvement of performance in the tasks related to prefrontal. They had also a positive and meaningful impact on the moving activities of hyperactive children.

Keywords: attention deficit hyperactivity disorder, working memory, non-medical treatment, children

Procedia PDF Downloads 337
907 Evaluation of the Efficacy and Tolerance of Gabapentin in the Treatment of Neuropathic Pain

Authors: A. Ibovi Mouondayi, S. Zaher, R. Assadi, K. Erraoui, S. Sboul, J. Daoudim, S. Bousselham, K. Nassar, S. Janani

Abstract:

INTRODUCTION: Neuropathic pain (NP) caused by damage to the somatosensory nervous system has a significant impact on quality of life and is associated with a high economic burden on the individual and society. The treatment of neuropathic pain consists of the use of a wide range of therapeutic agents, including gabapentin, which is used in the treatment of neuropathic pain. OBJECTIF: The objective of this study was to evaluate the efficacy and tolerance of gabapentin in the treatment of neuropathic pain. MATERIAL AND METHOD: This is a monocentric, cross-sectional, descriptive, retrospective study conducted in our department over a period of 19 months from October 2020 to April 2022. The missing parameters were collected during phone calls of the patients concerned. The diagnostic tool adopted was the DN4 questionnaire in the dialectal Arabic version. The impact of NP was assessed by the visual analog scale (VAS) on pain, sleep, and function. The impact of PN on mood was assessed by the "Hospital anxiety, and depression scale HAD" score in the validated Arabic version. The exclusion criteria were patients followed up for depression and other psychiatric pathologies. RESULTS: A total of 67 patients' data were collected. The average age was 64 years (+/- 15 years), with extremes ranging from 26 years to 94 years. 58 women and 9 men with an M/F sex ratio of 0.15. Cervical radiculopathy was found in 21% of this population, and lumbosacral radiculopathy in 61%. Gabapentin was introduced in doses ranging from 300 to 1800 mg per day with an average dose of 864 mg (+/- 346) per day for an average duration of 12.6 months. Before treatment, 93% of patients had a non-restorative sleep quality (VAS>3). 54% of patients had a pain VAS greater than 5. The function was normal in only 9% of patients. The mean anxiety score was 3.25 (standard deviation: 2.70), and the mean HAD depression score was 3.79 (standard deviation: 1.79). After treatment, all patients had improved the quality of their sleep (p<0.0001). A significant difference was noted in pain VAS, function, as well as anxiety and depression, and HAD score. Gabapentin was stopped for side effects (dizziness and drowsiness) and/or unsatisfactory response. CONCLUSION: Our data demonstrate a favorable effect of gabapentin on the management of neuropathic pain with a significant difference before and after treatment on the quality of life of patients associated with an acceptable tolerance profile.

Keywords: neuropathic pain, chronic pain, treatment, gabapentin

Procedia PDF Downloads 71
906 Reliability-Based Life-Cycle Cost Model for Engineering Systems

Authors: Reza Lotfalian, Sudarshan Martins, Peter Radziszewski

Abstract:

The effect of reliability on life-cycle cost, including initial and maintenance cost of a system is studied. The failure probability of a component is used to calculate the average maintenance cost during the operation cycle of the component. The standard deviation of the life-cycle cost is also calculated as an error measure for the average life-cycle cost. As a numerical example, the model is used to study the average life cycle cost of an electric motor.

Keywords: initial cost, life-cycle cost, maintenance cost, reliability

Procedia PDF Downloads 561
905 Dosimetric Comparison of Conventional Plans versus Three Dimensional Conformal Simultaneously Integrated Boost Plans

Authors: Shoukat Ali, Amjad Hussain, Latif-ur-Rehman, Sehrish Inam

Abstract:

