Search results for: Najet Rebei
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3

Search results for: Najet Rebei

3 Open Circuit MPPT Control Implemented for PV Water Pumping System

Authors: Rabiaa Gammoudi, Najet Rebei, Othman Hasnaoui

Abstract:

Photovoltaic systems use different techniques for tracking the Maximum Power Point (MPPT) to provide the highest possible power to the load regardless of the climatic conditions variation. In this paper, the proposed method is the Open Circuit (OC) method with sudden and random variations of insolation. The simulation results of the water pumping system controlled by OC method are validated by an experimental experience in real-time using a test bench composed by a centrifugal pump powered by a PVG via a boost chopper for the adaptation between the source and the load. The output of the DC/DC converter supplies the motor pump LOWARA type, assembly by means of a DC/AC inverter. The control part is provided by a computer incorporating a card DS1104 running environment Matlab/Simulink for visualization and data acquisition. These results show clearly the effectiveness of our control with a very good performance. The results obtained show the usefulness of the developed algorithm in solving the problem of degradation of PVG performance depending on the variation of climatic factors with a very good yield.

Keywords: PVWPS (PV Water Pumping System), maximum power point tracking (MPPT), open circuit method (OC), boost converter, DC/AC inverter

Procedia PDF Downloads 418
2 Integrating GIS and Analytical Hierarchy Process-Multicriteria Decision Analysis for Identification of Suitable Areas for Artificial Recharge with Reclaimed Water

Authors: Mahmoudi Marwa, Bahim Nadhem, Aydi Abdelwaheb, Issaoui Wissal, S. Najet

Abstract:

This work represents a coupling between the geographic information system (GIS) and the multicriteria analysis aiming at the selection of an artificial recharge site by the treated wastewater for the Ariana governorate. On regional characteristics, bibliography and available data on artificial recharge, 13 constraints and 5 factors were hierarchically structured for the adequacy of an artificial recharge. The factors are subdivided into two main groups: environmental factors and economic factors. The adopted methodology allows a preliminary assessment of a recharge site, the weighted linear combination (WLC) and the analytical hierarchy process (AHP) in a GIS. The standardization of the criteria is carried out by the application of the different membership functions. The form and control points of the latter are defined by the consultation of the experts. The weighting of the selected criteria is allocated according to relative importance using the AHP methodology. The weighted linear combination (WLC) integrates the different criteria and factors to delineate the most suitable areas for artificial recharge site selection by treated wastewater. The results of this study showed three potential candidate sites that appear when environmental factors are more important than economic factors. These sites are ranked in descending order using the ELECTRE III method. Nevertheless, decision making for the selection of an artificial recharge site will depend on the decision makers in force.

Keywords: artificial recharge site, treated wastewater, analytical hierarchy process, ELECTRE III

Procedia PDF Downloads 130
1 Biocontrol Effectiveness of Indigenous Trichoderma Species against Meloidogyne javanica and Fusarium oxysporum f. sp. radicis lycopersici on Tomato

Authors: Hajji Lobna, Chattaoui Mayssa, Regaieg Hajer, M'Hamdi-Boughalleb Naima, Rhouma Ali, Horrigue-Raouani Najet

Abstract:

In this study, three local isolates of Trichoderma (Tr1: T. viride, Tr2: T. harzianum and Tr3: T. asperellum) were isolated and evaluated for their biocontrol effectiveness under in vitro conditions and in greenhouse. In vitro bioassay revealed a biopotential control against Fusarium oxysporum f. sp. radicis lycopersici and Meloidogyne javanica (RKN) separately. All species of Trichoderma exhibited biocontrol performance and (Tr1) Trichoderma viride was the most efficient. In fact, growth rate inhibition of Fusarium oxysporum f. sp. radicis lycopersici (FORL) was reached 75.5% with Tr1. Parasitism rate of root-knot nematode was 60% for juveniles and 75% for eggs with the same one. Pots experiment results showed that Tr1 and Tr2, compared to chemical treatment, enhanced the plant growth and exhibited better antagonism against root-knot nematode and root-rot fungi separated or combined. All Trichoderma isolates revealed a bioprotection potential against Fusarium oxysporum f. sp. radicis lycopersici. When pathogen fungi inoculated alone, Fusarium wilt index and browning vascular rate were reduced significantly with Tr1 (0.91, 2.38%) and Tr2 (1.5, 5.5%), respectively. In the case of combined infection with Fusarium and nematode, the same isolate of Trichoderma Tr1 and Tr2 decreased Fusarium wilt index at 1.1 and 0.83 and reduced the browning vascular rate at 6.5% and 6%, respectively. Similarly, the isolate Tr1 and Tr2 caused maximum inhibition of nematode multiplication. Multiplication rate was declined at 4% with both isolates either tomato infected by nematode separately or concomitantly with Fusarium. The chemical treatment was moderate in activity against Meloidogyne javanica and Fusarium oxysporum f. sp. radicis lycopersici alone and combined.

Keywords: trichoderma spp., meloidogyne javanica, Fusarium oxysporum f.sp.radicis lycopersici, biocontrol

Procedia PDF Downloads 240