Search results for: Muluken Z. Getie
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 5

Search results for: Muluken Z. Getie

5 Parameter and Lose Effect Analysis of Beta Stirling Cycle Refrigerating Machine

Authors: Muluken Z. Getie, Francois Lanzetta, Sylvie Begot, Bimrew T. Admassu

Abstract:

This study is aimed at the numerical analysis of the effects of phase angle and losses (shuttle heat loss and gas leakage to the crankcase) that could have an impact on the pressure and temperature of working fluid for a β-type Stirling cycle refrigerating machine. First, the developed numerical model incorporates into the ideal adiabatic analysis, the shuttle heat transfer (heat loss from compression space to expansion space), and gas leakage from the working space to the buffer space into the crankcase. The other losses that may not have a direct effect on the temperature and pressure of working fluid are simply incorporated in a simple analysis. The model is then validated by reversing the model to the engine model and compared with other literature results using (GPU-3) engine. After validating the model with other engine model and experiment results, analysis of the effect of phase angle, shuttle heat lose and gas leakage on temperature, pressure, and performance (power requirement, cooling capacity and coefficient of performance) of refrigerating machine considering the FEMTO 60 Stirling engine as a case study have been conducted. Shuttle heat loss has a greater effect on the temperature of working gas; gas leakage to the crankcase has more effect on the pressure of working spaces and hence both have a considerable impact on the performance of the Stirling cycle refrigerating machine. The optimum coefficient of performance exists between phase angles of 900-950, and optimum cooling capacity could be found between phase angles of 950-980.

Keywords: beta configuration, engine model, moderate cooling, stirling refrigerator, and validation

Procedia PDF Downloads 75
4 Determinants of Multidrug-Resistant Tuberculosis in Patients Who Underwent First-Line Treatment in Addis Ababa: A Case Control Study

Authors: Selamawit Hirpa, Girmay Medhin, Belaineh Girma, Muluken Melese, Alemayehu Mekonen, Pedro Suarez, Gobena Ameni

Abstract:

Worldwide, there were 650,000 multi-drug resistant tuberculosis (MDR-TB) cases in 2010. Ethiopia is 15th among the 27 MDR-TB high-burden countries. A case control study was conducted at St. Peter Hospital and five health centers in Addis Ababa. Cases were MDR-TB patients who were in treatment at St. Peter Hospital during the study period. Controls were patients who were on first-line anti-TB treatment and were registered as cured or having completed treatment in the period 9 April 2009– 28 February 2010, in five health centers. A structured interview questionnaire was used to assess factors that could potentially be associated with the occurrence of MDR-TB. Factors that were significantly associated with MDR-TB: drug side effects during first-line treatment (adjusted odds ratio (AOR): 4.5, 95% CI; 1.9 - 10.5); treatment not directly observed by a health worker (AOR = 11.7, 95% CI; 4–34.3); and retreatment with the Category II regimen (P = 0.000).

Keywords: adherence to TB treatment, MDR-TB, TB treatment, TB treatment regimens

Procedia PDF Downloads 458
3 Electrochemical Treatment and Chemical Analyses of Tannery Wastewater Using Sacrificial Aluminum Electrode, Ethiopia

Authors: Dessie Tibebe, Muluken Asmare, Marye Mulugeta, Yezbie Kassa, Zerubabel Moges, Dereje Yenealem, Tarekegn Fentie, Agmas Amare

Abstract:

The performance of electrocoagulation (EC) using Aluminium electrodes for the treatment of effluent-containing chromium metal using a fixed bed electrochemical batch reactor was studied. In the present work, the efficiency evaluation of EC in removing physicochemical and heavy metals from real industrial tannery wastewater in the Amhara region, collected from Bahirdar, Debre Brihan, and Haik, was investigated. The treated and untreated samples were determined by AAS and ICP OES spectrophotometers. The results indicated that selected heavy metals were removed in all experiments with high removal percentages. The optimal results were obtained regarding both cost and electrocoagulation efficiency with initial pH = 3, initial concentration = 40 mg/L, electrolysis time = 30 min, current density = 40 mA/cm2, and temperature = 25oC favored metal removal. The maximum removal percentages of selected metals obtained were 84.42% for Haik, 92.64% for Bahir Dar and 94.90% for Debre Brihan. The sacrificial electrode and sludge were characterized by FT-IR, SEM and XRD. After treatment, some metals like chromium will be used again as a tanning agent in leather processing to promote a circular economy.