Radiotherapy plays an important role in the management of cancer patients. Approximately 50% of the cancer patients receive radiotherapy at one point or another during the course of treatment. The entire radiotherapy treatment of curative intent is divided into different phases, depending on the histology of the tumor. The established protocols are useful in deciding the total dose, fraction size, and numbers of phases. The objective of this study was to evaluate the dosimetric differences between the conventional treatment protocols and the three-dimensional conformal simultaneously integrated boost (SIB) plans for three different tumors sites (i.e. bladder, breast, and brain). A total of 30 patients with brain, breast and bladder cancers were selected in this retrospective study. All the patients were CT simulated initially. The primary physician contoured PTV1 and PTV2 in the axial slices. The conventional doses prescribed for brain and breast is 60Gy/30 fractions, and 64.8Gy/36 fractions for bladder treatment. For the SIB plans biological effective doses (BED) were calculated for 25 fractions. The two conventional (Phase I and Phase II) and a single SIB plan for each patient were generated on Eclipse™ treatment planning system. Treatment plans were compared and analyzed for coverage index, conformity index, homogeneity index, dose gradient and organs at risk doses.In both plans 95% of PTV volume received a minimum of 95% of the prescribe dose. Dose deviation in the optic chiasm was found to be less than 0.5%. There is no significant difference in lung V20 and heart V30 in the breast plans. In the rectum plans V75%, V50% and V25% were found to be less than 1.2% different. Deviation in the tumor coverage, conformity and homogeneity indices were found to be less than 1%. SIB plans with three dimensional conformal radiotherapy technique reduce the overall treatment time without compromising the target coverage and without increasing dose to the organs at risk. The higher dose per fraction may increase the late effects to some extent. Further studies are required to evaluate the late effects with the intention of standardizing the SIB technique for practical implementation.

Keywords: coverage index, conformity index, dose gradient, homogeneity index, simultaneously integrated boost

Procedia PDF Downloads 448
904 Viability of EBT3 Film in Small Dimensions to Be Use for in-Vivo Dosimetry in Radiation Therapy

Authors: Abdul Qadir Jangda, Khadija Mariam, Usman Ahmed, Sharib Ahmed

Abstract:

The Gafchromic EBT3 film has the characteristic of high spatial resolution, weak energy dependence and near tissue equivalence which makes them viable to be used for in-vivo dosimetry in External Beam and Brachytherapy applications. The aim of this study is to assess the smallest film dimension that may be feasible for the use in in-vivo dosimetry. To evaluate the viability, the film sizes from 3 x 3 mm to 20 x 20 mm were calibrated with 6 MV Photon and 6 MeV electron beams. The Gafchromic EBT3 (Lot no. A05151201, Make: ISP) film was cut into five different sizes in order to establish the relationship between absorbed dose vs. film dimensions. The film dimension were 3 x 3, 5 x 5, 10 x 10, 15 x 15, and 20 x 20 mm. The films were irradiated on Varian Clinac® 2100C linear accelerator for dose range from 0 to 1000 cGy using PTW solid water phantom. The irradiation was performed as per clinical absolute dose rate calibratin setup, i.e. 100 cm SAD, 5.0 cm depth and field size of 10x10 cm2 and 100 cm SSD, 1.4 cm depth and 15x15 cm2 applicator for photon and electron respectively. The irradiated films were scanned with the landscape orientation and a post development time of 48 hours (minimum). Film scanning accomplished using Epson Expression 10000 XL Flatbed Scanner and quantitative analysis carried out with ImageJ freeware software. Results show that the dose variation with different film dimension ranging from 3 x 3 mm to 20 x 20 mm is very minimal with a maximum standard deviation of 0.0058 in Optical Density for a dose level of 3000 cGy and the the standard deviation increases with the increase in dose level. So the precaution must be taken while using the small dimension films for higher doses. Analysis shows that there is insignificant variation in the absorbed dose with a change in film dimension of EBT3 film. Study concludes that the film dimension upto 3 x 3 mm can safely be used up to a dose level of 3000 cGy without the need of recalibration for particular dimension in use for dosimetric application. However, for higher dose levels, one may need to calibrate the films for a particular dimension in use for higher accuracy. It was also noticed that the crystalline structure of the film got damage at the edges while cutting the film, which can contribute to the wrong dose if the region of interest includes the damage area of the film

Keywords: external beam radiotherapy, film calibration, film dosimetery, in-vivo dosimetery

Procedia PDF Downloads 461
903 Comparison Serum Vitamin D by Geographic between the Highland and Lowland Schizophrenic Patient in the Sumatera Utara

Authors: Novita Linda Akbar, Elmeida Effendy, Mustafa M. Amin

Abstract:

