Search results for: P. K. Nema
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 8

Search results for: P. K. Nema

8 Evaluation of SDS (Software Defined Storage) Controller (CorpHD) for Various Storage Demands

Authors: Shreya Bokare, Sanjay Pawar, Shika Nema

Abstract:

Growth in cloud applications is generating the tremendous amount of data, building load on traditional storage management systems. Software Defined Storage (SDS) is a new storage management concept becoming popular to handle this large amount of data. CoprHD is one of the open source SDS controller, available for experimentation and development in the storage industry. In this paper, the storage management techniques provided by CoprHD to manage heterogeneous storage platforms are experimented and analyzed. Various storage management parameters such as time to provision, storage capacity measurement, and heterogeneity are experimentally evaluated along with the theoretical expression to prove the completeness of CoprHD controller for storage management.

Keywords: software defined storage, SDS, CoprHD, open source, SMI-S simulator, clarion, Symmetrix

Procedia PDF Downloads 268
7 Phantom and Clinical Evaluation of Block Sequential Regularized Expectation Maximization Reconstruction Algorithm in Ga-PSMA PET/CT Studies Using Various Relative Difference Penalties and Acquisition Durations

Authors: Fatemeh Sadeghi, Peyman Sheikhzadeh

Abstract:

Introduction: Block Sequential Regularized Expectation Maximization (BSREM) reconstruction algorithm was recently developed to suppress excessive noise by applying a relative difference penalty. The aim of this study was to investigate the effect of various strengths of noise penalization factor in the BSREM algorithm under different acquisition duration and lesion sizes in order to determine an optimum penalty factor by considering both quantitative and qualitative image evaluation parameters in clinical uses. Materials and Methods: The NEMA IQ phantom and 15 clinical whole-body patients with prostate cancer were evaluated. Phantom and patients were injected withGallium-68 Prostate-Specific Membrane Antigen(68 Ga-PSMA)and scanned on a non-time-of-flight Discovery IQ Positron Emission Tomography/Computed Tomography(PET/CT) scanner with BGO crystals. The data were reconstructed using BSREM with a β-value of 100-500 at an interval of 100. These reconstructions were compared to OSEM as a widely used reconstruction algorithm. Following the standard NEMA measurement procedure, background variability (BV), recovery coefficient (RC), contrast recovery (CR) and residual lung error (LE) from phantom data and signal-to-noise ratio (SNR), signal-to-background ratio (SBR) and tumor SUV from clinical data were measured. Qualitative features of clinical images visually were ranked by one nuclear medicine expert. Results: The β-value acts as a noise suppression factor, so BSREM showed a decreasing image noise with an increasing β-value. BSREM, with a β-value of 400 at a decreased acquisition duration (2 min/ bp), made an approximately equal noise level with OSEM at an increased acquisition duration (5 min/ bp). For the β-value of 400 at 2 min/bp duration, SNR increased by 43.7%, and LE decreased by 62%, compared with OSEM at a 5 min/bp duration. In both phantom and clinical data, an increase in the β-value is translated into a decrease in SUV. The lowest level of SUV and noise were reached with the highest β-value (β=500), resulting in the highest SNR and lowest SBR due to the greater noise reduction than SUV reduction at the highest β-value. In compression of BSREM with different β-values, the relative difference in the quantitative parameters was generally larger for smaller lesions. As the β-value decreased from 500 to 100, the increase in CR was 160.2% for the smallest sphere (10mm) and 12.6% for the largest sphere (37mm), and the trend was similar for SNR (-58.4% and -20.5%, respectively). BSREM visually was ranked more than OSEM in all Qualitative features. Conclusions: The BSREM algorithm using more iteration numbers leads to more quantitative accuracy without excessive noise, which translates into higher overall image quality and lesion detectability. This improvement can be used to shorter acquisition time.

Keywords: BSREM reconstruction, PET/CT imaging, noise penalization, quantification accuracy

Procedia PDF Downloads 64
6 Electroencephalogram Signals Controlling a Parallax Boe-Bot Robot

Authors: Nema M. Salem, Hanan A. Altukhaifi, Amal Mukhtar, Reemaz K. Hetaimish

Abstract:

Recently, BCI field of research has gained a lot of interest. Apart from motor neuroprosthetics, many studies showed the possibility of controlling a virtual environment of a videogame using the acquired electroencephalogram signals (EEG) from the gamer. In addition, another study had successfully moved a farm tractor using the human’s EEG signals. This article utilizes the use of EEG signals, as a source of technology, in controlling a Parallax Boe-Bot robot. The commercial Emotive Epoc headset has been used in acquiring the EEG signals from rested subjects. Because the human's visual cortex can successfully differentiate between different colors, the red and green colors are used as visual stimuli for generating EEG signals using the Epoc. Arduino and Labview are used to translate the virtually pressed keys into instructions controlling the motion and rotation of the robot. Optimistic results have been achieved except for minor delay and accuracy in the robot’s response.