Keywords: electrochemical, treatment, aluminum, tannery effluent

Procedia PDF Downloads 51
2 A Systematic Review and Meta-Analysis of Diabetes Ketoacidosis in Ethiopia

Authors: Addisu Tadesse Sahile, Mussie Wubshet Teka, Solomon Muluken Ayehu

Abstract:

Background: Diabetes is one of the common public health problems of the century that was estimated to affect one in a tenth of the world population by the year 2030, where diabetes ketoacidosis is one of its common acute complications. Objectives: The aim of this review was to assess the magnitude of diabetes ketoacidosis among patients with type 1 diabetes in Ethiopia. Methods: A systematic data search was done across Google Scholar, PubMed, Web of Science, and African Online Journals. Two reviewers carried out the selection, reviewing, screening, and extraction of the data independently by using a Microsoft Excel Spreadsheet. The Joanna Briggs Institute's prevalence critical appraisal tool was used to assess the quality of evidence. All studies conducted in Ethiopia that reported diabetes ketoacidosis rates among type 1 diabetes were included. The extracted data was imported into the comprehensive meta-analysis version 3.0 for further analysis. Heterogeneity was checked by Higgins’s method, whereas the publication bias was checked by using Beggs and Eggers’s tests. A random-effects meta-analysis model with a 95% confidence interval was computed to estimate the pooled prevalence. Furthermore, subgroup analysis based on the study area (Region) and the sample size was carried out. Result and Conclusion: After review made across a total of 51 articles, of which 12 articles fulfilled the inclusion criteria and were included in the meta-analysis. The pooled prevalence of diabetes ketoacidosis among type 1 diabetes in Ethiopia was 53.2% (95%CI: 43.1%-63.1%). The highest prevalence of DKA was reported in the Tigray region of Ethiopia, whereas the lowest was reported in the Southern region of Ethiopia. Concerned bodies were suggested to work on the escalated burden of diabetes ketoacidosis in Ethiopia.

Keywords: DKA, Type 1 diabetes, Ethiopia, systematic review, meta-analysis

Procedia PDF Downloads 16
1 Intensification of Heat Transfer Using AL₂O₃-Cu/Water Hybrid Nanofluid in a Circular Duct Using Inserts

Authors: Muluken Biadgelegn Wollele, Mebratu Assaye Mengistu

Abstract:

Nanotechnology has created new opportunities for improving industrial efficiency and performance. One of the proposed approaches to improving the effectiveness of temperature exchangers is the use of nanofluids to improve heat transfer performance. The thermal conductivity of nanoparticles, as well as their size, diameter, and volume concentration, all played a role in influencing the rate of heat transfer. Nanofluids are commonly used in automobiles, energy storage, electronic component cooling, solar absorbers, and nuclear reactors. Convective heat transfer must be improved when designing thermal systems in order to reduce heat exchanger size, weight, and cost. Using roughened surfaces to promote heat transfer has been tried several times. Thus, both active and passive heat transfer methods show potential in terms of heat transfer improvement. There will be an added advantage of enhanced heat transfer due to the two methods adopted; however, pressure drop must be considered during flow. Thus, the current research aims to increase heat transfer by adding a twisted tap insert in a plain tube using a working fluid hybrid nanofluid (Al₂O₃-Cu) with a base fluid of water. A circular duct with inserts, a tube length of 3 meters, a hydraulic diameter of 0.01 meters, and tube walls with a constant heat flux of 20 kW/m² and a twist ratio of 125 was used to investigate Al₂O₃-Cu/H₂O hybrid nanofluid with inserts. The temperature distribution is better than with conventional tube designs due to stronger tangential contact and swirls in the twisted tape. The Nusselt number values of plain twisted tape tubes are 1.5–2.0 percent higher than those of plain tubes. When twisted tape is used instead of plain tube, performance evaluation criteria improve by 1.01 times. A heat exchanger that is useful for a number of heat exchanger applications can be built utilizing a mixed flow of analysis that incorporates passive and active methodologies.

Keywords: nanofluids, active method, passive method, Nusselt number, performance evaluation criteria

Procedia PDF Downloads 35