Background: The most common of psychotic disorders is schizophrenia. Vitamin D is made from sunlight, and in the skin from UVB radiation from sunlight. If people with Vitamin D deficiency is common severe mental illness such as schizophrenia.Schizophrenia is a chronic mental illness characterised by positive symptoms and negatives symptoms, such as hallucinations and delusions, flat affect and lack of motivation we can found. In patients with Schizophrenia maybe have several environmental risk factors for schizophrenia, such as season of birth, latitude, and climate has been linked to vitamin D deficiency. There is also relationship between the risk of schizophrenia and latitude, and with an increased incidence rate of schizophrenia seen at a higher latitude. Methods: This study was an analytical study, conducted in BLUD RS Jiwa Propinsi Sumatera Utara and RSUD Deli Serdang, the period in May 2016 and ended in June 2016 with a sample of the study 60 sample (20 patients live in the Highland and Lowland, 20 healthy controls). Inclusion criteria were schizophrenic patients both men and women, aged between 18 to 60 years old, acute phase no agitation or abstinence antipsychotic drugs for two weeks, live in the Highland and Lowland, and willing to participate this study. Exclusion criteria were history of other psychotic disorders, comorbidities with other common medical condition, a history of substance abuse. Sample inspection for serum vitamin D using ELFA method. Statistical analysis using numeric comparative T-independent test. Results: The results showed that average levels of vitamin D for a group of subjects living in areas of high land was 227.6 ng / mL with a standard deviation of 86.78 ng / mL, the lowest levels of vitamin D is 138 ng / mL and the highest 482 ng / mL. In the group of subjects who settled in the low lands seem mean vitamin D levels higher than the mountainous area with an average 237.8 ng / mL with a standard deviation of 100.16 ng / mL. Vitamin D levels are lowest and the highest 138-585 ng / mL. Conclusion and Suggestion: The results of the analysis using the Mann Whitney test showed that there were no significant differences between the mean for the levels of vitamin D based on residence subject with a value of p = 0.652.

Keywords: latitude, schizophrenia, Vitamin D, Sumatera Utara

Procedia PDF Downloads 220
902 Voltage and Frequency Regulation Using the Third-Party Mid-Size Battery

Authors: Roghieh A. Biroon, Zoleikha Abdollahi

Abstract:

The recent growth of renewables, e.g., solar panels, batteries, and electric vehicles (EVs) in residential and small commercial sectors, has potential impacts on the stability and operation of power grids. Considering approximately 50 percent share of the residential and the commercial sectors in the electricity demand market, the significance of these impacts, and the necessity of addressing them are more highlighted. Utilities and power system operators should manage the renewable electricity sources integration with power systems in such a way to extract the most possible advantages for the power systems. The most common effect of high penetration level of the renewables is the reverse power flow in the distribution feeders when the customers generate more power than their needs. The reverse power flow causes voltage rise and thermal issues in the power grids. To overcome the voltage rise issues in the distribution system, several techniques have been proposed including reducing transformers short circuit resistance and feeder impedance, installing autotransformers/voltage regulators along the line, absorbing the reactive power by distributed generators (DGs), and limiting the PV and battery sizes. In this study, we consider a medium-scale battery energy storage to manage the power energy and address the aforementioned issues on voltage deviation and power loss increase. We propose an optimization algorithm to find the optimum size and location for the battery. The optimization for the battery location and size is so that the battery maintains the feeder voltage deviation and power loss at a certain desired level. Moreover, the proposed optimization algorithm controls the charging/discharging profile of the battery to absorb the negative power flow from residential and commercial customers in the feeder during the peak time and sell the power back to the system during the off-peak time. The proposed battery regulates the voltage problem in the distribution system while it also can play frequency regulation role in islanded microgrids. This battery can be regulated and controlled by the utilities or a third-party ancillary service provider for the utilities to reduce the power system loss and regulate the distribution feeder voltage and frequency in standard level.

Keywords: ancillary services, battery, distribution system and optimization

Procedia PDF Downloads 106
901 Climate Changes Impact on Artificial Wetlands

Authors: Carla Idely Palencia-Aguilar

Abstract:

Artificial wetlands play an important role at Guasca Municipality in Colombia, not only because they are used for the agroindustry, but also because more than 45 species were found, some of which are endemic and migratory birds. Remote sensing was used to determine the changes in the area occupied by water of artificial wetlands by means of Aster and Modis images for different time periods. Evapotranspiration was also determined by three methods: Surface Energy Balance System-Su (SEBS) algorithm, Surface Energy Balance- Bastiaanssen (SEBAL) algorithm, and Potential Evapotranspiration- FAO. Empirical equations were also developed to determine the relationship between Normalized Difference Vegetation Index (NDVI) versus net radiation, ambient temperature and rain with an obtained R2 of 0.83. Groundwater level fluctuations on a daily basis were studied as well. Data from a piezometer placed next to the wetland were fitted with rain changes (with two weather stations located at the proximities of the wetlands) by means of multiple regression and time series analysis, the R2 from the calculated and measured values resulted was higher than 0.98. Information from nearby weather stations provided information for ordinary kriging as well as the results for the Digital Elevation Model (DEM) developed by using PCI software. Standard models (exponential, spherical, circular, gaussian, linear) to describe spatial variation were tested. Ordinary Cokriging between height and rain variables were also tested, to determine if the accuracy of the interpolation would increase. The results showed no significant differences giving the fact that the mean result of the spherical function for the rain samples after ordinary kriging was 58.06 and a standard deviation of 18.06. The cokriging using for the variable rain, a spherical function; for height variable, the power function and for the cross variable (rain and height), the spherical function had a mean of 57.58 and a standard deviation of 18.36. Threatens of eutrophication were also studied, given the unconsciousness of neighbours and government deficiency. Water quality was determined over the years; different parameters were studied to determine the chemical characteristics of water. In addition, 600 pesticides were studied by gas and liquid chromatography. Results showed that coliforms, nitrogen, phosphorous and prochloraz were the most significant contaminants.

