Search results for: V. Golubeva
4 Determination of Gold in Microelectronics Waste Pieces
Authors: S. I. Usenko, V. N. Golubeva, I. A. Konopkina, I. V. Astakhova, O. V. Vakhnina, A. A. Korableva, A. A. Kalinina, K. B. Zhogova
Abstract:
Gold can be determined in natural objects and manufactured articles of different origin. The up-to-date status of research and problems of high gold level determination in alloys and manufactured articles are described in detail in the literature. No less important is the task of this metal determination in minerals, process products and waste pieces. The latters, as objects of gold content chemical analysis, are most hard-to-study for two reasons: Because of high requirements to accuracy of analysis results and because of difference in chemical and phase composition. As a rule, such objects are characterized by compound, variable and very often unknown matrix composition that leads to unpredictable and uncontrolled effect on accuracy and other analytical characteristics of analysis technique. In this paper, the methods for the determination of gold are described, using flame atomic-absorption spectrophotometry and gravimetric analysis technique. The techniques are aimed at gold determination in a solution for gold etching (KJ+J2), in the technological mixture formed after cleaning stainless steel members of vacuum-deposit installation with concentrated nitric and hydrochloric acids as well as in gold-containing powder resulted from liquid wastes reprocessing. Optimal conditions for sample preparation and analysis of liquid and solid waste specimens of compound and variable matrix composition were chosen. The boundaries of relative resultant error were determined for the methods within the range of gold mass concentration from 0.1 to 30g/dm3 in the specimens of liquid wastes and mass fractions from 3 to 80% in the specimens of solid wastes.Keywords: microelectronics waste pieces, gold, sample preparation, atomic-absorption spectrophotometry, gravimetric analysis technique
Procedia PDF Downloads 2043 A Study of Surface of Titanium Targets for Neutron Generators
Authors: Alexey Yu. Postnikov, Nikolay T. Kazakovskiy, Valery V. Mokrushin, Irina A. Tsareva, Andrey A. Potekhin, Valentina N. Golubeva, Yuliya V. Potekhina, Maxim V. Tsarev
Abstract:
The development of tritium and deuterium targets for neutron tubes and generators is a part of the activities in All-Russia Research Institute of Experimental Physics (RFNC-VNIIEF). These items contain a metal substrate (for example, copper) with a titanium film with a few microns thickness deposited on it. Then these metal films are saturated with tritium, deuterium or their mixtures. The significant problem in neutron tubes and neutron generators is the characterization of substrate surface before a deposition of titanium film on it, and analysis of the deposited titanium film’s surface before hydrogenation and after a saturation of the film with hydrogen isotopes. The performance effectiveness of neutron tube and generator also depends on upon the quality parameters of the surface of the initial substrate, deposited metal film and hydrogenated target. The objective of our work is to study the target prototype samples, that have differ by various approaches to the preliminary chemical processing of a copper substrate, and to analyze the integrity of titanium film after its saturation with deuterium. The research results of copper substrate and the surface of deposited titanium film with the use of electron microscopy, X-ray spectral microanalysis and laser-spark methods of analyses are presented. The causes of surface defects appearance have been identified. The distribution of deuterium and some impurities (oxygen and nitrogen) along the surface and across the height of the hydrogenated film in the target has been established. This allows us to evaluate the composition homogeneity of the samples and consequently to estimate the quality of hydrogenated samples. As the result of this work the propositions on the advancement of production technology and characterization of target’s surface have been presented.Keywords: tritium and deuterium targets, titanium film, laser-spark methods, electron microscopy
Procedia PDF Downloads 4422 A Serum- And Feeder-Free Culture System for the Robust Generation of Human Stem Cell-Derived CD19+ B Cells and Antibody-Secreting Cells
Authors: Kirsten Wilson, Patrick M. Brauer, Sandra Babic, Diana Golubeva, Jessica Van Eyk, Tinya Wang, Avanti Karkhanis, Tim A. Le Fevre, Andy I. Kokaji, Allen C. Eaves, Sharon A. Louis, , Nooshin Tabatabaei-Zavareh
Abstract:
