Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3
Search results for: Sharmili Routray
3 Effect of Fiber Orientation on the Mechanical Properties of Fabricated Plate Using Basalt Fiber
Authors: Sharmili Routray, Kishor Chandra Biswal
Abstract:
The use of corrosion resistant fiber reinforced polymer (FRP) reinforcement is beneficial in structures particularly those exposed to deicing salts, and/or located in highly corrosive environment. Generally Glass, Carbon and Aramid fibers are used for the strengthening purpose of the structures. Due to the necessities of low weight and high strength materials, it is required to find out the suitable substitute with low cost. Recent developments in fiber production technology allow the strengthening of structures using Basalt fiber which is made from basalt rock. Basalt fiber has good range of thermal performance, high tensile strength, resistance to acids, good electro‐magnetic properties, inert nature, resistance to corrosion, radiation and UV light, vibration and impact loading. This investigation focuses on the effect of fibre content and fiber orientation of basalt fibre on mechanical properties of the fabricated composites. Specimen prepared with unidirectional Basalt fabric as reinforcing materials and epoxy resin as a matrix in polymer composite. In this investigation different fiber orientation are taken and the fabrication is done by hand lay-up process. The variation of the properties with the increasing number of plies of fiber in the composites is also studied. Specimens are subjected to tensile strength test and the failure of the composite is examined with the help of INSTRON universal testing Machine (SATEC) of 600 kN capacities. The average tensile strength and modulus of elasticity of BFRP plates are determined from the test Program.Keywords: BFRP, fabrication, Fiber Reinforced Polymer (FRP), strengthening
Procedia PDF Downloads 2922 Frequency Selective Filters for Estimating the Equivalent Circuit Parameters of Li-Ion Battery
Authors: Arpita Mondal, Aurobinda Routray, Sreeraj Puravankara, Rajashree Biswas
Abstract:
The most difficult part of designing a battery management system (BMS) is battery modeling. A good battery model can capture the dynamics which helps in energy management, by accurate model-based state estimation algorithms. So far the most suitable and fruitful model is the equivalent circuit model (ECM). However, in real-time applications, the model parameters are time-varying, changes with current, temperature, state of charge (SOC), and aging of the battery and this make a great impact on the performance of the model. Therefore, to increase the equivalent circuit model performance, the parameter estimation has been carried out in the frequency domain. The battery is a very complex system, which is associated with various chemical reactions and heat generation. Therefore, it’s very difficult to select the optimal model structure. As we know, if the model order is increased, the model accuracy will be improved automatically. However, the higher order model will face the tendency of over-parameterization and unfavorable prediction capability, while the model complexity will increase enormously. In the time domain, it becomes difficult to solve higher order differential equations as the model order increases. This problem can be resolved by frequency domain analysis, where the overall computational problems due to ill-conditioning reduce. In the frequency domain, several dominating frequencies can be found in the input as well as output data. The selective frequency domain estimation has been carried out, first by estimating the frequencies of the input and output by subspace decomposition, then by choosing the specific bands from the most dominating to the least, while carrying out the least-square, recursive least square and Kalman Filter based parameter estimation. In this paper, a second order battery model consisting of three resistors, two capacitors, and one SOC controlled voltage source has been chosen. For model identification and validation hybrid pulse power characterization (HPPC) tests have been carried out on a 2.6 Ah LiFePO₄ battery.Keywords: equivalent circuit model, frequency estimation, parameter estimation, subspace decomposition
Procedia PDF Downloads 1481 Preparedness Level of Disaster Management Institutions in Context of Floods in Delhi
Authors: Aditi Madan, Jayant Kumar Routray
Abstract:
Purpose: Over the years flood related risks have compounded due to increasing vulnerability caused by rapid urbanisation and growing population. This increase is an indication of the need for enhancing the preparedness of institutions to respond to floods. The study describes disaster management structure and its linkages with institutions involved in managing disasters. It addresses issues and challenges associated with readiness of disaster management institutions to respond to floods. It suggests policy options for enhancing the current state of readiness of institutions to respond by considering factors like institutional, manpower, financial, technical, leadership & networking, training and awareness programs, monitoring and evaluation. Methodology: The study is based on qualitative data with statements and outputs from primary and secondary sources to understand the institutional framework for disaster management in India. Primary data included field visits, interviews with officials from institutions managing disasters and the affected community to identify the challenges faced in engaging national, state, district and local level institutions in managing disasters. For focus group discussions, meetings were held with district project officers and coordinators, local officials, community based organisation, civil defence volunteers and community heads. These discussions were held to identify the challenges associated with preparedness to respond of institutions to floods. Findings: Results show that disasters are handled by district authority and the role of local institutions is limited to a reactive role during disaster. Data also indicates that although the existing institutional setup is well coordinated at the district level but needs improvement at the local level. Wide variations exist in awareness and perception among the officials engaged in managing disasters. Additionally, their roles and responsibilities need to be clearly defined with adequate budget and dedicated permanent staff for managing disasters. Institutions need to utilise the existing manpower through proper delegation of work. Originality: The study suggests that disaster risk reduction needs to focus more towards inclusivity of the local urban bodies. Wide variations exist in awareness and perception among the officials engaged in managing disasters. In order to ensure community participation, it is important to address their social and economic problems since such issues can overshadow attempts made for reducing risks. Thus, this paper suggests development of direct linkages among institutions and community for enhancing preparedness to respond to floods.Keywords: preparedness, response, disaster, flood, community, institution
Procedia PDF Downloads 234