Keywords: DEM, evapotranspiration, geostatistics, NDVI

Procedia PDF Downloads 88
900 Numerical Simulation of the Fractional Flow Reserve in the Coronary Artery with Serial Stenoses of Varying Configuration

Authors: Mariia Timofeeva, Andrew Ooi, Eric K. W. Poon, Peter Barlis

Abstract:

Atherosclerotic plaque build-up, commonly known as stenosis, limits blood flow and hence oxygen and nutrient supplies to the heart muscle. Thus, assessment of its severity is of great interest to health professionals. Numerical simulation of the fractional flow reserve (FFR) has proved to be well correlated with invasively measured FFR used for physiological assessment of the severity of coronary stenosis in arteries. Atherosclerosis may impact the diseased artery in several locations causing serial stenoses, which is a complicated subset of coronary artery disease that requires careful treatment planning. However, hemodynamic of the serial sequential stenoses in coronary arteries has not been extensively studied. The hemodynamics of the serial stenoses is complex because the stenoses in the series interact and affect the flow through each other. To address this, serial stenoses in a 3.4 mm left anterior descending (LAD) artery are examined in this study. Two diameter stenoses (DS) are considered, 30 and 50 percent of the reference diameter. Serial stenoses configurations are divided into three groups based on the order of the stenoses in the series, spacing between them, and deviation of the stenoses’ symmetry (eccentricity). A patient-specific pulsatile waveform is used in the simulations. Blood flow within the stenotic artery is assumed to be laminar, Newtonian, and incompressible. Results for the FFR are reported. Based on the simulation results, it can be deduced that the larger drop in pressure (smaller value of the FFR) is expected when the percentage of the second stenosis in the series is bigger. Varying the distance between the stenoses affects the location of the maximum drop in the pressure, while the minimal FFR in the artery remains unchanged. Eccentric serial stenoses are characterized by a noticeably larger decrease in pressure through the stenoses and by the development of the chaotic flow downstream of the stenoses. The largest drop in the pressure (about 4% difference compared to the axisymmetric case) is obtained for the serial stenoses, where both the stenoses are highly eccentric with the centerlines deflected to the different sides of the LAD. In conclusion, varying configuration of the sequential serial stenoses results in a different distribution of FFR through the LAD. Results presented in this study provide insight into the clinical assessment of the severity of the coronary serial stenoses, which is proved to depend on the relative position of the stenoses and the deviation of the stenoses’ symmetry.

Keywords: computational fluid dynamics, coronary artery, fractional flow reserve, serial stenoses

Procedia PDF Downloads 157
899 Characteristics Influencing Response of a Base Isolated Building

Authors: Ounis Hadj Mohamed, Ounis Abdelhafid

Abstract:

In order to illustrate the effect of damping on the response of a base-isolated building, a parametric study is led, taking into account the progressive variation of the damping ratio (10% to 30%) under different types of seismic excitations (near and far field). A time history analysis is used to determine the response of the structure in terms of relative displacement and understory drift at various levels of the building. Thus, the results show that the efficiency of the isolator increases with the assumed damping ratio, provided that this latter is less or equal to 20%. Beyond this value, the isolator becomes less convenient. Furthermore, a strong deviation of energy capacity by the LRB (Lead Rubber Bearing) system is recorded.