Long-lived plasma cells are rare, non-proliferative B cells generated from antibody-secreting cells (ASCs) following an immune response to protect the host against pathogen re-exposure. Despite their therapeutic potential, the lack of in vitro protocols in the field makes it challenging to use B cells as a cellular therapeutic tool. As a result, there is a need to establish robust and reproducible methods for the generation of B cells. To address this, we have developed a culture system for generating B cells from hematopoietic stem and/or progenitor cells (HSPCs) derived from human umbilical cord blood (CB) or pluripotent stem cells (PSCs). HSPCs isolated from CB were cultured using the StemSpan™ B Cell Generation Kit and produced CD19+ B cells at a frequency of 23.2 ± 1.5% and 59.6 ± 2.3%, with a yield of 91 ± 11 and 196 ± 37 CD19+ cells per input CD34+ cell on culture days 28 and 35, respectively (n = 50 - 59). CD19+IgM+ cells were detected at a frequency of 31.2 ± 2.6% and were produced at a yield of 113 ± 26 cells per input CD34+ cell on culture day 35 (n = 50 - 59). The B cell receptor loci of CB-derived B cells were sequenced to confirm V(D)J gene rearrangement. ELISpot analysis revealed that ASCs were generated at a frequency of 570 ± 57 per 10,000 day 35 cells, with an average IgM+ ASC yield of 16 ± 2 cells per input CD34+ cell (n = 33 - 42). PSC-derived HSPCs were generated using the STEMdiff™ Hematopoietic - EB reagents and differentiated to CD10+CD19+ B cells with a frequency of 4 ± 0.8% after 28 days of culture (n = 37, 1 embryonic and 3 induced pluripotent stem cell lines tested). Subsequent culture of PSC-derived HSPCs increased CD19+ frequency and generated ASCs from 1 - 2 iPSC lines. This method is the first report of a serum- and feeder-free system for the generation of B cells from CB and PSCs, enabling further B lineage-specific research for potential future clinical applications.Keywords: stem cells, B cells, immunology, hematopoiesis, PSC, differentiation
Procedia PDF Downloads 571 Determination of Bromides, Chlorides and Fluorides in Case of Their Joint Presence in Ion-Conducting Electrolyte
Authors: V. Golubeva, O. Vakhnina, I. Konopkina, N. Gerasimova, N. Taturina, K. Zhogova
Abstract:
To improve chemical current sources, the ion-conducting electrolytes based on Li halides (LiCl-KCl, LiCl-LiBr-KBr, LiCl-LiBr-LiF) are developed. It is necessary to have chemical analytical methods for determination of halides to control the electrolytes technology. The methods of classical analytical chemistry are of interest, as they are characterized by high accuracy. Using these methods is a difficult task because halides have similar chemical properties. The objective of this work is to develop a titrimetric method for determining the content of bromides, chlorides, and fluorides in their joint presence in an ion-conducting electrolyte. In accordance with the developed method of analysis to determine fluorides, electrolyte sample is dissolved in diluted HCl acid; fluorides are titrated by La(NO₃)₃ solution with potentiometric indication of equivalence point, fluoride ion-selective electrode is used as sensor. Chlorides and bromides do not form a hardly soluble compound with La and do not interfere in result of analysis. To determine the bromides, the sample is dissolved in a diluted H₂SO₄ acid. The bromides are oxidized with a solution of KIO₃ to Br₂, which is removed from the reaction zone by boiling. Excess of KIO₃ is titrated by iodometric method. The content of bromides is calculated from the amount of KIO₃ spent on Br₂ oxidation. Chlorides and fluorides are not oxidized by KIO₃ and do not interfere in result of analysis. To determine the chlorides, the sample is dissolved in diluted HNO₃ acid and the total content of chlorides and bromides is determined by method of visual mercurometric titration with diphenylcarbazone indicator. Fluorides do not form a hardly soluble compound with mercury and do not interfere with determination. The content of chlorides is calculated taking into account the content of bromides in the sample of electrolyte. The validation of the developed analytical method was evaluated by analyzing internal reference material with known chlorides, bromides and fluorides content. The analytical method allows to determine chlorides, bromides and fluorides in case of their joint presence in ion-conducting electrolyte within the range and with relative total error (δ): for bromides from 60.0 to 65.0 %, δ = ± 2.1 %; for chlorides from 8.0 to 15.0 %, δ = ± 3.6 %; for fluorides from 5.0 to 8.0%, ± 1.5% . The analytical method allows to analyze electrolytes and mixtures that contain chlorides, bromides, fluorides of alkali metals and their mixtures (K, Na, Li).Keywords: bromides, chlorides, fluorides, ion-conducting electrolyte
Procedia PDF Downloads 127