Keywords: BCI, Emotiv Epoc headset, EEG, Labview, Arduino applications, robot

Procedia PDF Downloads 486
5 A Method to Determine Cutting Force Coefficients in Turning Using Mechanistic Approach

Authors: T. C. Bera, A. Bansal, D. Nema

Abstract:

During performing turning operation, cutting force plays a significant role in metal cutting process affecting tool-work piece deflection, vibration and eventually part quality. The present research work aims to develop a mechanistic cutting force model and to study the mechanistic constants used in the force model in case of turning operation. The proposed model can be used for the reliable and accurate estimation of the cutting forces establishing relationship of various force components (cutting force and feed force) with uncut chip thickness. The accurate estimation of cutting force is required to improve thin-walled part accuracy by controlling the tool-work piece deflection induced surface errors and tool-work piece vibration.

Keywords: turning, cutting forces, cutting constants, uncut chip thickness

Procedia PDF Downloads 484
4 Plasma Gasification as a Sustainable Way for Energy Recovery from Scrap Tyre

Authors: Gloria James, S. K. Nema, T. S. Anantha Singh, P. Vadivel Murugan

Abstract:

The usage of tyre has increased enormously in day to day life. The used tyre and rubber products pose major threat to the environment. Conventional thermal techniques such as low temperature pyrolysis and incineration produce high molecular organic compounds (condensed and collected as aromatic oil) and carbon soot particles. Plasma gasification technique can dispose tyre waste and generate combustible gases and avoid the formation of high molecular aromatic compounds. These gases generated in plasma gasification process can be used to generate electricity or as fuel wherever required. Although many experiments have been done on plasma pyrolysis of tyres, very little work has been done on plasma gasification of tyres. In this work plasma gasification of waste tyres have been conducted in a fixed bed reactor having graphite electrodes and direct current (DC) arc plasma system. The output of this work has been compared with the previous work done on plasma pyrolysis of tyres by different authors. The aim of this work is to compare different process based on gas generation, efficiency of the process and explore the most effective option for energy recovery from waste tyres.

Keywords: plasma, gasification, syngas, tyre waste

Procedia PDF Downloads 150
3 Development of Cost-Effective Protocol for Preparation of Dehydrated Paneer (Indian Cottage Cheese) Using Freeze Drying

Authors: Sadhana Sharma, P. K. Nema, Siddhartha Singha

Abstract:

Paneer or Indian cottage cheese is an acid and heat coagulated milk product, highly perishable because of high moisture (58-60 %). Typically paneer is marble to light creamy white in appearance. A good paneer should have cohesive body with slight sponginess or springiness. The texture must be smooth and velvety with close-knit compactness. It should have pleasing mild acidic, slightly sweet and nutty flavour. Consumers today demand simple to prepare, convenient, healthy and natural foods. Dehydrated paneer finds numerous ways to be used. It can be used in curry preparation similar to paneer-in-curry, a delicacy in Indian cuisine. It may be added to granola/ trail mix yielding a high energy snack. If grounded to a powder, it may be used as a cheesy spice mix or used as popcorn seasoning. Dried paneer powder may be added to pizza dough or to a white sauce to turn it into a paneer sauce. Drying of such food hydrogels by conventional methods is associated with several undesirable characteristics including case hardening, longer drying time, poor rehydration ability and fat loss during drying. The present study focuses on developing cost-effective protocol for freeze-drying of paneer. The dehydrated product would be shelf-stable and can be rehydrated to its original state having flavor and texture comparable to the fresh form. Moreover, the final product after rehydration would be more fresh and softer than its frozen counterparts. The developed product would be shelf-stable at room temperature without any addition of preservatives.

Keywords: color, freeze-drying, paneer, texture

Procedia PDF Downloads 129
2 Platelet Volume Indices: Emerging Markers of Diabetic Thrombocytopathy

Authors: Mitakshara Sharma, S. K. Nema

Abstract:

Diabetes mellitus (DM) is metabolic disorder prevalent in pandemic proportions, incurring significant morbidity and mortality due to associated vascular angiopathies. Platelet related thrombogenesis plays key role in pathogenesis of these complications. Most patients with type II DM suffer from preventable vascular complications and early diagnosis can help manage these successfully. These complications are attributed to platelet activation which can be recognised by the increase in Platelet Volume Indices(PVI) viz. Mean Platelet Volume(MPV) and Platelet Distribution Width(PDW). This study was undertaken with the aim of finding a relationship between PVI and vascular complications of Diabetes mellitus, their importance as a causal factor in these complications and use as markers for early detection of impending vascular complications in patients with poor glycaemic status. This is a cross-sectional study conducted for 2 years with total 930 subjects. The subjects were segregated in 03 groups on basis of glycosylated haemoglobin (HbA1C) as: - (a) Diabetic, (b) Non-Diabetic and (c) Subjects with Impaired fasting glucose(IFG) with 300 individuals in IFG and non-diabetic group & 330 individuals in diabetic group. The diabetic group was further divided into two groups: - (a) Diabetic subjects with diabetes related vascular complications (b) Diabetic subjects without diabetes related vascular complications. Samples for HbA1C and platelet indices were collected using Ethylene diamine tetracetic acid(EDTA) as anticoagulant and processed on SYSMEX-XS-800i autoanalyser. The study revealed stepwise increase in PVI from non-diabetics to IFG to diabetics. MPV and PDW of diabetics, IFG and non diabetics were 17.60 ± 2.04, 11.76 ± 0.73, 9.93 ± 0.64 and 19.17 ± 1.48, 15.49 ± 0.67, 10.59 ± 0.67 respectively with a significant p value 0.00 and a significant positive correlation (MPV-HbA1c r = 0.951; PDW-HbA1c r = 0.875). However, significant negative correlation was found between glycaemic levels and total platelet count (PC- HbA1c r =-0.164). MPV & PDW of subjects with and without diabetes related complications were (15.14 ± 1.04) fl & (17.51±0.39) fl and (18.96 ± 0.83) fl & (20.09 ± 0.98) fl respectively with a significant p value 0.00.The current study demonstrates raised platelet indices & reduced platelet counts in association with rising glycaemic levels and diabetes related vascular complications across various study groups & showed that platelet morphology is altered with increasing glycaemic levels. These changes can be known by measurements of PVI which are important, simple, cost effective, effortless tool & indicators of impending vascular complications in patients with deranged glycaemic control. PVI should be researched and explored further as surrogate markers to develop a clinical tool for early recognition of vascular changes related to diabetes and thereby help prevent them. They can prove to be more useful in developing countries with limited resources. This study is multi-parameter, comprehensive with adequately powered study design and represents pioneering effort in India on account of the fact that both Platelet indices (MPV & PDW) along with platelet count have been evaluated together for the first time in Diabetics, non diabetics, patients with IFG and also in the diabetic patients with and without diabetes related vascular complications.

Keywords: diabetes, HbA1C, IFG, MPV, PDW, PVI

Procedia PDF Downloads 207
1 Role of Platelet Volume Indices in Diabetes Related Vascular Angiopathies

Authors: Mitakshara Sharma, S. K. Nema, Sanjeev Narang

Abstract:

Diabetes mellitus (DM) is a group of metabolic disorders characterized by metabolic abnormalities, chronic hyperglycaemia and long term macrovascular & microvascular complications. Vascular complications are due to platelet hyperactivity and dysfunction, increased inflammation, altered coagulation and endothelial dysfunction. Large proportion of patients with Type II DM suffers from preventable vascular angiopathies, and there is need to develop risk factor modifications and interventions to reduce impact of complications. These complications are attributed to platelet activation, recognised by increase in Platelet Volume Indices (PVI) including Mean Platelet Volume (MPV) and Platelet Distribution Width (PDW). The current study is prospective analytical study conducted over 2 years. Out of 1100 individuals, 930 individuals fulfilled inclusion criteria and were segregated into three groups on basis of glycosylated haemoglobin (HbA1C): - (a) Diabetic, (b) Non-Diabetic and (c) Subjects with Impaired fasting glucose (IFG) with 300 individuals in IFG and non-diabetic groups & 330 individuals in diabetic group. Further, diabetic group was divided into two groups on the basis of presence or absence of known diabetes related vascular complications. Samples for HbA1c and PVI were collected using Ethylene diamine tetraacetic acid (EDTA) as anticoagulant and processed on SYSMEX-X-800i autoanalyser. The study revealed gradual increase in PVI from non-diabetics to IFG to diabetics. PVI were markedly increased in diabetic patients. MPV and PDW of diabetics, IFG and non diabetics were (17.60 ± 2.04)fl, (11.76 ± 0.73)fl, (9.93 ± 0.64)fl and (19.17 ± 1.48)fl, (15.49 ± 0.67)fl, (10.59 ± 0.67)fl respectively with a significant p value 0.00 and a significant positive correlation (MPV-HbA1c r = 0.951; PDW-HbA1c r = 0.875). MPV & PDW of subjects with diabetes related complications were higher as compared to those without them and were (17.51±0.39)fl & (15.14 ± 1.04)fl and (20.09 ± 0.98) fl & (18.96 ± 0.83)fl respectively with a significant p value 0.00. There was a significant positive correlation between PVI and duration of diabetes across the groups (MPV-HbA1c r = 0.951; PDW-HbA1c r = 0.875). However, a significant negative correlation was found between glycaemic levels and total platelet count (PC- HbA1c r =-0.164). This is multi-parameter and comprehensive study with an adequately powered study design. It can be concluded from our study that PVI are extremely useful and important indicators of impending vascular complications in all patients with deranged glycaemic control. Introduction of automated cell counters has facilitated the availability of PVI as routine parameters. PVI is a useful means for identifying larger & active platelets which play important role in development of micro and macro angiopathic complications of diabetes leading to mortality and morbidity. PVI can be used as cost effective markers to predict and prevent impending vascular events in patients with Diabetes mellitus especially in developing countries like India. PVI, if incorporated into protocols for management of diabetes, could revolutionize care and curtail the ever increasing cost of patient management.

Keywords: diabetes, IFG, HbA1C, MPV, PDW, PVI

Procedia PDF Downloads 224