Keywords: damping, base isolation, LRB, seismic excitation, hysteresis

Procedia PDF Downloads 386
898 Detection of Polymorphism of Growth Hormone Gene in Holstein Cattle

Authors: Emine Şahin, Murat Soner Balcıoğlu

Abstract:

The aim of this study was to determine the growth hormone (bGH) gene polymorphism in the Holstein cattle growing around Antalya in Turkey. In order to determine the bGH-AluI polymorphism, polymerase chain reaction - restriction fragment length polymorphism (PCR-RFLP) method was performed. A 891 bp fragment of bGH was amplified and two types of alleles C and D for bGH were observed. In this study, the frequencies of C and D alleles were 0.8438 and 0.1562, respectively. The genotype frequencies for CC, CD and DD were 0.787, 0.191 and 0.022, respectively. According to the results of the chi-square test, a significant deviation from the Hardy-Weinberg equilibrium was not determined for the bGH locus in the population.

Keywords: Growth Hormone Gene, Holstein , Polymorphism, RFLP

Procedia PDF Downloads 339
897 Prevalence of Anxiety among End Stage Renal Disease Patients and Its Association with Patient Compliance to Hemodialysis and Physician Instructions

Authors: Mohammed Asiri, Saleh Alsuwayt, Mohammed Bin Mugren, Abdulmalik Almufarrih, Tariq Alotaibi, Saad Almodameg

Abstract:

Background: End-stage renal disease is a major public health concern with high incidence and mortality rate. Most of ESRD patients are on hemodialysis therapy which is a long-term treatment that disturbs patients’ lifestyle. As a result, he will be susceptible to develop psychiatric disorders like anxiety that may direct him to non-compliance on physician instructions and hemodialysis therapy. Although there are studies conducted on psychiatric issues in hemodialysis patients, but few studies focused on the effect of anxiety disorder and the patient’s compliance. Hence, we are interested in determining the prevalence of anxiety disorder among hemodialysis patients in Saudi Arabia, as well as in defining the correlation between anxiety disorder and compliance on physician instructions and hemodialysis therapy. We hypothesize that our study will show a higher prevalence of anxiety in hemodialysis patients than in general population. Also, we expect the anxiety to have a negative impact on their compliance. Methodology: We used a cross-sectional study design carried out at dialysis unit of four major hospitals in Riyadh, KSA. We interviewed 235 End Stage Renal Disease male and female patients who are on hemodialysis. We divided the patients into two categories according to their compliance. we used modified general questionnaire to get their demographic data, then we used a psychometric response scale called visual analog scale (VAS) to assess patient’s compliance to hemodialysis and physician’s instructions. Also, we used the Arabic validated version of the hospital anxiety and depression scale (HAD scale) used mainly for anxiety assessment. Results: The overall response rate was 54%. Respondents included 147 (62.6%) males and 88 (37.4%) females. The prevalence of anxiety among hemodialysis patients is 13.3%. According to visual analog scale, we found that 189 compliant patients and 45 non-compliant patients. For HAD scale, the mean ± standard deviation of the total score for females was (4.44 ± 4.7) and it’s higher than males which was 2.65 ± 3.08 (P-value= 0.002). The mean ± standard deviation of HAD score in the non-compliant group was (5.88  4.88) and it was higher than the compliant group (2.7  3.32) (P-value= 0.004). Among non-complaint group, 33.3% of anxious patients were males and 66.6% were females. There was a negative correlation between HAD score of anxiety and visual analog scale (R= - 0.285). Conclusion: We conclude that there is a high prevalence of anxiety among patients with End Stage Renal Disease that was higher in females with association of non-compliance to physician’s instructions and hemodialysis therapy.

Keywords: anxiety, end-stage renal disease, renal failure, anxiety disorder

Procedia PDF Downloads 241
896 Evaluation of the Irritation Potential of Three Topical Formulations of Minoxidil 5% Using Patch Test

Authors: Sule Pallavi, Shah Priyank, Thavkar Amit, Mehta Suyog, Rohira Poonam

Abstract:

