Search results for: Win Thandar Soe
3 Energy Management System and Interactive Functions of Smart Plug for Smart Home
Authors: Win Thandar Soe, Innocent Mpawenimana, Mathieu Di Fazio, Cécile Belleudy, Aung Ze Ya
Abstract:
Intelligent electronic equipment and automation network is the brain of high-tech energy management systems in critical role of smart homes dominance. Smart home is a technology integration for greater comfort, autonomy, reduced cost, and energy saving as well. These services can be provided to home owners for managing their home appliances locally or remotely and consequently allow them to automate intelligently and responsibly their consumption by individual or collective control systems. In this study, three smart plugs are described and one of them tested on typical household appliances. This article proposes to collect the data from the wireless technology and to extract some smart data for energy management system. This smart data is to quantify for three kinds of load: intermittent load, phantom load and continuous load. Phantom load is a waste power that is one of unnoticed power of each appliance while connected or disconnected to the main. Intermittent load and continuous load take in to consideration the power and using time of home appliances. By analysing the classification of loads, this smart data will be provided to reduce the communication of wireless sensor network for energy management system.Keywords: energy management, load profile, smart plug, wireless sensor network
Procedia PDF Downloads 2712 Wiedemann-Franz Law Violation Domain for Graphene and Nonrelativistic Systems
Authors: Thandar Zaw Win, Cho Win Aung, Gaurav Khandal, Sabyasachi Ghosh
Abstract:
Systematic and comparative research on Lorenz ratios for graphene and nonrelativistic systems has been studied to identify their Wiedemann-Franz law violation domain. Fermi energy and temperature are the main governing parameters for deciding the values of the Lorenz ratio, which is basically thermal conductivity divided by electrical conductivity times temperature times Lorenz number. Metals as three-dimensional nonrelativistic electron gas are located at higher Fermi-energy by temperature domain, where Lorenz ratio remains one. Hence, they obey the Wiedemann-Franz law. By creating higher doping in a two-dimensional graphene system, one can again reach a higher Fermi-energy by temperature domain and get a constant Lorenz ratio. For both graphene and nonrelativistic systems, the Lorenz ratio goes below one if we go lower Fermi-energy by temperature domain, which is possible for the graphene system by decreasing the doping concentration. Experimentally observed greater than one Lorenz ratio in this lower Fermi-energy by temperature domain or Dirac Fluid domain indicates that nonfluid expressions of Lorenz ratio should be replaced by fluidtype expressions. We have noticed a divergent trend of Lorenz ratio in the Dirac Fluid domain using its fluid-type expression, and it matches the trend of experimental data.Keywords: graphene, Lorentz ratio, specific heat, Wiedeann-Franz law
Procedia PDF Downloads 311 Ballistic Performance of Magnesia Panels and Modular Wall Systems
Authors: Khin Thandar Soe, Mark Stephen Pulham
Abstract:
Ballistic building materials play a crucial role in ensuring the safety of the occupants within protective structures. Traditional options like Ordinary Portland Cement (OPC)-based walls, including reinforced concrete walls, precast concrete walls, masonry walls, and concrete blocks, are frequently employed for ballistic protection, but they have several drawbacks such as being thick, heavy, costly, and challenging to construct. On the other hand, glass and composite materials offer lightweight and easier construction alternatives, but they come with a high price tag. There has been no reported test data on magnesium-based ballistic wall panels or modular wall systems so far. This paper presents groundbreaking small arms test data related to the development of the world’s first magnesia cement ballistic wall panels and modular wall system. Non-hydraulic magnesia cement exhibits several superior properties, such as lighter weight, flexibility, acoustics, and fire performance, compared to the traditional Portland Cement. However, magnesia cement is hydrophilic and may degrade in prolonged contact with water. In this research, modified magnesia cement for water resistant and durability from UBIQ Technology is applied. The specimens are made of a modified magnesia cement formula and prepared in the Laboratory of UBIQ Technology Pty Ltd. The specimens vary in thickness, and the tests cover various small arms threats in compliance with standards AS/NZS2343 and UL752 and are performed up to the maximum threat level of Classification R2 (NATO) and UL-Level 8(NATO) by the Accredited Test Centre, BMT (Ballistic and Mechanical Testing, VIC, Australia). In addition, the results of the test conducted on the specimens subjected to the small 12mm diameter steel ball projectile impact generated by a gas gun are also presented and discussed in this paper. Gas gun tests were performed in UNSW@ADFA, Canberra, Australia. The tested results of the magnesia panels and wall systems are compared with one of concrete and other wall panels documented in the literature. The conclusion drawn is that magnesia panels and wall systems exhibit several advantages over traditional OPC-based wall systems, and they include being lighter, thinner, and easier to construct, all while providing equivalent protection against threats. This makes magnesia cement-based materials a compelling choice of application where efficiency and performance are critical to create a protective environment.Keywords: ballistics, small arms, gas gun, projectile, impact, wall panels, modular, magnesia cement
Procedia PDF Downloads 75