Minoxidil is used topically to help hair growth in the treatment of male androgenetic alopecia. The objective of this study is to compare irritation potential of three conventional formulation of minoxidil 5% topical solution of in human patch test. The study was a single centre, double blind, non-randomized controlled study in 56 healthy adult Indian subjects. Occlusive patch test for 24 hours was performed with three formulation of minoxidil 5% topical solution. Products tested included aqueous based minoxidil 5% (AnasureTM 5%, Sun Pharma, India – Brand A), alcohol based minoxidil 5% (Brand B) and aqueous based minoxidil 5% (Brand C). Isotonic saline 0.9% and 1% w/w sodium lauryl sulphate were included as negative control and positive control respectively. Patches were applied and removed after 24hours. The skin reaction was assessed and clinically scored 24 hours after the removal of the patches under constant artificial daylight source using Draize scale (0-4 points scale for erythema/wrinkles/dryness and for oedema). A combined mean score up to 2.0/8.0 indicates a product is “non-irritant” and score between 2.0/8.0 and 4.0/8.0 indicates “mildly irritant” and score above 4.0/8.0 indicates “irritant”. Follow-up was scheduled after one week to confirm recovery for any reaction. The procedure of the patch test followed the principles outlined by Bureau of Indian standards (BIS) (IS 4011:2018; Methods of Test for safety evaluation of Cosmetics-3rd revision). Fifty six subjects with mean age 30.9 years (27 males and 29 females) participated in the study. The combined mean score (± standard deviation) were: 0.13 ± 0.33 (Brand A), 0.39 ± 0.49 (Brand B), 0.22 ± 0.41 (Brand C), 2.91 ± 0.79 (Positive control) and 0.02 ± 0.13 (Negative control). The mean score of Brand A (Sun Pharma product) was significantly lower than Brand B (p=0.001) and was comparable with Brand C (p=0.21). The combined mean erythema score (± standard deviation) were: 0.09 ± 0.29 (Brand A), 0.27 ± 0.5 (Brand B), 0.18 ± 0.39 (Brand C), 2.02 ± 0.49 (Positive control) and 0.0 ± 0.0 (Negative control). The mean erythema score of Brand A was significantly lower than Brand B (p=0.01) and was comparable with Brand C (p=0.16). Any reaction observed at 24hours after patch removal subsided in a week. All the three topical formulation of minoxidil 5% were non-irritant. Brand A of 5% minoxidil (Sun Pharma) was found to be least irritant than Brand B and Brand C based on the combined mean score and mean erythema score in the human patch test as per the BIS, IS 4011;2018.

Keywords: erythema, irritation, minoxidil, patch test

Procedia PDF Downloads 71
895 A Study of Student Satisfaction of the University TV Station

Authors: Prapoj Na Bangchang

Abstract:

This research aimed to study the satisfaction of university students on the Suan Sunandha Rajabhat University television station. The sample were 250 undergraduate students from Year 1 to Year 4. The tool used to collect data was a questionnaire. Statistics used in data analysis were percentage, mean and standard deviation. The results showed that student satisfaction on the University's television station location received high score, followed by the number of devices, and the content presented received the lowest score. Most students want the content of the programs to be improved especially entertainment content, followed by sports content.

Keywords: student satisfaction, university TV channel, media, broadcasting

Procedia PDF Downloads 346
894 Dentofacial-Targeted Bullying: A Review

Authors: Mai Ashraf Talaat

Abstract:

Bullying is an aggressive behavior and a serious issue that should be addressed by everyone and should be avoided at all costs. It is very common among adolescents and schoolchildren and the effects can be devastating and long-lasting. Students are most commonly bullied about physical appearance, race, gender, disability, ethnicity, religion, and sexual orientation. Appearance-targeted bullying is a form of bullying that targets an aspect of a person's appearance, which includes facial and dental features. Deviation from accepted dentofacial aesthetics leads to elevated incidences of bullying in schoolchildren. The aim of this review article is to assess the prevalence of bullying due to dentofacial characteristics and evaluate the importance of dentofacial appearance on perceived social attractiveness based on multiple studies.

Keywords: dentofacial features, orthodontics, malocclusion, adolescents, bullying

Procedia PDF Downloads 38
893 Modelling and Control of Electrohydraulic System Using Fuzzy Logic Algorithm

Authors: Hajara Abdulkarim Aliyu, Abdulbasid Ismail Isa

Abstract:

This research paper studies electrohydraulic system for its role in position and motion control system and develops as mathematical model describing the behaviour of the system. The research further proposes Fuzzy logic and conventional PID controllers in order to achieve both accurate positioning of the payload and overall improvement of the system performance. The simulation result shows Fuzzy logic controller has a superior tracking performance and high disturbance rejection efficiency for its shorter settling time, less overshoot, smaller values of integral of absolute and deviation errors over the conventional PID controller at all the testing conditions.

Keywords: electrohydraulic, fuzzy logic, modelling, NZ-PID

Procedia PDF Downloads 427
892 Cost Overrun Causes in Public Construction Projects in Saudi Arabia

Authors: Ibrahim Mahamid, A. Al-Ghonamy, M. Aichouni

Abstract:

This study is conducted to identify causes of cost deviations in public construction projects in Saudi Arabia from contractors’ perspective. 41 factors that might affect cost estimating accuracy were identified through literature review and discussion with some construction experts. The factors were tabulated in a questionnaire form and a field survey included 51 contractors from the Northern Province of Saudi Arabia was performed. The results show that the top five important causes are: wrong estimation method, long period between design and time of implementation, cost of labor, cost of machinary and absence of construction-cost data.

Keywords: cost deviation, public construction, cost estimating, Saudi Arabia, contractors

Procedia PDF Downloads 431
891 Numerical Study of a 6080HP Open Drip Proof (ODP) Motor

Authors: Feng-Hisang Lai

Abstract:

CFD(Computational Fluid Dynamics) is conducted to numerically study the flow and heat transfer features of a two-pole, 6,080HP, 60Hz, 3,150V open drip-proof (ODP) motor. The stator and rotor cores in this high voltage induction motor are segmented with the use of spacers for cooling purposes, which leads to difficulties in meshing when the entire system is to be simulated. The system is divided into 4 parts, meshed separately and then combined using interfaces. The deviation between the CFD and experimental results in temperature and flow rate is less than 10%. The internal flow is further examined and a final design is proposed to reduce the winding temperature by 10 degrees.

Keywords: CFD, open drip proof, induction motor, cooling

Procedia PDF Downloads 159
890 The Microwave and Far Infrared Spectra of Acetaldehyde-d1 in vt=2

Authors: A. Larrousi, M. Elkeurti, K. Amara, M. Zemouli, L. H. Coudert, I. R. Medvedev, F. C. De Lucia, Atsuko Maeda, R. W. C. McKellar, D. Appadoo

Abstract:

Experimental and theoretical investigations of the microwave and far infrared spectra of CH3COD are reported. Two hundred twelve lines were identified in the far infrared spectrum recorded using the Canadian synchrotron radiation light source. Two thousand one hundred and sixty-eight lines in vt=0,1 and 216 in vt=2 have been measured in the microwave spectrum obtained using the fast scan submillimeter spectroscopic technique. A global analysis of the new data and of already available microwave lines has been carried out and yielded values for rotation–torsion parameters. The unitless weighted standard deviation of the fit is 1.6. 46 parameters and 216 lines were identified.

Keywords: CH3COD, torsion, the microwave spectra, far infrared spectra high resolution

Procedia PDF Downloads 322
889 Evaluation of the Irritation Potential of Three Topical Formulations of Minoxidil 5% + Finasteride 0.1% Using Patch Test

Authors: Joshi Rajiv, Shah Priyank, Thavkar Amit, Rohira Poonam, Mehta Suyog

Abstract:

Topical formulation containing minoxidil and finasteride helps hair growth in the treatment of male androgenetic alopecia. The objective of this study is to compare the irritation potential of three conventional formulations of minoxidil 5% + finasteride 0.1% topical solution of in human patch test. The study was a single centre, double blind, non-randomized controlled study in 53 healthy adult Indian subjects. Occlusive patch test for 24 hours was performed with three formulations of minoxidil 5% + finasteride 0.1% topical solution. Products tested included aqueous based minoxidil 5% + finasteride 0.1% (AnasureTM-F, Sun Pharma, India – Brand A), lipid based minoxidil 5% + finasteride 0.1% (Brand B) and aqueous based minoxidil 5% + finasteride 0.1% (Brand C). Isotonic saline 0.9% and 1% w/w sodium lauryl sulphate were included as negative control and positive control respectively. Patches were applied and removed after 24 hours. The skin reaction was assessed and clinically scored 24 hours after the removal of the patches under constant artificial daylight source using the Draize scale (0-4 points scale for erythema/dryness//wrinkles and for oedema). Follow-up was scheduled after one week to confirm recovery for any reaction. A combined mean score up to 2.0/8.0 indicates a product is “non-irritant” and a score between 2.0/8.0 and 4.0/8.0 indicates “mildly irritant” and a score above 4.0/8.0 indicates “irritant”. The procedure of the patch test followed the principles outlined by the Bureau of Indian Standards (BIS) (IS 4011:2018; Methods of Test for safety evaluation of Cosmetics-3rd revision). Fifty three subjects with mean age 31.9 years (25 males and 28 females) participated in the study. The combined mean score ± standard deviation were: 0.06 ± 0.23 (Brand A), 0.81 ± 0.59 (Brand B), 0.38 ± 0.49 (Brand C), 2.92 ± 0.47 (positive control) and 0.0 ± 0.0 (Negative control). This means the score of Brand A (Sun Pharma product) was significantly lower than that of Brand B (p=0.001) and that of Brand C (p=0.001). The combined mean erythema score ± standard deviation were: 0.06 ± 0.23 (Brand A), 0.81 ± 0.59 (Brand B), 0.38 ± 0.49 (Brand C), 2.09 ± 0.4 (Positive control) and 0.0 ± 0.0 (Negative control). The mean erythema score of Brand A was significantly lower than Brand B (p=0.001) and that of Brand C (p=0.001). Any reaction observed at 24hours after patch removal subsided in a week. All the three topical formulations of minoxidil 5% + finasteride 0.1% were non-irritant. Brand A of minoxidil 5% + finasteride 0.1% (Sun Pharma) was found to be the least irritant than Brand B and Brand C based on the combined mean score and mean erythema score in the human patch test as per the BIS, IS 4011:2018

Keywords: erythema, finasteride, irritation, minoxidil, patch test

Procedia PDF Downloads 53
888 Evaluation of the Irritation Potential of Three Topical Formulations of Minoxidil 2% Using Patch Test

Authors: Sule Pallavi, Shah Priyank, Thavkar Amit, Rohira Poonam, Mehta Suyog

Abstract:

Introduction: Minoxidil has been used topically for a long time to assist hair growth in the management of male androgenetic alopecia. The aim of this study was a comparative assessment of the irritation potential of three commercial formulations of minoxidil 2% topical solution in a human patch test. Methodology: The study was a non-randomized, double-blind, controlled, single-center study of 56 healthy adult Indian subjects. A 24-hour occlusive patch test was conducted with three formulations of minoxidil 2% topical solution. Products tested were aqueous-based minoxidil 2% (AnasureTM 2%, Sun Pharma, India – Brand A), alcohol-based minoxidil 2% (Brand B) and aqueous-based minoxidil 2% (Brand C). Isotonic saline 0.9% and 1% w/w sodium lauryl sulphate as a negative and positive control, respectively, were included. Patches were applied on the back, followed by removal after 24 hours. The Draize scale (0-4 points scale for erythema/dryness/wrinkles and for oedema) was used to evaluate and clinically score the skin reaction under constant artificial daylight 24 hours after the removal of the patches. The patch test was based on the principles outlined by Bureau of Indian Standards (BIS) (IS 4011:2018; Methods of Test for safety evaluation of Cosmetics-3rd revision). A mean combined score up to 2.0/8.0 indicates that a product is “non-irritant,” and a score between 2.0/8.0 and 4.0/8.0 indicates “mildly irritant” and a score above 4.0/8.0 indicates “irritant”. In case of any skin reaction that was observed, a follow-up was planned after one week to confirm recovery. Results: The 56 subjects who participated in the study had a mean age of 28.7 years (28 males and 28 females). The combined mean score ± standard deviation was: 0.09 ± 0.29 (Brand A), 0.29± 0.53 (Brand B), 0.30 ± 0.46 (Brand C), 3.25 ± 0.77 (positive control) and 0.02 ± 0.13 (negative control). This mean score of Brand A (Sun Pharma) was significantly lower than that of Brand B (p=0.016) and that of Brand C (p=0.004). The mean erythema score ± standard deviation was: 0.09 ± 0.29 (Brand A), 0.27 ± 0.49 (Brand B), 0.30 ± 0.46 (Brand C), 2.5 ± 0.66 (positive control) and 0.02 ± 0.13 (negative control). The mean erythema score of Brand A (Sun Pharma) was significantly lower than that of Brand B (p=0.019) and that of Brand C (p=0.004). Reactions that were observed 24 hours after patch removal subsided in a week’s time. Conclusion: Based on the human patch test as per the BIS, IS 4011:2018, all the three topical formulations of minoxidil 2% were found to be non-irritant. Brand A of 2% minoxidil (Sun Pharma) was found to be the least irritant than Brand B and Brand C based on the combined mean score and mean erythema score.

Keywords: erythema, irritation, minoxidil, patch test

Procedia PDF Downloads 60
887 Optimization of Black-Litterman Model for Portfolio Assets Allocation

Authors: A. Hidalgo, A. Desportes, E. Bonin, A. Kadaoui, T. Bouaricha

Abstract:

Present paper is concerned with portfolio management with Black-Litterman (B-L) model. Considered stocks are exclusively limited to large companies stocks on US market. Results obtained by application of the model are presented. From analysis of collected Dow Jones stock data, remarkable explicit analytical expression of optimal B-L parameter τ, which scales dispersion of normal distribution of assets mean return, is proposed in terms of standard deviation of covariance matrix. Implementation has been developed in Matlab environment to split optimization in Markovitz sense from specific elements related to B-L representation.

Keywords: Black-Litterman, Markowitz, market data, portfolio manager opinion

Procedia PDF Downloads 232